Common use of Laboratory Waste Clause in Contracts

Laboratory Waste. Risers and drains as shown in the CAD files provided by Sublandlord to Subtenant. • 4,000 amp, 480/277 volt Main Switch Board located on the G-1 level below each building • Normal power distribution rooms are located on each floor with 100 amp 480/277 volt lighting panels and 45KVA transformers along with 150 amp 120/208 volt convenience power panels. • Emergency power distribution rooms are located on each floor with 100 amp 480/277 volt lighting panels and 45KVA transformers along with 150 amp 120/208 volt convenience power panels • Life Safety Power are located on each floor with 50 amp 480/277 volt lighting panels and 50 amp 120/208 volt panels • Motor Control Center for roof top equipment are located on the roof • Power metering is provided on each floor to measure power consumption floor by floor. • The Premises is provided with a 1,000 KW Generator with two, bypass isolation type, transfer switches. One for life safety functions while the other serves tenant loads. SMRH:473310031.19 C-2 ▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇▇▇▇▇. SUBLEASE - PROTHENA BIOSCIENCES FINAL EXECUTION VERSION 0SDM-159614 SV\1619361.8 SV\1619361.8 • A new fire alarm system, with code compliant smoke control in each building, a control panel located on the ground floor within the new fire control room.

Appears in 1 contract

Sources: Sublease (Prothena Corp PLC)

Laboratory Waste. Risers and drains as shown in the CAD files provided by Sublandlord to Subtenant. 4,000 amp, 480/277 volt Main Switch Board located on the G-1 G-l level below each building Normal power distribution rooms are located on each floor with 100 amp 480/277 volt lighting panels and 45KVA transformers along with 150 amp 120/208 volt convenience power panels. Emergency power distribution rooms are located on each floor with 100 amp 480/277 volt lighting panels and 45KVA transformers along with 150 amp 120/208 volt convenience power panels Life Safety Power are located on each floor with 50 amp 480/277 volt lighting panels and 50 amp 120/208 volt panels Motor Control Center for roof top equipment are located on the roof Power metering is provided on each floor to measure power consumption floor by floor. The Premises is provided with a 1,000 KW Generator with two, bypass isolation type, transfer switches. One for life safety functions while the other serves tenant loads. SMRH:473310031.19 SMRH: 473310031.19 C-2 3▇▇ ▇▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇▇▇▇▇. SUBLEASE - BOULEVARD.SUBLEASE – PROTHENA BIOSCIENCES FINAL EXECUTION VERSION 0SDM-159614 SV\1619361.8 SV\1619361.8 • A new fire alarm system, with code compliant smoke control in each building, a control panel located on the ground floor within the new fire control room.

Appears in 1 contract

Sources: Sub Sublease (Assembly Biosciences, Inc.)