Magnetometer. Figure of Merit (FOM) A test will be flown on-site prior to the survey to determine the FOM of the installed magnetometer. The system will be flown on the four cardinal headings doing a pitch (5 degrees), roll (10 degrees), and yaw (5 degrees), maneuver on each. The FOM will be calculated by summing the absolute errors of each of the 12 maneuvers and will be less than 1.5nT. Lag test The magnetometer lag with respect to the GPS system will be determined prior to the survey by passes in opposite directions at standard speed and height over a clearly identifiable strongly magnetic object.