Common use of Measurement Devices Clause in Contracts

Measurement Devices. (a) All Crude Oil and NGLs Tendered hereunder at Receipt Points and Delivery Points shall be measured by a suitable Measurement Device to be furnished and installed (or caused to be furnished and installed) by Provider, and subsequently kept in repair (or caused to be kept in repair) by Provider, and located at or near such Receipt Points and Delivery Points. Such Measurement Devices shall be installed, and operated in accordance with the American Petroleum Institute Manual of Petroleum Measurement Standards (the “MPMS”) Chapter 5.2 Measurement of Liquid Hydrocarbons by Displacement Meters October 2005, Reaffirmed September 2010, and/or Chapter 5.6 Measurement of liquid Hydrocarbons by Coriolis Meters October 2002, Reaffirmed March 2008, and/or Chapter 5.3 Measurement of Liquid Hydrocarbons by Turbine Meters September 2005 (including Addendum 1 dated 2009) and all amendments and supplements thereto prior to the date of such installation. (b) For Crude Oil in determining the amount of sediment, water, or other impurities and the API Gravity for each Unit Train, the Terminals System shall utilize a proportion to flow composite sampler. For NGLs in determining the component analysis when required, the Terminals System shall utilize a proportion to flow composite sampler. The sampling device shall be installed, and operated in accordance with the MPMS Chapter 8.2 Standard Practice of Automatic Sampling of Liquid Petroleum and Petroleum products Second Edition, October 1995, Reaffirmed, March 2010. All samples shall be mixed and handled in accordance with the MPMS Chapter 8.3 Standard Practice for Mixing and Handling of Liquid Samples of Petroleum and Petroleum Products First Edition, October 1995, Reaffirmed March 2010.

Appears in 2 contracts

Sources: Terminal and Export Services Agreement (Hess Midstream Partners LP), Terminal and Export Services Agreement (Hess Midstream Partners LP)

Measurement Devices. (a) All Crude Oil and NGLs Tendered hereunder at Receipt Points and Delivery Points shall be measured by a suitable Measurement Device measurement device to be furnished and installed (or caused to be furnished and installed) by ProviderGatherer, and subsequently kept in repair (or caused to be kept in repair) by ProviderGatherer, and located at or near such Receipt Points and Delivery Points. Such Measurement Devices measurement devices shall be installed, and operated in accordance with the American Petroleum Institute Manual of Petroleum Measurement Standards (the “MPMS”) Chapter 5.2 Measurement of Liquid Hydrocarbons by Displacement Meters October 2005, Reaffirmed September 2010, and/or Chapter 5.6 Measurement of liquid Hydrocarbons by Coriolis Meters October 2002, Reaffirmed March 2008, and/or Chapter 5.3 Measurement of Liquid Hydrocarbons by Turbine Meters September 2005 (including Addendum 1 dated 2009) and all amendments and supplements thereto prior to the date of such installation. (b) For Crude Oil in determining the amount of sediment, water, or other impurities and the API Gravity for each Unit TrainGravity, the Terminals System shall utilize a proportion to flow composite sampler. For NGLs in determining the component analysis when required, the Terminals Gathering System shall utilize a proportion to flow composite sampler. The sampling device shall be installed, and operated in accordance with the MPMS Chapter 8.2 Standard Practice of Automatic Sampling of Liquid Petroleum and Petroleum products Second Edition, October 1995, Reaffirmed, March 2010. All samples shall be mixed and handled in accordance with the MPMS Chapter 8.3 Standard Practice for Mixing and Handling of Liquid Samples of Petroleum and Petroleum Products First Edition, October 1995, Reaffirmed March 2010.

Appears in 2 contracts

Sources: Crude Oil Gathering Agreement (Hess Midstream Partners LP), Crude Oil Gathering Agreement (Hess Midstream Partners LP)

Measurement Devices. (a) All Crude Oil and NGLs Tendered hereunder at Receipt Points and Delivery Points shall be measured by a suitable Measurement Device measurement device to be furnished and installed (or caused to be furnished and installed) by ProviderGatherer, and subsequently kept in repair (or caused to be kept in repair) by ProviderGatherer, and located at or near such Receipt Points and Delivery Points. Such Measurement Devices measurement devices shall be installed, and operated in accordance with the American Petroleum Institute Manual of Petroleum Measurement Standards (the "MPMS") Chapter 5.2 Measurement of Liquid Hydrocarbons by Displacement Meters October 2005, Reaffirmed September 2010, and/or Chapter 5.6 Measurement of liquid Hydrocarbons by Coriolis Meters October 2002, Reaffirmed March 2008, and/or Chapter 5.3 Measurement of Liquid Hydrocarbons by Turbine Meters September 2005 (including Addendum 1 dated 2009) and all amendments and supplements thereto prior to the date of such installation. (b) For Crude Oil in determining the amount of sediment, water, or other impurities and the API Gravity for each Unit TrainGravity, the Terminals System shall utilize a proportion to flow composite sampler. For NGLs in determining the component analysis when required, the Terminals Gathering System shall utilize a proportion to flow composite sampler. The sampling device shall be installed, and operated in accordance with the MPMS Chapter 8.2 Standard Practice of Automatic Sampling of Liquid Petroleum and Petroleum products Second Edition, October 1995, Reaffirmed, March 2010. All samples shall be mixed and handled in accordance with the MPMS Chapter 8.3 Standard Practice for Mixing and Handling of Liquid Samples of Petroleum and Petroleum Products First Edition, October 1995, Reaffirmed March 2010.

Appears in 1 contract