NOT ACCEPTABLE Clause Samples

NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (ARPL01) Analytical Support Operations - Radiochemical Processing Lab PO Box 999 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.208 0.528 A -60.6 0.158 - 0.898 0.010 A Gross beta 0.866 0.915 A -5.4 0.458 - 1.373 0.031 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP < 2% ACCEPTABLE. 2% <= RP <= 15% ACCEPTABLE WITH WARNING. 15% < RP <= 30% NOT ACCEPTABLE. RP > 30% Relative Precision (RP) = (Reported Uncertainty / Reported Result) x 100 (ARPL01) Analytical Support Operations - Radiochemical Processing Lab PO Box 999 Radiological Units: (Bq/L) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.231 0.232 A -0.4 0.070 - 0.394 0.040 W Gross beta 2.73 2.807 A -2.7 1.404 - 4.211 0.11 A A = Result acceptable, Bias <= ± 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > ± 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP < 2% ACCEPTABLE. 2% <= RP <= 15% ACCEPTABLE WITH WARNING. 15% < RP <= 30% NOT ACCEPTABLE. RP > 30% Relative Precision (RP) = (Reported Uncertainty / Reported Result) x 100 (CMRC01) Carlsbad Environmental Monitoring and Research Center ▇▇▇▇ ▇▇▇▇▇▇▇▇▇▇ ▇▇. Carlsbad, NM 88220 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.665 1.20 A -44.6 0.36 - 2.04 0.015 A Gross beta 0.778 0.681 A 14.2 0.341 - 1.022 0.010 N
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (NESI01) BWXT-Radioisotope & Analytical Chemistry Laboratory Lynchburg Technology Center Lynchburg, VA 24504-5447 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.419 0.528 A -20.6 0.158 - 0.898 0.016 A Gross beta 0.925 0.948 A -2.4 0.474 - 1.422 0.012 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (HECR01) SC Dept. Health and Environmental Control Radiological Laboratory ▇▇▇▇ ▇▇▇▇▇▇▇▇ ▇▇▇▇ Columbia, SC 29223 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.209 0.528 A -60.4 0.158 - 0.898 0.0373 W Gross beta 0.945 0.915 A 3.3 0.458 - 1.373 0.0574 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision ‌ The intent of the distribution graphs contained within this report is to graphically demonstrate to users how % Bias data within the current MAPEP Series appears when examined by matrix, by analyte, by method of sample preparation or by method of detection. Biases greater than +/- 100% have been screened from the data. The box plot of the bias data points and the mean visually illustrate the breadth of the distribution and where potential outliers in the distribution might lie. The statistics for the distribution plot are provided adjacent to the Bias plot. In some cases, N becomes very small and thus developed statistics may not accurately reflect estimates of the population if N were a significantly larger value.
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (NESI01) BWXT-Radioisotope & Analytical Chemistry Laboratory Lynchburg Technology Center Lynchburg, VA 24504-5447 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 1.11 1.24 A -10.5 0.37 - 2.11 0.058 A Gross beta 1.83 2.00 A -8.5 1.00 - 3.00 0.040 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP < 2% ACCEPTABLE. 2% <= RP <= 15% ACCEPTABLE WITH WARNING. 15% < RP <= 30% NOT ACCEPTABLE. RP > 30% Relative Precision (RP) = (Reported Uncertainty / Reported Result) x 100 (TNUT01) St. ▇▇▇▇▇ USACE FUSRAP Laboratory ▇▇▇ ▇▇▇▇▇ ▇ ▇▇▇▇▇▇▇▇▇ Blvd HAZELWOOD, MO 63042 Radiological Units: (Bq/L) Analyte Ref Result Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.07217 0.574 N -87.4 0.172 - 0.976 0.1448 N Gross beta 7.3006 7.25 A 0.7 3.63 - 10.88 0.2201 A
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (TNUT01) St. ▇▇▇▇▇ USACE FUSRAP Laboratory ▇▇▇▇ ▇▇▇▇▇ ▇▇▇ BERKELEY, MO 63134-1024 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha .5386 0.528 A 2.0 0.158 - 0.898 0.0215 A Gross beta .9543 0.937 A 1.8 0.469 - 1.406 0.0381 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
NOT ACCEPTABLE. RP < 2% ACCEPTABLE. 2% <= RP <= 15% ACCEPTABLE WITH WARNING. 15% < RP <= 30% NOT ACCEPTABLE. RP > 30% Relative Precision (RP) = (Reported Uncertainty / Reported Result) x 100 (NJDH01) New Jersey Dept. of Health, PHEL, ECLS ▇ ▇▇▇▇▇▇▇▇▇▇▇ ▇▇▇▇▇ West Trenton, NJ 08628 Radiological Units: (Bq/L) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.328 0.232 A 41.4 0.070 - 0.394 0.027 A Gross beta 2.808 2.807 A 0.0 1.404 - 4.211 0.070 A A = Result acceptable, Bias <= ± 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > ± 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).