Accuracy requirements Clause Samples
The Accuracy Requirements clause sets standards for the correctness and reliability of information or data provided under an agreement. It typically outlines the level of precision expected, the types of information subject to these standards, and may specify procedures for verifying accuracy or addressing errors. By establishing clear expectations for accuracy, this clause helps prevent disputes arising from misinformation and ensures that both parties can rely on the data exchanged.
Accuracy requirements. The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times:
Metering Type 1 ( Metering of circuits rated greater than 100MVA) Metering Type 2 (Metering of circuits not exceeding 100MVA) Metering Type 3 (Metering of circuits not exceeding 10MVA)
Accuracy requirements. All standards, procedures and equipment used by the Engineer’s Surveyor shall be such that the results of the survey will be in compliance with Board Rule 663.15 as promulgated by the TBPLS.
Accuracy requirements. Overall accuracy The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times:
Accuracy requirements. 4.2.1 Overall accuracy: The overall accuracy of the energy measurements at or referred to at the Defined Metering Point shall at all times be within the limits of error as shown:-
4.2.1.1 Active Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% * 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± 0.5% ± 0.7% ± 1.5% ± 1.0% Superseded * This requirement shall only apply where the energy transfers to be measured by the Import Meter and/or the Export Meter during normal operating conditions is such that measured current will be below 5% of the Rated Measurement Current (excluding zero) for periods equivalent to 10% or greater per annum.
Accuracy requirements. The overall accuracy of the electricity measurements in respect of each Meter must be within the following limits of error at all times: Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± ± ± ± 1.0% 0.5% 0.7% 1.5% Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± ± ± ± 2.0% 1.0% 1.5% 2.5% Condition Limits of error at stated system power factor Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% 120% to 10% inclusive 1 1 0.5 lag and 0.8 lead ± ± ± 2.5% 1.5% 2.0%
Accuracy requirements. The Data Provider shall ensure that the accuracy of aeronautical data is as specified in the Aeronautical Data Catalogue [ATM/ANS.OR.A.085 (b)(1)] [ADR.OPS.A.010 (b)].
Accuracy requirements. The Data Provider shall ensure that the accuracy of aeronautical data is as specified in the Aeronautical Data Catalogue [ATM/ANS.OR.A.085 (b)(1)] [ADR.OPS.A.010 (b)]. The Data Provider shall ensure that the resolution of aeronautical data is commensurate with the actual data accuracy, i.e. the resolution should be sufficient to meet the accuracy of the data [ATM/ANS.OR.A.085 (b)(4)] [ADR.OPS.A.010 (d)]. When originating, processing or transmitting data to the Data Receiver, the Data Provider shall ensure that digital data error detection techniques are used during the transmission and storage of aeronautical data, in order to support the applicable data integrity levels [ATM/ANS.OR.A.085 (b)(2) & (3)] [ADR.OPS.A.010 (c) and A.025]. The Data Provider ensures the traceability of the Data from origination (generation) to transmission to the Data Receiver. The Data Receiver ensures the traceability of the Data throughout the data process from receipt from the Data Provider up to publication/distribution. [ATM/ANS.OR.A.085 (b)(5)] [ADR.OPS.A.010 (e)] Traceability is supported by maintaining the metadata [GM1 ATM/ANS.OR.A.085 (b)(5)] [GM1 ADR.OPS.A.010 (e)]. Data records shall be kept in accordance with the record keeping requirements of the amended CIR (EU) 2017/373 [ATM/ANS.OR.B.030] [ADR.OR.D.035 and ADR.OR.F.080]. Records of Data provided to [entity receiving data] shall be kept for at least [specify requirements] following the end of that validity period.
Accuracy requirements. All surveying shall be based on the control network established under separate contract. The State will provide control monument datasheets to the Engineer’s Surveyor. All standards, procedures and equipment used by the Engineer’s Surveyor shall be such that the results of the survey will be in compliance with Board Rule 663.15 as promulgated by the TBPLS. DocuSign Envelope ID: C8AF675D-2526-41B2-938D-3D337F7E3DEC
Accuracy requirements. 4.2.1 Overall accuracy: The overall accuracy of the energy measurements at or referred to the Defined Metering Point shall at all times be within the limits of error as shown:
4.2.1.1 Active Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive Below 10% to 5% Below 5% to 1% * 120% to 10% inclusive 1 1 1 0.5 lag and 0.8 lead ± 1.0% ± 1.5% ± 2.5% ± 2.0% Superseded * This requirement shall only apply where the energy transfers to be measured by the Import Meter and/or the Export Meter during normal operating conditions is such that the measured current will be below 5% of the Rated Measuring Current (excluding zero) for periods equivalent to 10% or greater per annum.
4.2.1.2 Reactive Energy CONDITION LIMIT OF ERRORS AT STATED SYSTEM POWER FACTOR Current expressed as a percentage of Rated Measuring Current Power Factor Limits of Error 120% to 10% inclusive 120% to 20% inclusive Zero 0.866 lag and 0.866 lead ± 4.0% ± 5.0% Superseded These limits of error for both Sections 4.2.1.1 and
Accuracy requirements. The overall accuracy of the energy measurements shall at all times be within the limits of error specified in SI792 Regulation 8 pertaining to Schedule 7 of the Act. Meters where certified shall be certified in accordance with Schedule 7 of the Act.