Gas Quality. 5.1. Gas delivered by Processing Customer to the Questar Receipt Point(s) shall: a. be commercially free from dust, gum, gum-forming constituents, liquid hydrocarbons, free water, diluent, and other liquids and solids; b. contain not more than 10 parts per million by volume of oxygen, and Processing Customer shall make every effort to keep Gas free from oxygen; c. contain not more than ¼ grain(s) of hydrogen sulfide per 100 Cubic Feet of Gas; d. contain not more than one grain(s) of total sulfur, including, but not limited to, sulfur in hydrogen sulfide and mercaptans, per 100 Cubic Feet of Gas; e. contain not more than 3% by volume total inerts, including but not limited to nitrogen and carbon dioxide; f. contains not more than 2% by volume carbon dioxide; g. have a temperature not greater than 120°F, nor less than 40°F; h. contain not more than 7 pounds per Mcf of water vapor; i. not contain measurable quantities of mercury; j. have a Gross Heating Value of not less than 1080 BTU per Cubic Foot; k. with the exception of Btu content and CHDP specifications, not exceed any of the specifications of the downstream pipelines at the Redelivery Points as they may exist from time to time. l. not contain other objectionable substances, including, but not limited to, polychlorinated biphenyls, which may be injurious to pipelines, people, property, or the environment which may interfere with its transportation or makes the Gas unmarketable or unacceptable at any Redelivery Point. 5.2. If Gas tendered by Processing Customer should fail to meet any one or more of the above specifications from time to time, then: a. Processor may accept delivery of the non-conforming Gas from Questar at the Plant Receipt Point, and such receipt shall not be construed as a waiver or change of standards for future Gas volumes; or b. Processor may, at its sole discretion, direct Questar to cease receiving the non-conforming Gas from Processing Customer, and notify Processing Customer that Questar has, or will, cease receiving the non-conforming Gas at the Questar Receipt Point. 5.3. If the Gas as delivered at the Questar Receipt Point contains contaminants not in conformance with the specifications in Section 5.1., Processing Customer shall be responsible for, and shall reimburse Processor for all actual expenses, damages and costs resulting from Delivery of such Gas by Questar at the Plant Receipt Point without regard to whether the Gas so delivered conforms with the specifications in Section 5.1.
Appears in 2 contracts
Sources: Gas Gathering and Processing Agreement (Gasco Energy Inc), Gas Processing Agreement (Gasco Energy Inc)
Gas Quality. 5.1. Gas delivered by Processing Customer Producer to the Questar Receipt Point(s) shall:
a. be commercially free from dust, gum, gum-forming constituents, liquid hydrocarbons, free water, diluent, and other liquids and solids;
b. contain not more than 10 parts per million by volume of oxygen, and Processing Customer Producer shall make every effort to keep Gas free from oxygen;
c. contain not more than ¼ 1/4 grain(s) of hydrogen sulfide per 100 Cubic Feet of Gas;
d. contain not more than one grain(s) of total sulfur, including, but not limited to, sulfur in hydrogen sulfide and mercaptans, per 100 Cubic Feet of Gas;
e. contain not more than 3% by volume total inerts, including but not limited to nitrogen and carbon dioxide;
f. contains not more than 2% by volume carbon dioxide;
g. have a temperature not greater than 120°F, nor less than 40°F40oF;
h. contain not more than 7 pounds per Mcf of water vapor;
i. not contain measurable quantities of mercury;
j. i. have a Gross Heating Value of not less than 1080 1060 BTU per Cubic Foot;
k. with the exception of Btu content and CHDP specifications, j. not exceed any of the specifications of the downstream pipelines at the Redelivery Points as they may exist from time to time.
l. k. not contain other objectionable substances, including, but not limited to, polychlorinated biphenyls, which may be injurious to pipelines, people, property, or the environment which may interfere with its transportation or makes the Gas unmarketable or unacceptable at any Redelivery Point.
l. Notwithstanding the above, unless otherwise agreed by Processor in writing, Processor shall not be required to receive Gas at any Receipt Point which is of quality inferior to that required by a Producer or a third party at any Redelivery Point. Processor shall not be liable to any party for any damages, direct, indirect, consequential or otherwise, incurred as a result of Processor’s refusal to receive Gas as a result of this provision.
