Common use of Other System Upgrade Facilities Clause in Contracts

Other System Upgrade Facilities. The Developer shall perform its responsibilities described in this Section 2(b) of Appendix A in accordance with the Connecting Transmission Owner’s requirements, as described above in Section 1(a) of this Appendix A, and the other provisions of this Agreement applicable to System Upgrade Facilities to be engineered, designed, procured, constructed and installed by Developer, including Article 5.2. i. Transmission Line Facilities The Developer shall be responsible for designing, engineering, procuring, constructing, and installing overhead and riser poles in connection with the line break of Connecting Transmission Owner’s existing 69 kV transmission line. In addition, the Developer shall engineer, design, construct, and install, and the Connecting Transmission Owner shall procure, approximately 0.6 miles of 69 kV 2500 kcm cu XLPE cable to loop in (0.3 miles) and out (0.3 miles) of the existing transmission line into the ▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇▇▇ Substation. The Connecting Transmission Owner shall perform design review, oversee construction, test, and commission the facilities constructed by the Developer. ii. Protection SUF at Ridge Substation The Connecting Transmission Owner will perform line protection upgrades at the Ridge Substation on transmission line No. 69-883. The Ridge Substation will require the following major electrical equipment: • Line Current Differential Relay, ▇▇▇▇▇▇▇▇▇▇ Eng Lab Type SEL 311L, Cat. No. 0311L03D04254XXX; • Transmission Relay, ▇▇▇▇▇▇▇▇▇▇ Eng Lab Type SEL 321, Cat. No. 321114256HNB1X4; and • Tele Protection Relay, RFL Electronics Type 9745, Cat. No.TSHN65500. SERVICE AGREEMENT NO. 2344 iii. Protection SUF at Wildwood Substation The Connecting Transmission Owner will perform line protection upgrades at the Wildwood Substation on transmission line No. 69-883. The Wildwood Substation will require the following major electrical and physical equipment: • Line Current Differential Relay, ▇▇▇▇▇▇▇▇▇▇ Eng Lab Type SEL 311L, Cat. No. 0311L03D04254XXX; • Transmission Relay, ▇▇▇▇▇▇▇▇▇▇ Eng Lab Type SEL 321, Cat. No. 321114256HNB1X4; and • Tele Protection Relay, RFL Electronics Type 9745, Cat. No.TSHN65500. iv. Communication SUF The Developer shall be responsible for providing the following communication lines which shall be under the control of the Connecting Transmission Owner: • ▇▇▇▇▇-▇▇▇▇▇▇ substation - Verizon 4 wire lease line class 4A to be used for line protection via RFL 9745 at both ends. • Wildwood-▇▇▇▇▇▇ substation - Verizon 4 wire lease line class 4A to be used for line protection via RFL 9745 at both ends. • ▇▇▇▇▇▇ substation - Verizon 4 wire lease line class 3B to be used for SCADA communication. • ▇▇▇▇▇▇ substation - POTs lines ( ▇▇▇▇▇▇▇▇, ▇▇▇▇▇▇▇, sub phone). • Shoreham Solar to 8CS ▇▇▇▇▇▇ Street Substation - Fibers for line protection.

Appears in 2 contracts

Sources: Lgia No. 2344, Lgia No. 2344