Common use of Isolation Clause in Contracts

Isolation. All new equipment furnished shall be mounted on vibration- absorption mounts, designed to effectively prevent vibrations to structure, and thereby eliminate sources of structure-borne noise from elevator system. FIELD QUALITY CONTROL Acceptance-Testing - Upon nominal completion of elevator modifications, and before permitting use of elevator (either temporary or permanent), perform acceptance tests as required and recommended by Code, and also perform other tests, if any, as required by governing authorities. Advise the Owners consultant or agent in advance of dates and times tests are to be performed on elevators. The tests will not have to be duplicated or witnessed by the Consultant if the AHJ witnessed the test and a copy of the test is forwarded to the Consultant.

Appears in 2 contracts

Sources: Project Agreement, Project Agreement

Isolation. All new equipment furnished shall be mounted on vibration- vibration-absorption mounts, designed to effectively prevent vibrations to structure, and thereby eliminate sources of structure-structure- borne noise from elevator system. FIELD QUALITY CONTROL Acceptance-Testing - Upon nominal completion of elevator modifications, and before permitting use of elevator (either temporary or permanent), perform acceptance tests as required and recommended by Code, and also perform other tests, if any, as required by governing authorities. Advise the Owners consultant or agent in advance of dates and times tests are to be performed on elevators. The tests will not have to be duplicated or witnessed by the Consultant if the AHJ witnessed the test and a copy of the test is forwarded to the Consultant.

Appears in 1 contract

Sources: Project Agreement