Payments for Work Performed after the Effective Date of the Contract Price Proposal Clause Samples

Payments for Work Performed after the Effective Date of the Contract Price Proposal. For Work performed after the Effective Date of the Contract Price Proposal, Owner shall make progress payments within the time set forth in Section 5.4 below after Owner’s receipt of each properly submitted and accurate Application for Payment submitted in accordance with Paragraph 13.02 of the General Conditions. All such payments will be measured by the Progress Payment Schedule, pursuant to Paragraph 13.01 of the General Conditions, and shall reflect the total of payments previously made and amounts properly withheld as retainage, as set forth below, and under the Paragraph 13.03 of the General Conditions. Work completed as estimated shall be an estimate only and no inaccuracy or error in said estimate shall release DB Entity or any Surety from such work or from enforcing each and every provision of the Contract Documents. (1) Progress payments will be in an amount equal to ninety five percent (95%) of Work completed (with the balance as retention), and at the option of Owner, Owner may pay an amount equal to ninety five percent (95%) of materials and equipment not incorporated in the Work in place but delivered and suitably stored on Site, less in each case the aggregate of payments previously made. In no event shall payments for materials and equipment stored exceed ninety five percent (95%) of the value of the related cost for the specific item of work in place shown in the progress payment schedule regardless of the stated value of the materials or equipment. Owner may, at its sole option, pay an amount equal to ninety five percent (95%) of materials and equipment not incorporated in the work stored offsite if stored in a manner acceptable to Owner, as stated above for on-site stored materials. When payment to DB Entity is made for stored materials and equipment, DB Entity shall submit invoices marked paid by the supplier with the next month's request for payment to document that DB Entity has paid for said materials and equipment or the previously paid amount for stored materials shall be deducted from any remaining payment(s) or retainage for any stored materials not so properly documented. (2) The remaining five percent (5%) of such amounts shall be held as the Retention Amount and shall be released in accordance with Public Contract Code section 7107. If all of the necessary information is properly submitted, undisputed and accurate (including the progress payment schedule and certified payrolls), Owner shall approve the Progress Payment in acco...

Related to Payments for Work Performed after the Effective Date of the Contract Price Proposal

  • Modifications and Updates to the Wire Center List and Subsequent Transition Periods 5.4.6.1 In the event AT&T identifies additional wire centers that meet the criteria set forth in Sections 5.4.2.1 or 5.4.2.2 above, but that were not included in the Master List of Unimpaired Wire Centers or AT&T’s List of Unimpaired Wire Centers, AT&T shall include such additional wire centers in a CNL. Each such list of additional wire centers shall be considered a Subsequent Wire Center List. AT&T will follow any limitations on the frequency with which it may issue such lists and notification procedures set forth in applicable Commission orders. 5.4.6.2 TWTC shall have thirty (30) business days to dispute the additional wire centers listed on AT&T’s CNL. Absent such dispute, effective thirty (30) business days after the date of a AT&T CNL providing a Subsequent Wire Center List, AT&T shall not be required to provide DS1 and DS3 Dedicated Transport, as applicable, in such additional wire center(s), except pursuant to the self-certification process as set forth in Section 1.9.1 of this Attachment. 5.4.6.3 For purposes of Section 5.4.6.1 above, AT&T shall make available DS1 and DS3 Dedicated Transport that were in service for TWTC in a wire center on the Subsequent Wire Center List as of the thirtieth (30th) business day after the date of AT&T’s CNL identifying the Subsequent Wire Center List (Subsequent Embedded Base) until one hundred eighty (180) days after the thirtieth (30th) business day Version: 4Q06 Standard ICA 11/30/06 from the date of AT&T’s CNL identifying the Subsequent Wire Center List (Subsequent Transition Period). 5.4.6.4 The rates set forth in Exhibit B shall apply to the Subsequent Embedded Base during the Subsequent Transition Period. 5.4.6.5 No later than one hundred eighty (180) days from AT&T’s CNL identifying the Subsequent Wire Center List, TWTC shall submit an LSR(s) or spreadsheet(s) as applicable, identifying the Subsequent Embedded Base of circuits to be disconnected or converted to other AT&T services. 5.4.6.5.1 In the case of disconnection, the applicable disconnect charges set forth in this Agreement shall apply. 5.4.6.5.2 If TWTC chooses to convert DS1 and/or DS3 Dedicated Transport to special access circuits in existence as of the Effective Date of this Agreement, AT&T will include such DS1 and/or DS3 Dedicated Transport within TWTC’s total special access circuits, and apply any discounts to which TWTC is entitled from the transition period of 3/11/2006 to the conversion date. Conversions will be subject to the switch-as-is charge set forth in Exhibit A to this Attachment 2. 5.4.6.5.3 AT&T shall not impose disconnect or nonrecurring installation charges when transitioning the Subsequent Embedded Base of DS1 and DS3 Dedicated Transport in existence as of the Effective Date of this Agreement. 5.4.6.6 If TWTC fails to submit the LSR(s) or spreadsheet(s) for all of its Subsequent Embedded Base by one hundred eighty (180) days after the date of AT&T’s CNL identifying the Subsequent Wire Center List, AT&T will identify TWTC’s remaining Subsequent Embedded Base, if any, and will transition such circuits to the equivalent tariffed AT&T service(s), or in the case of Georgia, to the equivalent 271 service(s) set forth in Exhibit 1. In the states of Florida, Kentucky, Mississippi and South Carolina, those circuits identified and transitioned by AT&T shall be subject to the applicable disconnect charges as set forth in this Agreement and the full nonrecurring charges for installation of the equivalent tariffed AT&T service as set forth in AT&T’s tariffs. In the states of Alabama, Georgia, North Carolina and Tennessee, those circuits identified and transitioned by AT&T shall be subject to the applicable switch-as-is rates set forth in Exhibit A of Attachment

  • Commercial Operation Date Testing and Modifications Prior to the Commercial Operation Date, the Connecting Transmission Owner shall test the Connecting Transmission Owner’s Attachment Facilities (including required control technologies and protection systems) and System Upgrade Facilities and System Deliverability Upgrades and Developer shall test the Large Generating Facility and the Developer’s Attachment Facilities to ensure their safe and reliable operation. Similar testing may be required after initial operation. Developer and Connecting Transmission Owner shall each make any modifications to its facilities that are found to be necessary as a result of such testing. Developer shall bear the cost of all such testing and modifications. Developer shall generate test energy at the Large Generating Facility only if it has arranged for the injection of such test energy in accordance with NYISO procedures.

  • ADDITIONAL SPECIAL CONTRACT CONDITIONS Special Contract Conditions revisions: the corresponding subsections of the Special Contract Conditions referenced below are replaced in their entirety with the following:

  • Contract Effective Date This agreement becomes effective when signed by the last party whose signing makes the agreement fully executed.

  • Post-Commercial Operation Date Testing and Modifications Developer and Connecting Transmission Owner shall each at its own expense perform routine inspection and testing of its facilities and equipment in accordance with Good Utility Practice and Applicable Reliability Standards as may be necessary to ensure the continued interconnection of the Large Generating Facility with the New York State Transmission System in a safe and reliable manner. Developer and Connecting Transmission Owner shall each have the right, upon advance written notice, to require reasonable additional testing of the other Party’s facilities, at the requesting Party’s expense, as may be in accordance with Good Utility Practice.