Light sources Sample Clauses

Light sources. 4.3.1. In the case of replaceable light source(s): 4.3.1.1. The lamp shall only be equipped with light source(s) approved according to UN Regulation No. 37 and/or UN Regulation No. 128, provided that no restriction on the use is made in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 128 and its series of amendments in force at the time of application for type approval. 4.3.1.2. In the case of a light source category or categories or type(s) is restricted for use in lamps on vehicles in use and originally equipped with such lamps, the applicant for type approval of the lamp shall declare that the lamp is only intended for installation on those vehicles; this shall be noted in the communication form in Annex 1. 4.3.1.3. The design of the lamp shall be such that the light source(s) can be fixed in no other position but the correct one. 4.3.1.4. The light source(s) holder shall conform to the characteristics given in IEC Publication 60061. The holder data sheet relevant to the category of light source(s) used, applies. 4.3.2. In the case of light source modules, it shall be checked that: 4.3.2.1. The design of the light source module(s) shall be such as: (a) That each light source module can only be fitted in no other position than the designated and correct one and can only be removed with the use of tool(s); (b) If there are more than one light source module used in the housing for a lamp, light source modules having different characteristics cannot be interchanged within the same lamp housing. 4.3.2.2. The light source module(s) shall be tamperproof. 4.3.2.3. A light source module shall be so designed that regardless of the use of tool(s), it shall not be mechanically interchangeable with any replaceable approved light source. 4.3.2.4. In the case of non-replaceable filament light source(s) or light source module(s) equipped with non-replaceable filament light source(s), the applicant shall annex to the type approval documentation a report, acceptable to the Authority responsible for type approval, that demonstrates compliance of these non-replaceable filament light source(s) with the requirements as specified in paragraph 4.11 of IEC 60809, Edition 3.
Light sources. 5.8.1. The gas-discharge light source(s) used in gas-discharge headlamps shall be replaceable and approved according to Regulation No. 99 and its series of amendments in force at the time of application for type approval. 5.8.2. In the case that one or more (additional) filament light sources are used in the gas-discharge headlamp, these filament light sources shall be replaceable and approved according to Regulation No. 37 and its series of amendments in force at the time of application for type approval, provided that no restriction on the use is made in Regulation No. 37 and its series of amendments in force at the time of application for type approval. 5.8.3. In the case that one or more (additional) LED light sources are used in the gas-discharge headlamp, these LED light sources shall be approved according to Regulation No. 128 and its series of amendments in force at the time of application for type approval, provided that no restriction on the use is made in Regulation No. 128 and its series of amendments in force at the time of application for type approval. 5.8.4. In case that one or more (additional) LED modules are used in the gas- discharge headlamp, these LED modules shall be replaceable or non- replaceable.
Light sources. The transfer price from PDTI to P&U shall be ***** of PDTI's list price.
Light sources. Source of visible light using a self-regulating power supply capable of operating at 110 volts/60 Hz or 220 volts/50 Hz. - Portable (not to exceed 10 kg). - Noise level [less than] TBD dB at TBD meters on all sides. - Provides visible light (470-520 nm wavelength range) at 400 milliwatts minimum output bandwidth at factory set duration of 40 seconds. - Maximum delay of 0.1 seconds between pulses. - Surgeon control allows mid-cycle light shut-off. - Customer Replaceable, self-aligning lamp. - Target Cost of Goods with overhead: [less than or equal to]$3,258 each (assuming > 300 units/year). - Optical/electrical connector is easy to inert and remove, but difficult to inadvertently remove. - The light source is packaged non-sterile. - Passes EN60601 ISO standard for earth ground and leakage current.
Light sources. 4.5.1 In the case of replaceable light sources: 4.5.1.1. The lamp shall only be equipped with light source(s) approved according to UN Regulations Nos. 37, 99 and/or 128, provided that no restriction on the use is made in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 99 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 128 and its series of amendments in force at the time of application for type approval. … 4.5.1.2. In case a light source category or categories or type(s) is restricted for use in lamps on vehicles in use and originally equipped with such lamps, the applicant for type approval of the lamp shall declare that the lamp is only intended for installation on those vehicles; this shall be noted in the communication form 4.5.1.3. The design of the lamp shall be such that the light source(s) can be fixed in no other position but the correct one.
Light sources. 4.3.1 In the case of replaceable light source(s): 4.3.1.1 Any category or categories of light source(s) approved according to UN Regulation No. 37 and/or UN Regulation No. 128 may be used, provided that no restriction on the use is made in UN Regulation No. 37 and its series of amendments in force at the time of application for type approval or in UN Regulation No. 128 and its series of amendments in force at the time of application for type approval.
Light sources. The CV8000 is a fully automated imaging platform for confocal, bright field, epifluorescent and phase contract imaging. Standard excitation lasers are 405, 488, 561 and 640 nm. A laser for FRET (445nm) excitation is also included. Bright field and phase contrast imaging use the LED white light source. There is also a Fully incubated stage with humidity control (maximum 85% rH), temperature control (from ambient +5°C - 40°C) and CO2 control. Enables live cell imaging for up to 72 hours (3 days). The CV8000 provides both laser-based autofocus and image-based autofocus. Capable of imaging 6, 12, 24, 48, 96, 384 and 1536-well microplates, as well as microscope slides with a slide holder (included).
Light sources 

Related to Light sources

  • Other Sources Indemnitee shall not be required to exercise any rights that Indemnitee may have against any other Person (for example, under an insurance policy) before Indemnitee enforces his rights under this Agreement. However, to the extent the Company actually indemnifies Indemnitee or advances him Expenses, the Company shall be subrogated to the rights of Indemnitee and shall be entitled to enforce any such rights which Indemnitee may have against third parties. Indemnitee shall assist the Company in enforcing those rights if it pays his costs and expenses of doing so. If Indemnitee is actually indemnified or advanced Expenses by any third party, then, for so long as Indemnitee is not required to disgorge the amounts so received, to that extent the Company shall be relieved of its obligation to indemnify Indemnitee or advance Indemnitee Expenses.

  • Information Sources The Custodian may rely upon information received from issuers of Investments or agents of such issuers, information received from Subcustodians and from other commercially reasonable sources such as commercial data bases and the like, but shall not be responsible for specific inaccuracies in such information, provided that the Custodian has relied upon such information in good faith, or for the failure of any commercially reasonable information provider.

  • Fuel The Vehicle must be returned with the amount of fuel equal to that at the time of the commencement of the rental. If the Vehicle is returned with less fuel, the difference will be charged to You at a rate of $5.00 per litre (which includes a service component).

  • SINGLE-USE PRODUCTS The Board of County Commissioners has established a single-use products and plastic bags policy intended to reduce the use of products which have become globally recognized as having lasting negative impacts on the environment. Neither single-use products nor plastic bags may be sold or disbursed on County property by staff or contracted vendors, except as set forth in Orange County Administrative Regulation 9.01.03. Failure to comply with the Regulation may result in termination of the contract or other contractual remedies, and may affect future contracting with the County. The use of reusable, recyclable, biodegradable, or compostable materials is encouraged.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Freedom has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Freedom. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Freedom (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Freedom, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Freedom will then have the option of paying the one-time SC rates to place the Loop.