Operational Support Systems (OSS The terms, conditions and rates for OSS are as set forth in Section 2.13 of this Attachment.
Transitional Services Upon cancellation, termination, or expiration of the Contract for any reason, the Contractor shall provide reasonable cooperation, assistance and Services, and shall assist the Department to facilitate the orderly transition of the work under the Contract to the Department and/or to an alternative contractor selected for the transition upon written notice to the Contractor at least thirty (30) business days prior to termination or cancellation, and subject to the terms and conditions set forth in the Contract.
Transactional Services The Service Provider shall communicate to its Customers, as to shares of the Fund, purchase, redemption and exchange orders reflecting the orders it receives from its Customers or from any brokers and banks for their Customers. The Service Provider shall also communicate to beneficial owners holding through it, and to any brokers or banks for beneficial owners holding through them, as to shares of the Fund, mergers, splits and other reorganization activities, and require any broker or bank to communicate such information to its Customers.
Operational Support Systems 14.1 BellSouth has developed and made available electronic interfaces by which Unity Acquisition may submit LSRs electronically. 14.2 LSRs submitted by means of one of these electronic interfaces will incur an OSS electronic ordering charge. An individual LSR will be identified for billing purposes by its Purchase Order Number (PON). LSRs submitted by means other than one of these interactive interfaces (mail, fax, courier, etc.) will incur a manual order charge. All OSS charges are specified in Exhibit A of this Attachment.
Synchronization, Commissioning and Commercial Operation 5.1.1 The SPG shall give PGVCL at least thirty (30) days’ advanced preliminary written notice and at least fifteen (15) days’ advanced final written notice, of the date on which it intends to synchronize the Solar Power Project to the Grid System. 5.1.2 Subject to Article 5.1.1, the Power Project may be synchronized by the SPG to the Grid System when it meets all the connection conditions prescribed in applicable Grid Code then in effect and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 5.1.3 The synchronization equipment and all necessary arrangements / equipment including RTU for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the SPG at its generation facility of the Power Project at its own cost. The SPG shall synchronize its system with the Grid System only after the approval of synchronization scheme is granted by the head of the concerned substation/ and checking/verification is made by the concerned authorities of the PGVCL. 5.1.4 The SPG shall immediately after each synchronization/tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. In addition, the SPG will inject in-firm power to grid from time to time to carry out operational/ functional test prior to commercial operation. For avoidance of doubt, it is clarified that Synchronization / Connectivity of the Project with the grid shall not to be considered as Commissioning of the Project. 5.1.5 The SPG shall commission the Project within nine (9) Months from the Date of execution of this PPA. Declaration of COD shall be certified by the commissioning committee. 5.1.6 The Parties agree that for the purpose of commencement of the supply of electricity by SPG to PGVCL, liquidated damages for delay etc., the Scheduled Commissioning Date as defined in this Agreement shall be the relevant date.