Autotransformers and Reactors Clause Samples

Autotransformers and Reactors. Autotransformers and reactors will be immersed in oil for outdoor installation, cooled by natural circulation of oil and air (ONAN) and ventilation (ONAF) with the following characteristics: Primary winding voltage 500 / √3 kV Secondary winding voltage 220 / √3 kV Tertiary winding voltage -- kV (*) Type Single-phase autotransformer Rated power per single-phase unit 250 MVA Rated power of the three-phase bank 750 MVA Plus one reserve single-phase unit Refrigeration ONAF Neutral connection Solid to earth Accessories Bushing type current transformers Primary winding voltage 500 / √3 kV 500 / √3 kV 500 / √3 kV Type Single-phase Single-phase Single-phase Rated power per single-phase unit 33 MVAr (**) 30 MVAr (**) 33 MVAr (**) Rated Power of the three-phase bank 100 MVAr (**) Plus one reserve unit 90 MVAr (**) Plus one reserve unit 100 MVAr (**) Plus one reserve unit Refrigeration ONAN ONAN ONAN Neutral connection Solid to earth Neutral reactor (**) Neutral reactor (**) Accessories Bushing type current transformers Bushing type current transformers Bushing type current transformers (*) (*) Final values will be defined by the Concessionaire and approved in the Preoperative Study by COES. (**) Number and size of components, as well as basic specifications of the reactive compensation equipment shall be defined by the Concessionaire and approved by COES-SINAC in the Pre-Operative Study. They will consist mainly of the following components:
Autotransformers and Reactors. Autotransformers and reactors will be immersed in oil for outdoor installation, cooled by natural circulation of oil and air (ONAN) and ventilation (ONAF) with the following characteristics: Primary winding voltage 500 / √3 kV Secondary winding voltage 220 / √3 kV Tertiary winding voltage -- kV (*) Type Single-phase autotransformer Rated power per single-phase unit 250 MVA Rated power of the three-phase bank 750 MVA Plus one reserve single-phase unit Refrigeration ONAF Neutral connection Solid to earth Accessories Bushing type current transformers Primary winding 500 / √3 kV 500 / √3 kV 500 / √3 kV Type Single-phase Single-phase Single-phase Rated power per single-phase unit 33 MVAr (**) 30 MVAr (**) 33 MVAr (**) Rated Power of the three-phase bank 100 MVAr (**) Plus one reserve unit 90 MVAr (**) Plus one reserve unit 100 MVAr (**) Plus one reserve unit Refrigeration ONAN ONAN ONAN Neutral connection Solid to earth Neutral reactor (**) Neutral reactor (**) Accessories Bushing type current transformers Bushing type current transformers Bushing type current transformers (*) (*) Final values will be defined by the Concessionaire and approved in the Preoperative Study by COES. (**) Number and size of components, as well as basic specifications of the reactive compensation equipment shall be defined by the Concessionaire and approved by COES-SINAC in the Pre-Operative Study. They will consist mainly of the following components:

Related to Autotransformers and Reactors

  • Drainage Systems (1) Clear culvert inlets, outlets, and sediment catching basins. (2) Maintain waterbars, drainage dips, and other water diversion measures. (3) During active use, patrol and maintain functional drainage. (4) Repair damaged culvert ends.

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If WCS chooses to subtend a Verizon access Tandem, WCS’s NPA/NXX must be assigned by WCS to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 WCS shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from WCS’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office WCS utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow WCS’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • COVID-19 Vaccinations Contractor understands, acknowledges, and agrees that, pursuant to Article II of the General Appropriations Act, none of the General Revenue Funds appropriated to the Department of State Health Services (DSHS) may be used for the purpose of promoting or advertising COVID-19 vaccinations in the 2024-25 biennium. It is also the intent of the legislature that to the extent allowed by federal law, any federal funds allocated to DSHS shall be expended for activities other than promoting or advertising COVID-19 vaccinations. Contractor represents and warrants that it is not ineligible, nor will it be ineligible during the term of this Contract, to receive appropriated funding pursuant to Article II.

  • Welding Welding and use of cutting torches or cutoff saws will be permitted only in areas that have been cleared or are free of all material capable of carrying fire. Flammable debris and vegetation must be removed from within a minimum 10-foot radius of all welding and cutting operations. A shovel and a 5-gallon standard backpack water container filled and with handpump attached shall be immediately available for use in the event of a fire start. C8.64 – DEBARMENT AND SUSPENSION CERTIFICATION (3/18). Pursuant to 2 CFR 180 and 2 CFR 417, Purchaser shall certify and obtain certifications from its Subcontractors regarding debarment, suspension, ineligibility, and voluntary exclusion, including additional Subcontractors obtained after award of this contract. “Subcontractors” are participants in lower tier covered transactions. Purchaser may rely upon a certification of a prospective Subcontractor that it is not proposed for debarment under 48 CFR 9.4, debarred, suspended, ineligible, or voluntarily excluded from participating in covered transactions or timber sales, unless Purchaser knows that the certification is erroneous. Purchaser shall keep the certifications of its Subcontractors on file until timber sale Termination Date and any extensions thereof, and will provide a copy at the written request of Contracting Officer. Nothing contained in the foregoing shall be construed to require establishment of a system of records in order to render in good faith the certification required by this Subsection. The knowledge and information of Purchaser is not required to exceed that which is normally possessed by a prudent person in the ordinary course of business dealings. If Purchaser knowingly enters into a timber sale transaction with a person who is proposed for debarment under 48 CFR 9.4, suspended, debarred, ineligible, or voluntarily excluded from participation in covered transactions or timber sales, in addition to other remedies available to the Government, Forest Service may pursue available remedies, including suspension and/or debarment. Contracting Officer shall provide a copy of Forms AD-1047 Certification Regarding Debarment, Suspension and Other Responsibility Matters – Primary Covered Transactions and AD-1048 Certification Regarding Debarment, Suspension, Ineligibility and Voluntary Exclusion – Lower Tier Covered Transactions to the Purchaser. Purchaser shall complete form AD-1047 and provide to the Contracting Officer upon request. Purchaser shall require each subcontractor to complete form AD-1048 and provide to the Contracting Officer upon request.