Dispersion Model) Clause Samples

Dispersion Model). Table 4.1 describes the input parameters that were used in the Runspec and PDM for the MOVES component of the analysis. 13 EPA released a new version of MOVES on October 7, 2014 as ▇▇▇▇▇▇▇▇▇. Future revisions to the PA and TSD should make use of this updated version of MOVES or any subsequent version at the time of update.
Dispersion Model). The inputs for the dispersion modeling followed EPA’s 1992 Guidance for CO determinations using CAL3QHC (version 04244) and were consistent with the approach used by the Federal Highway Administration (FHWA) Carbon Monoxide (CO) Categorical Hot-Spot Finding (FHWA, February 2014) for intersections. As for emissions modeling, dispersion modeling was performed using conservative underlying assumptions and, in many cases, worst-case inputs and assumptions. These inputs and assumptions are outlined below:  As a conservative assumption, the wind speed was set to 1.0 m/s (the lower limit of CAL3QHC meaningful input).  Wind direction was modeled every ten degrees from 0 to 350 degrees.  A mixing height of 1000 m was used, consistent with standard modeling procedures. Sensitivity testing has shown that due to the close proximity of the receptors, mixing height has negligible influence on dispersion analysis.  For urban modeling, a surface roughness (z0) of 108 cm was used, corresponding to a single family residential setting. The single family residential setting is the least rough setting for an urban environment and is conservative. The recommended surface roughness in urban areas can vary from 108 to 370 cm. For rural areas, a surface roughness of 1.0 cm was used, which corresponds to a moderately short grass height (6-8 cm) as identified in prairie grass.16 Shorter grass heights are unlikely to be found in most rural locations.  The 1992 EPA CO Guidelines specifies a stability class of D (neutral) for urban areas and E (stable) for rural areas. These guidelines were applied in the model.  Receptor Placement o Freeways and Arterials:  Receptors were modeled per the CAL3QHC and 1992 EPA Guidance. For both freeways and arterials, receptors were placed on both sides of the roadway extending out to 295 feet from the roadway and were modeled to establish decreasing CO concentrations with distance.  For freeways, receptors were located beginning at 30 feet from the outside lane to account for off-road safety clearance.  For arterials, receptors were located beginning at 10 feet from roadway edge (where the general public has access and is within the limitations of the model to predict valid concentrations). o Intersections and Interchanges:  Receptors were modeled per the CAL3QHC and 1992 EPA Guidance and began at 10 feet from roadway edge.  A grid of receptors was used in each quadrant to ensure the worst case concentrations were identified. The grid spaci...

Related to Dispersion Model)

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4. 5.7.2 BellSouth shall make available the following channelization systems and interfaces: 5.7.2.1 DS1 Channelization System: channelizes a DS1 signal into a maximum of twenty- four (24)

  • OPEN SOURCE COMPONENTS The DS Offerings may include open source components. Whenever notices (such as acknowledgment, copies of licenses or attribution notice) are required by the original licensor, such notices are included in the Documentation of the DS Offerings. Moreover, some open source components may not be distributed and licensed under the terms of the Agreement but under the terms of their original licenses as set forth in the Documentation of the DS Offerings themselves. Source code for open source software components is available upon request. Except for components mentioned in the section EXCLUSIONS below, the warranty and indemnification provided by DS under the Agreement apply to all open source software components and shall be provided by DS and not by the original licensor, but only for the use of the DS Offerings that is in compliance with the terms of the Agreement, and in conjunction with the DS Offerings. The original licensors of said open source software components provide them on an “as is” basis and without any liability whatsoever to Customer.

  • Solution The Supplier’s contractually committed technical approach for solving an information technology business objective and associated Requirements as defined and authorized by the scope of the Contract or any order or Statement of Work issued under the Contract. Solution means all Supplier and Supplier’s third-party providers’ components making up the Solution, including but not limited to Software, Product, configuration design, implementation, Supplier-developed interfaces, Services and Work Product.

  • Hepatitis B Vaccine Where the Hospital identifies high risk areas where employees are exposed to Hepatitis B, the Hospital will provide, at no cost to the employees, a Hepatitis B vaccine.

  • Geometric visibility The visibility of the illuminating surface, including its visibility in areas which do not appear to be illuminated in the direction of observation considered, shall be ensured within a divergent space defined by generating lines based on the perimeter of the illuminating surface and forming an angle of not less than 5° with the axis of reference of the headlamp.