5.2. If Gas tendered by Processing Customer Producer should fail to meet any one or more of the above specifications from time to time, then:
a. Processor may accept delivery take receipt of the non-conforming Gas from Questar at the Plant Receipt PointGas, and such that receipt shall not be construed as a waiver or change of standards for future Gas volumes; or
b. Processor may, at its sole discretion, direct Questar to cease receiving the non-conforming Gas from Processing CustomerProducer, and shall notify Processing Customer Producer that Questar it has, or will, cease receiving the non-conforming Gas at the Questar Receipt Point.Gas; or
5.3. If c. if the Gas as delivered at the Questar Receipt Point contains contaminants not in conformance with the specifications in Section 5.1., Processing Customer then Producer shall be responsible for, and shall reimburse Processor for all actual expenses, damages and costs resulting from Delivery of such Gas by Questar at the Plant Receipt Point without regard to whether the Gas so delivered conforms with the specifications in Section 5.1therefrom.
Appears in 1 contract
Sources: Limited Liability Company Agreement (Western Gas Partners LP)
Gas Quality. 5.1. Gas delivered by Processing Customer Producer to the Questar Receipt Point(s) shall:
a. be commercially free from dust, gum, gum-forming constituents, liquid hydrocarbons, free water, diluent, and other liquids and solids;
b. contain not more than 10 parts per million by volume of oxygen, and Processing Customer Producer shall make every effort to keep Gas free from oxygen;
c. contain not more than ¼ 1/4 grain(s) of hydrogen sulfide per 100 Cubic Feet of Gas;
d. contain not more than one grain(s) of total sulfur, including, but not limited to, sulfur in hydrogen sulfide and mercaptans, per 100 Cubic Feet of Gas;
e. contain not more than 3% by volume total inerts, including but not limited to nitrogen and carbon dioxide;
f. contains not more than 2% by volume carbon dioxide;
g. Shall not contain water vapor in excess of 5 pounds per million cubic feet of Gas;
h. have a temperature not greater than 120°F, nor less than 40°F;
h. contain not more than 7 pounds per Mcf of water vapor40oF;
i. not contain measurable quantities of mercury;
j. have a Gross Heating Value of not less than 1080 1060 BTU per Cubic Foot;
k. with the exception of Btu content and CHDP specificationsExcept for hydrocarbon content, shall not exceed any of the specifications of the downstream pipelines at the Redelivery Points as they may exist from time to time.
l. not contain other objectionable substances, including, but not limited to, polychlorinated biphenyls, which may be injurious injuries to pipelines, people, property, or the environment which may interfere with its transportation or makes the Gas unmarketable or unacceptable at any Redelivery Point.
m. Notwithstanding the above, unless otherwise agreed by Processor in writing, Processor shall not be required to receive Gas at any Receipt Point which is of quality inferior to that required by a Producer or a third party at any Redelivery Point. Processor shall not be liable to any party for any damages, direct, indirect, consequential or otherwise, incurred as a result of Processor’s refusal to receive Gas as a result of this provision.
5.2. If Gas tendered by Processing Customer Producer should fail to meet any one or more of the above specifications from time to time, then:
a. Processor may accept delivery take receipt of the non-conforming Gas from Questar at the Plant Receipt PointGas, and such that receipt shall not be construed as a waiver or change of standards for future Gas volumes; or
b. Processor may, at its sole discretion, direct Questar to cease receiving the non-conforming Gas from Processing CustomerProducer, and shall notify Processing Customer Producer that Questar it has, or will, cease receiving the non-conforming Gas at the Questar Receipt Point.Gas; or
5.3. If c. if the Gas as delivered at the Questar Receipt Point contains contaminants not in conformance with the specifications in Section 5.1., Processing Customer then Producer shall be responsible for, and shall reimburse Processor for all actual expenses, damages and costs resulting from Delivery of such Gas by Questar at the Plant Receipt Point without regard to whether the Gas so delivered conforms with the specifications in Section 5.1therefrom.
Appears in 1 contract
Sources: Limited Liability Company Agreement (Western Gas Partners LP)