Common use of Engineer’s Authority Clause in Contracts

Engineer’s Authority. 29.1 The Engineer shall act as the Owner's representative during the construction period, shall decide questions which may arise as to quality and acceptability of materials furnished and work performed, and shall interpret the intent of the contract documents in a fair and unbiased manner. The Engineer will make visits to the site and determine if the work is proceeding in accordance with the contract documents. 29.2 The Contractor will be held strictly in the intent of the contract documents in regards to the quality of materials, workmanship, and execution of the work. Inspections may be made at the factory or fabrication plant of the source of material supply. 29.3 The Engineer will not be responsible for the construction means, controls, techniques, sequence, procedures, or constuction safety. 29.4 The Engineer shall promptly make decision relative to interpretation of the contract documents.

Appears in 1 contract

Sources: Construction Contract

Engineer’s Authority. 29.1 27.1 The Engineer shall act as the Owner's representative during the construction period, . He shall decide questions which may arise as to quality and acceptability of materials furnished and work Work performed, and . He shall interpret the intent of the contract documents Contract Documents in a fair and unbiased manner. The Engineer will make visits to the site and determine if the work Work is proceeding in accordance with the contract documentsContract Documents. 29.2 27.2 The Contractor will be held strictly in to the intent of the contract documents Contract Documents in regards regard to the quality of materials, workmanship, workmanship and execution of the workWork. Inspections may be made at the factory or fabrication plant of the source of material supply. 29.3 27.3 The Engineer will not be responsible for the construction means, controls, techniques, sequencesequences, procedures, or constuction construction safety. 29.4 27.4 The Engineer shall promptly make decision decisions relative to interpretation of the contract documentsContract Documents.

Appears in 1 contract

Sources: Agreement for Design, Installation, and Commissioning of Energy Conservation Facilities

Engineer’s Authority. 29.1 27.1 The Engineer engineer shall act as the Ownerowner's representative during the construction period, . He shall decide questions which may arise as to quality and acceptability of materials furnished and work performed, and . He shall interpret the intent of the contract documents in a fair and unbiased manner. The Engineer engineer will make visits to the site and determine if the work is proceeding in accordance with the contract documents. 29.2 27.2 The Contractor contractor will be held strictly in to the intent of the contract documents in regards regard to the quality of materials, workmanship, workmanship and execution of the work. Inspections may be made at the factory or fabrication fabricated plant of the source of material supply. 29.3 27.3 The Engineer engineer will not be responsible for the construction means, controls, techniques, sequencesequences, procedures, or constuction construction safety. 29.4 27.4 The Engineer engineer shall promptly make decision decisions relative to interpretation of the contract documents.

Appears in 1 contract

Sources: Construction Contract

Engineer’s Authority. 29.1 27.1 The Engineer shall act as the Owner's representative during the construction period, . He shall decide questions which may arise as to quality and acceptability of materials furnished and work Work performed, and . He shall interpret the intent of the contract documents Contract Documents in a fair and unbiased manner. The Engineer will make visits to the site and determine if the work Work is proceeding in accordance with the contract documentsContract Documents. 29.2 27.2 The Contractor will be held strictly in to the intent of the contract documents in regards to Contract Documents regarding the quality of materials, workmanship, workmanship and execution of the workWork. Inspections may be made at the factory or fabrication plant of the source of material supply. 29.3 27.3 The Engineer will not be responsible for the construction means, controls, techniques, sequencesequences, procedures, or constuction construction safety. 29.4 27.4 The Engineer shall promptly make decision decisions relative to interpretation of the contract documentsContract Documents.

Appears in 1 contract

Sources: Agreement for Design, Installation, and Commissioning of Energy Conservation Facilities