Physical, Mechanical, and Electrical Properties Clause Samples

Physical, Mechanical, and Electrical Properties. The wire shall conform to the properties listed in Table 2. Density (ASTM D 792) 0.943 g/cc Bulk Density (ASTM D 1895) 0.58 g/cc Melt Index (ASTM D 1238/E) 0.70 dg/min Tensile-Yield (ASTM D 638) 4300 psi Tensile-Ultimate (ASTM D 638) 2900 psi Tensile-Elongation (ASTM D 638) 850% Flexural Modulas (ASTM D 790/1) 120,000 psi Hardness (ASTM D 2240) 63 Shore D Environmental Stress-Crack (ASTM D 1693/B) F20 > 48 h Thermal Stress-Crack (ASTM D2951) F0 > 1000 h Brittleness Temperature (ASTM D 746) < -95° F Melting Point (DSC) (ASTM D 3417) 262° F Softening Point (Vicat) (ASTM D 1525) 250° F Oxidative Induction Time (ASTM D 3895) > 50 min. @ 200° C Dielectric Constant (ASTM D 1531) 2.34 @ 1MHz Dissipation Factor (ASTM D 1531) 0.00007 @ 1 MHz Volume Resistivity (ASTM D 257) 5 x 1017 ohm-cm Dielectric Strength (ASTM D 3755) 1000 volts @ 20 mils
Physical, Mechanical, and Electrical Properties. The wire shall conform to the properties listed in Table 1. Conductor Size 12 AWG Conductor Type Copper Clad Steel (CCS) Temper Hard Drawn (HD) Average Break Load 1150 lbs. Minimum Tensile Strength 200,000 psi Minimum Elongation 1.0% Copper Thickness (% of Diameter) 3.0% Minimum Copper Weight 13% Nominal DC Resistance (ohms/1000 ft.) 7.5648

Related to Physical, Mechanical, and Electrical Properties

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • Electrical Power Corporation shall provide Contractor with convenient access to electrical power required to perform the work. The electrical outlets used by Contractor shall be those designated or approved by Corporation.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • Mechanical (i) Large scale mechanical details complete. (ii) Mechanical schedules for equipment completed. (iii) Completed electrical schematic for environmental cooling and exhaust equipment. (iv) Complete energy conservation calculations and report.

  • Installation, Maintenance, Testing and Repair Unless otherwise agreed in writing by the Parties, to the extent required by Applicable Law, Interconnection provided by a Party shall be equal in quality to that provided by such Party to itself, any subsidiary, affiliates or third party. If either Party is unable to fulfill its obligations under this Section 14.2, it shall notify the other Party of its inability to do so and will negotiate alternative intervals in good faith. The Parties agree that to the extent required by Applicable Law, the standards to be used by a Party for isolating and clearing any disconnections and/or other outages or troubles shall be at parity with standards used by such Party with respect to itself, any subsidiary, affiliate or third party.