Unbundled Sub-Loop Feeder 2.8.4.1 Unbundled Sub-Loop Feeder (USLF) provides connectivity between BellSouth's central office and cross-box (or other access point) that serves an end user location. 2.8.4.2 USLF utilized for voice traffic can be configured as 2-wire voice (USLF-2W/V) or 4-wire voice (USLF-4W/V). 2.8.4.3 USLF utilized for digital traffic can be configured as 2-wire ISDN (USLF-2W/I); 2-wire Copper (USLF-2W/C); 4-wire Copper (USLF-4W/C); 4-wire DS0 level loop (USLF-4W/D0); or 4-wire DS1 and ISDN (USLF-4W/DI). 2.8.4.4 USLF will provide access to both the equipment and the features in the BellSouth central office and BellSouth cross box necessary to provide a 2W or 4W communications pathway from the BellSouth central office to the BellSouth cross- box. This element will allow for the connection of Global Connection’s loop distribution elements onto BellSouth's feeder system.
User Generated Content 10.1 As a user to this website, You may be allowed to post any User Generated Content (“User Content”) and You agree, by submitting your contribution, you ▇▇▇▇▇ ▇▇ Group a perpetual, royalty-free, non-exclusive, sublicensable right and license to use, reproduce, edit, modify, adapt, publish, translate, create derivate works from, distribute, perform, play, make available to the public, and exercise all copyright and publicity rights with respect to your contribution worldwide and/or to incorporate your contribution in other works in any media, now known or later developed, for the full terms of any rights that may exist in your contribution. 10.2 You also hereby grant other user of TM Website a non-exclusive license to access your User Content through the access and/or use of TM Website, and to use such User Content only as permitted through the functionality of TM Website. 10.3 You understand and agree that TM may retain and store, but not display, distribute, or perform, server copies of User Content that has been removed or deleted. The above licenses granted to TM, by You in User Content is irrevocable. 10.4 Further to the foregoing paragraph, by submitting your User Content to us, You warrant that:- (a) your User Content is your own original work or have the necessary license, rights, consents, and permissions to use and authorize us to use all patent, trademark, trade secret, copyright or other proprietary rights in and to any and all User Content to enable TM to use of the User Content in the manner required by us and that you have the right to make it available to us for all the purposes specified above; (b) your User Content is not defamatory, threatening, injurious, insulting character, offensive, abusive, offensive on moral, menacing, religious or political grounds, impair your confidentiality obligations; (c) your User Content does not infringe the law; (d) You shall be solely responsible for your own User Content and the consequences of posting or publishing them; (e) You will not submit material that is copyrighted, protected by trade secret or otherwise subject to third party proprietary rights, including privacy and publicity rights, unless you are the owner of such rights or have permission from their rightful owner to post material and to grant us all of the license rights granted herein; and/or (f) waive any moral rights in your User Content for the purposes of its submission to and publication in TM Website and the purposes specified above. 10.5 You understand that whether or not such User Content is posted, TM does not guarantee any confidentiality with respect to any User Content. TM does not endorse any User Content or any opinion, recommendation, or advice expressed therein, and expressly disclaims any and all liability in connection with User Content. We do not permit activities which will infringe any Intellectual Property Rights including copyright and we will remove all infringing contents and User Content upon notification that such Content or User Content infringes on another’s Intellectual Property Rights. We further reserve the right to remove any Content or User Content without prior notice. 10.6 You understand and agree that we may review and delete any User Content that you posted at any time without notice, without liability and for any reason whatsoever, especially if you breach the terms and conditions herein. 10.7 We reserve the right to investigate and take appropriate legal action, in our sole discretion, against You for the User Content especially if it violates TM policy and report you to the Appropriate Authority.
Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). The UCL-D will be offered in two versions - Short and Long. 2.4.2.2 A short UCL-D (18,000 feet or less) is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 ohms of resistance. 2.4.2.3 The long UCL-D (beyond 18,000 feet) is provisioned as a dry copper twisted pair longer than 18,000 feet and may have up to 12,000 feet of bridged tap and up to 2800 ohms of resistance. 2.4.2.4 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Granite. 2.4.2.5 These loops are not intended to support any particular services and may be utilized by Granite to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.2.6 BellSouth will make available the following UCL-Ds:
Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame (MDF) to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (DAMLs), and may have up to 6,000 feet of bridged tap between the End User’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For Loops less than 18,000 feet and with less than 1300 Ohms resistance, the Loop will provide a voice grade transmission channel suitable for Loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Makeup (LMU) process is not required to order and provision the UCL-ND. However, CBX One-Stop can request LMU for which additional charges would apply. 2.4.3.3 For an additional charge, BellSouth also will make available Loop Testing so that CBX One-Stop may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit A of this Attachment. 2.4.3.4 UCL-ND Loops are not intended to support any particular service and may be utilized by CBX One-Stop to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. The UCL- ND will include a NID at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.3.5 OC will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. OC-TS does not apply to this product. 2.4.3.6 CBX One-Stop may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove excessive bridged taps and/or load coils from any copper Loop within the BellSouth network. Therefore, some Loops that would not qualify as UCL-ND could be transformed into Loops that do qualify, using the ULM process.
Access Toll Connecting Trunk Group Architecture 9.2.1 If WCS chooses to subtend a Verizon access Tandem, WCS’s NPA/NXX must be assigned by WCS to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 WCS shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from WCS’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office WCS utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow WCS’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.