Common use of Configuration Software Description Clause in Contracts

Configuration Software Description. The MODBUS data registers of the Gateway need to be configured prior to use. The configuration program “Trs Programmer.exe” can be found on the disk or CD ROM on the back cover of this manual will configure the data register as follows: - Assign the Input Register function – Analog or Discrete - Assign wireless Digital Output (Coil) Register function - Assign wireless Analog Output (Holding) Register function - Assign the register address - Assign the Wireless Sensor ID and transmission channel - Assign the data type • The MOD9200 Transceiver can have up to 100 (addresses 0 to 99) data registers configured to be either Analog or Discrete, 50 digital outputs and 50 analog outputs. • Error registers are directly mapped to the data registers + 400 (addresses 400 to 499). For example errors for data register 55 will be in error register 455.

Appears in 1 contract

Sources: License Agreement

Configuration Software Description. The MODBUS data registers of the Gateway need to be configured prior to use. The configuration program “Trs Programmer.exeSETUP.exe” can be found on the disk or CD ROM on the back cover of this manual will configure the data register as follows: - Assign the Input Register function – Analog or Discrete - Assign wireless Digital Output (Coil) Register function - Assign wireless Analog Output (Holding) Register function - Assign the register address - Assign the Wireless Sensor ID and transmission channel - Assign the data type • The MOD9200 Transceiver can have up to 100 (addresses 0 to 99) data registers configured to be either Analog or Discrete, 50 digital outputs and 50 analog outputs. • Error registers are directly mapped to the data registers + 400 (addresses 400 to 499). For example errors for data register 55 will be in error register 455.

Appears in 1 contract

Sources: License Agreement

Configuration Software Description. The MODBUS data registers of the Gateway need to be configured prior to use. The configuration program “Trs Programmer.exeSETUP.exe” can be found on the disk or CD ROM on the back cover of this manual will configure the data register as follows: - Assign the Input Register function – Analog or Discrete - Assign wireless Digital Output (Coil) Register function - Assign wireless Analog Output (Holding) Register function - Assign the register address - Assign the Wireless Sensor ID and transmission channel - Assign the data type • The MOD9200 Transceiver can have up to 100 (addresses 0 to 99) data registers configured to be either Analog or Discrete, 50 digital outputs and 50 analog outputs. • Error registers are directly mapped to the data registers + 400 (addresses 400 to 499). For example example, errors for data register 55 will be in error register 455.

Appears in 1 contract

Sources: License Agreement