Field Study. Based on requests from the County in determining the geotechnical needs of the project, the following number of borings and boring depths are proposed: Pedestrian Bridges 4 25 Retaining Wall 3 15 Boardwalk 3 15 Samples will be taken using conventional split‐spoon, Shelby‐tube, and NX rock core sampling techniques. Borings will be located in the field utilizing a recreation grade hand‐held GPS device and/or tape and right angle measurements from existing benchmarks. Our scope of service does not include surveying in the boring locations. Brush Clearing for equipment is included. The borings will be backfilled utilizing auger cuttings generated during drilling activities.