Dimensional Requirements Sample Clauses

The Dimensional Requirements clause sets out the specific measurements and tolerances that products, materials, or components must meet under a contract. It typically details the acceptable ranges for length, width, height, or other relevant dimensions, and may reference industry standards or project specifications. By clearly defining these parameters, the clause ensures that all parties have a mutual understanding of the physical expectations for deliverables, thereby reducing the risk of disputes over non-conforming goods or work.
Dimensional Requirements. Confirms that the Property is in compliance with all dimensional requirements of the zoning code, including minimum lot area, maximum building height, maximum floor area ratio and setback or buffer requirements.
Dimensional Requirements i. Table 20.50.020(3) is modified as follows: Base Height shall be 80 feet.
Dimensional Requirements. The Property shall be subject to the following dimensional requirements: A. Maximum Building Height: 45 feet B. Perimeter Setbacks: 25 feet C. Internal Property Line Setbacks: 10 feet D. Maximum number of building lots: 2 lots E. Minimum Lot Size: .75 acre F. Minimum Lot Width: 150 feet G. Maximum Building Coverage: .20 FAR H. Minimum Open Space: 30% I. All other dimensional criteria shall be as set forth on the Conceptual Development Plan attached as Exhibit “B”. Any dimensional standard not set forth on Exhibit “B” shall conform to the requirements set forth in the CC zoning district.
Dimensional Requirements. The following dimensional requirements shall apply to the PROPERTY as a whole, and not additionally to individual lots (if any) within the PROPERTY: a. Maximum impervious surface ratio: Eighty (80) percent; b. Maximum building height: Ninety (90) feet; c. Minimum front yard landscaped buffer: Twenty
Dimensional Requirements. ▇▇▇▇▇▇ must have a top width to depth ratio of the cross-section equal to or greater than 6:1 or side slopes equal to or greater than 3:1 (horizontal to vertical).
Dimensional Requirements. The Property shall be permitted to be developed in accordance with the criteria with respect to minimum parcel sizes, open space, population densities, building intensities, setbacks, height, parking, buffers, fencing, signage, impervious coverage, and other dimensional requirements or building development standards as applicable to the Medium Density Residential (MDR) District and the Cluster Subdivision Overlay as set forth in the UDO.
Dimensional Requirements. Confirms that the Borrowing Base Properties are in compliance with all dimensional requirements of the zoning code, including minimum lot area, maximum building height, maximum floor area ratio and setback or buffer requirements.
Dimensional Requirements. Lot dimensions and configuration within the Property are generally depicted on the CDP. The lot sizes and configurations shall comply with the minimum dimensional requirements described below. The lot dimensions and areas shown on Exhibit “B” may be adjusted during the final subdivision process. Setbacks: Front: 20 feet Rear: 15 feet Side: n/a Side Corner: n/a Minimum Lot Size: Width: 22 feet Depth: 85 feet Area: 1,650 square feet Maximum Building Height: 35 feet (as measured form the grade to the mid-point of the trusses) Minimum Building Separation: 25 feet Minimum Open Space: 20% Maximum Impervious Area: 80% Maximum Building Coverage: 60% Site Development Requirements for Overall Property Maximum Building Coverage: 40% Minimum Open Space: 60% (20% of which shall be common open space)
Dimensional Requirements. Minimum Lot Area: 15,000 square feet Minimum Lot Width: 100 feet Maximum Building Height: 45 feet Maximum Lot Coverage: 70% Minimum Building Separation: 10 feet Minimum Front Setback: Equal to the required right-of-way landscape buffer in Chapter 13 of the Land Development Code Minimum Rear Setback: 25 Feet (Non-residential building setbacks adjoining residential zoning shall be equal to Minimum Side Setback: 10 Feet
Dimensional Requirements. Lot dimensions and configurations within the Property are generally depicted on the CDP. The lot sizes and configurations shall comply with the minimum dimensional requirements described below. The lot dimensions and areas shown on Exhibit “B” may be adjusted during the final subdivision process. The total number of residential units in the development shall not exceed 254 dwelling units or a gross project density of 7.34 dwelling units per acre. 1. Single Family Lot Development Requirements a. Setbacks i. Front: 20 feet ii. Rear: 15 feet iii. Side: 5 feet iv. Side Corner: 10 feet b. Minimum Lot Size i. Width: 40 feet ii. Depth: 110 feet c. Maximum Building Height: 35 feet (measured from the grade to the mid-point of the trusses) d. Minimum Open Space: 32% e. Maximum Impervious Area: 68% f. Maximum Building Coverage: 55% 2. Townhome Lot Development Requirements i. Front: 20 feet ii. Rear: 15 feet iii. Side: n/a iv. Side Corner: n/a g. Minimum Lot Size i. Width: 20 feet ii. Depth: 85 feet