Lot Design and Building Siting Requirements. 3.5.1 Where 50’ Single Unit Dwellings are permitted, as shown on Schedule B, the following provisions shall apply: (a) Minimum Lot Frontage 15.24 metres (50 feet) (b) Minimum Lot Area 464.52 sq. metres (5,000 sq. feet) (c) Minimum Front or Flankage Yard 6.1 metres (20 feet) (d) Minimum Side or Rear Yard 2.44 metres (8 feet) (e) Maximum Lot Coverage 35 percent (f) Maximum Building Height 10.67 metres (35 feet) 3.5.2 Where 60’ Single Unit Dwellings are permitted, as shown on Schedule B, the following provisions shall apply: (a) Minimum Lot Frontage 18.29 metres (60 feet) (b) Minimum Lot Area 557.42 sq. metres (6,000 sq. feet) (c) Minimum Front or Flankage Yard 6.1 metres (20 feet) (d) Minimum Side or Rear Yard 2.44 metres (8 feet) (e) Maximum Lot Coverage 35 percent (f) Maximum Building Height 10.67 metres (35 feet) 3.5.3 Where 70’ Semi-detached Dwellings are permitted, as shown on Schedule B, the following provisions shall apply: (a) Minimum Lot Frontage 21.34 metres (70 feet) (b) Minimum Lot Area 650.32 sq. metres (7,000 sq. feet) (c) Minimum Front or Flankage Yard 6.1 metres (20 feet) (d) Minimum Side or Rear Yard 2.44 metres (8 feet) or 0 metres from the common wall (e) Maximum Lot Coverage 35 percent (f) Maximum Building Height 10.67 metres (35 feet) 3.5.4 Notwithstanding Sections 3.5.1 and 3.5.2, where 50’ Single Unit Dwellings and 60’ Single Unit Dwellings are permitted, as shown on Schedule B, the minimum side yard of one side yard may be reduced to 1.22 metres (4 feet) provided that a separation distance of 3.66 metres (12 feet) is maintained between each dwelling unit.