Heating Value of Gas. (a) Delivered Gas shall have a Gross Heating Value of not less than nine hundred fifty (950) Btu’s per cubic foot nor more than one thousand fifty (1,050) Btu’s per cubic foot. (b) The Gross Heating Value of Gas shall be determined from a representative composite Gas sample taken at the point of measurement by periodic tests to be conducted monthly by Buyer or at such other intervals as the parties may mutually agree. The determination may be made by means of a calorimeter using the ▇▇▇▇▇▇ principle of calorimetry or its equal or by calculation from the component analysis using NGPA Publication 2145, as it may be revised, entitled “Physical Constants of Paraffin Hydrocarbons or Other Compounds of Natural Gas”.