Door Frames Sample Clauses

The 'Door Frames' clause defines the requirements and standards for the installation, materials, and finishing of door frames within a construction or renovation project. It typically specifies the types of materials to be used (such as wood, metal, or composite), the dimensions and tolerances, and the methods for securing frames to walls. For example, it may require that all door frames be fire-rated or that they match certain aesthetic criteria. The core function of this clause is to ensure consistency, safety, and quality in the installation of door frames, thereby preventing disputes or issues related to improper or substandard work.
Door Frames. Painted Hollow Metal Doorframe, Full height in most corridors verify in field. 3’- 0”x 7’-0” rated solid core wood, paint grade. Suite Entry doors to have Schlage L9453 STYLE 06 in bright Stainless Steel Finish with ADA closer mounted on the tenant side of the doorframe. Tenant doors to have Lever ▇▇▇▇▇▇ ▇▇▇▇▇▇▇▇ ▇▇▇▇▇▇▇, ▇▇▇▇▇▇ ▇▇▇▇▇▇▇ Newport, CL,3800 series. Finish to be satin chrome. Locks to be keyed by building Master by Lock Technologies. Contact ▇▇▇ ▇▇▇-▇▇▇-▇▇▇▇. Metroplex II has a D4 Keyway. Landlord to approve all glass doors. Sidelights to be integral.
Door Frames. Rates for timber door frames shall be deemed to include for approved mild steel stay pegs in floors and hoop-iron clamps to walls, including holes, building in, etc Particle board shall comply with the following specifications:
Door Frames. All to be of 4" x 2.5" Malaysia ▇▇▇.Doors to be water proof phenol bonded flush door.
Door Frames. Painted Hollow Metal Doorframe, Full height in most corridors verify in field,
Door Frames. 1. All door frames to be Timely pre-finished frames. Finish to match storefronts unless otherwise noted. All frames shall be provided with a one (1) hour fire
Door Frames. Natural Anodised Aluminium door frames, framing ,cutting, pinning lugs to aluminium frame including glazing with 6.38mm thick solarshield safety glass all ironmongery as specified by the Architect A 900mm wide x 2000mm high door frame with hinged opening as per Architects' details; complete with 6.38 mm laminated shutter proof solarshield glass - 001D01 No 1 ,cutting, pinning lugs to aluminium frame including glazing with 6.38mm thick solarshield safety glass all ironmongery as specified by the Architect B Aluminium window frame for opening of 3230 mm width x 1200 mm height with overall and complete with suitable locking mechanism all as per Architects' details; complete with 6.38 mm laminated shutter proof solarshield glass - 001W01 No 1 C Aluminium window frame for opening of 1200 mm width x 600 mm height with overall and complete with suitable locking mechanism all as per Architects' details; complete with 6.38 mm laminated shutter proof solarshield glass - 002W01, 002W02 No 1 GUARD HOUSE METAL WORK METAL WORK Total Brought Forward from Page No. GUARD HOUSE METAL WORK -4/9- -4/10- Amount K PLUMBING INSTALLATIONS ( ALL PROVISIONAL)
Door Frames a. Refer to Part W SABS 0400 and SANS 10400. b. All external door frames to be Timber as per door schedule, with standard steel striker plate, to suit a plastered 230mm wall, with rebate to suit floor finish (i.e. with screed and approved floor finish) c. All internal door frames to be 1.0mm SABS standard steel as per door schedule with standard steel striker plate, to suit a plastered 90mm internal wall, to suit floor finish (i.e. with screed and approved floor finish).
Door Frames. Extruded aluminum with bronze anodized finish. International Aluminum Corporation – Waxahachie, Texas 3- 3/4” No. 5 bronze anodized or equal. ▇▇▇▇▇▇▇ (1 1/2 pair) FBB 179-5” X 4 -12”. Tower I has three hinges. Tower II & III have four. Schlage L9000 Series, 625 handle Schlage L9000 Series, 625 Handle Ives floor stop BP 436B U.S. Lock 7600 with Duranodic To the ceiling with 2- 1/2” 25 gauge metal studs 24” o.c. to ceiling (approximately 9’-0”) with single layer of 5/8” drywall on each side. 4” vinyl base by V.P.I. Johnsonite or equal. Grid: “▇▇▇▇ Fineline” or equal. U.S. GYP – 2’X2’ lay in tile. 2’ X 4’ with 3 lamp parabolic type w/ three 32 watt T8 fluorescent tube lamps with 277V electronic ballasts, by Columbia Lighting Corp. P4-24G4363-7, Parabolume, 3” Natural anodized louver, fixtures shall be installed with an average coverage of 75 sq. feet. Unit installation costs shall be based on 24 fixtures per circuit. Building standard switches are ▇▇▇▇▇▇▇ 1201-1. Duallite model Luminex universal exit sign (red letters with white housing and internal emergency backup).
Door Frames. Pre finished or hollow metal frame, finish per building standard. Fire rated as required by applicable codes. All non-rated frames to have ‘silencer pads’ at strike side stop.
Door Frames. Two (2) coats of oil-based semi-gloss. If reused and have factory anodized finish, shall be in new condition.