Operating Temperature. 8 The BBS and all components must operate without performance degradation over a 9 temperature range of -40°C to +74°C with a maximum load of 70 percent of rated output of the 10 BBS inverter.
Operating Temperature. 18 The battery system must consist of one or more strings of extreme temperature; float cycle GEL 19 valve regulated lead acid batteries. Batteries must be certified to operate at extreme 20 temperatures from –40°C to +71°C.
Operating Temperature. The Operating Temperature range for the completed product "home safety light" to be between 0 degrees Celsius and 45 degrees Celsius.
Operating Temperature. 40°F to +165°F (Derating after +131°F)
Operating Temperature. The gas operating temperature is expected to be no higher than 60 degrees Farenheit. The temperature derating factor (T) will be 1.00. (See 49 C.F.R. § 192.115.)
Operating Temperature. Can withstand temperatures of -20c to +50c (-4F to +122F) Average Thickness: 0.6mm and minimum corner thickness of 0.5mm Fitted with: The container must incorporate a built-in carrying handle which must be a minimum of 9cm long and 3cm high, with no sharp edges. The handle is the principle means of carrying the container. The container must also incorporate a screwable cap for filling and discharge that is linked to the container by a polyamide retaining strap with diameter of min 1mm and approximately 120mm length. The inner diameter of the cap must be approximately 35mm, with the opening in the container of a corresponding size. Impact Resistance / Drop Test: The water container will be impact resistant on a hard surface when filled with the maximum volume of water (10-Liters) at 20oC. The complete drop test consists of 10 consecutive drops from 2.5m high. The water container must be elevated, so that the lowest point is at 2.5m from the ground. Test result is expressed as a product ranking according to the number of drops passed without damages or leakage. To be accepted, the water container must resist to minimum 3 drops. This section is Not Applicable unless the Contracting Officer amends the contract bilaterally otherwise.
Operating Temperature. The transceiver shall be capable of continuous operation over an ambient temperature range of ___ degrees C to ___ degrees C in still air. The tests for low temperature and high temperature are defined in MIL-STD-810E Procedure II, Methods 502.3 and 501.3 respectively.

Related to Operating Temperature

  • Temperature Where low temperature and/or self-service cases are used for any of such merchandise coming under the jurisdiction of the Union, such cases shall be served only by employees covered by this Agreement.

  • Meters 7.1.1 For installation of Meters, Meter testing, Meter calibration and Meter reading and all matters incidental thereto, the SPD and SECI shall follow and be bound by the Central Electricity Authority (Installation and Operation of Meters) Regulations, 2006, the Grid Code, as amended and revised from time to time. 7.1.2 The SPD shall bear all costs pertaining to installation, testing, calibration, maintenance, renewal and repair of meters at SPD’s side of Delivery Point. 7.1.3 In addition to ensuring compliance of the applicable codes, the SPD shall install Main & Check meters at the Delivery Point, along with Stand-by meter(s) as per the applicable Central/State regulations. 7.1.4 In case of pooling of multiple Projects, power from multiple Projects can be pooled at a Pooling Substation prior to the Delivery point and the combined power can be fed at Delivery point through a common transmission line from the Pooling Substation. In such cases, ABT compliant sub-meters as per relevant regulation/approval are also to be set up at pooling substation for individual projects in addition to the meters at Delivery Point as described in clause 7.1.3.

  • Rent Rolls; Operating Histories The Seller has obtained a rent roll (the “Certified Rent Roll(s)”) other than with respect to hospitality properties certified by the related Mortgagor or the related guarantor(s) as accurate and complete in all material respects as of a date within 180 days of the date of origination of the related Mortgage Loan. The Seller has obtained operating histories (the “Certified Operating Histories”) with respect to each Mortgaged Property certified by the related Mortgagor or the related guarantor(s) as accurate and complete in all material respects as of a date within 180 days of the date of origination of the related Mortgage Loan. The Certified Operating Histories collectively report on operations for a period equal to (a) at least a continuous three-year period or (b) in the event the Mortgaged Property was owned, operated or constructed by the Mortgagor or an affiliate for less than three years then for such shorter period of time, it being understood that for mortgaged properties acquired with the proceeds of a Mortgage Loan, Certified Operating Histories may not have been available.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Developer Operating Requirements The Developer must comply with the Transmission Owner’s operating instructions and requirements including but not limited to Transmission Owner’s Operation Coordination Agreement, as it may change from time to time. The Developer must comply with all applicable NYISO tariffs and procedures, as amended from time to time. Whether or not the Large Generating Facility is eligible for the Transition Period LVRT Standard set forth in Appendix G will be determined by the Commission. The Large Generating Facility will comply with the Transition Period LVRT Standard pending issuance of an order by the Commission determining the appropriate LVRT standard. For purposes of compliance with Appendix G, the Transmission Owner has determined that the Developer shall maintain the Large Generating Facility in service during a three-phase fault for 7 cycles. Infrastructure security of New York State Transmission System equipment and operations and control hardware and software is essential to ensure day-to-day New York State Transmission System reliability and operational security. The Commission will expect the NYISO, all Transmission Owners, all Developers and all other Market Participants to comply with the recommendations offered by the President’s Critical Infrastructure Protection Board and, eventually, best practice recommendations from the electric reliability authority. All public utilities will be expected to meet basic standards for system infrastructure and operational security, including physical, operational, and cyber-security practices. All personnel working in Transmission Owner’s facilities will require security background checks prior to entering and working in such facilities. New York Independent System Operator, Inc. Attn: Vice President, Operations ▇▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇ Schenectady, NY 12303 Senior Vice President of Transmission New York Power Authority ▇▇▇ ▇▇▇▇ ▇▇. ▇▇▇▇▇ ▇▇▇▇▇▇, ▇▇ ▇▇▇▇▇-▇▇▇▇ Re: Large Generating Facility Dear : On [Date] [Developer] has completed Trial Operation of Unit No. . This letter confirms that [Developer] commenced Commercial Operation of Unit No. at the Large Generating Facility, effective as of [Date plus one day]. Thank you. NYISO: