PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION Sample Clauses

PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. ‌ A. Plan Submission Requirements‌ All identified plans and submissions must adhere to the requirements and obligations set forth in relevant regulations, this Agreement, the Revised MDNS, and the ASC. Unless otherwise noted, all plans and submissions required prior to beginning site construction activities are required to be filed with EFSEC ninety (90) days prior to the start of Construction. The Certificate Holder shall not begin Construction activities until all applicable elements of the required plans or commitments outlined in this Agreement, the Revised MDNS, and the ASC are in place, and Council approval of required plans and authorization to begin construction has been obtained. B. Notice of Federal, State, and Local Permit Approvals‌ No later than thirty (30) days after the effective date of this Agreement, the Certificate Holder shall notify the Council of all Federal, State, and Local permits, not delegated to EFSEC, that are required for construction and operation of the Project, if any, and the anticipated date of permit issuance to the Certificate Holder. The Certificate Holder shall notify the Council when all required permits have been obtained, no later than ten (10) business days after the permit has been issued. C. Mitigation MeasuresDuring construction, operation, decommissioning, and site restoration of this Project, the Certificate Holder shall implement the mitigation measures set forth in this Agreement, including, but not limited to, those presented in the ASC and those identified in the Revised MDNS. For each of these mitigation measures, the Certificate Holder shall in the same filing further identify the Construction Plan and/or Operation Plan addressing the methodology for its achievement. The specific plans and submittals listed in the remainder of this Article IV, and Articles V, VI, VII, and VIII, shall incorporate these mitigation measures as applicable.
PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. ‌ A. Notice of Federal Permit Approvals‌ No later than thirty (30) days after the effective date of this Agreement, the Certificate Holder shall notify the Council of all Federal permits, not delegated to EFSEC, that are required for construction and operation of the Project, if any, and the anticipated date of permit issuance to the Certificate Holder. The Certificate Holder shall notify the Council when all required federal permits have been obtained, no later than ten (10) business days after the last permit has been issued.
PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. A. Plan Submission Requirements B. Notice of Federal, State, and Local Permit Approvals
PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. Habitat, Vegetation, and Fish and Wildlife Mitigation
PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. A. Notice of Federal Permit Approvals
PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION. The following plans, submittals and/or approvals shall be submitted to the Council a minimum of ninety (90) days prior to the beginning of construction, unless otherwise specified below: A. Right-of-Way Map A detailed map showing right-of-way acquisition and land uses impacted within the right-of-way will be submitted to EFSEC and WUTC ninety (90) days prior to the beginning of construction of the Pipeline and the electrical transmission line. B. Initial Site Restoration Plan At least ninety (90) days prior to the beginning of site preparation, the Certificate Holder shall submit to the Council its initial site restoration plan, which will provide for the funding of site restoration at the end of the S2GF's useful operating life or in the event of the S2GF being terminated before it has completed its useful operating life. At a minimum, the initial site restoration plan shall address both the possibility that site restoration occurs at the end of the useful life of the S2GF and also the possibility of the S2GF being suspended or terminated during construction. The plan shall comply with the Council’s rules and shall include at least the following components: 1. A description of the assumptions underlying the plan. For example, the plan should explain the anticipated useful life of the S2GF, the anticipated time frame of site restoration, and the anticipated future use of the Site. 2. An initial plan for demolishing facilities, salvaging equipment, and disposing of waste materials. 3. An initial plan for disposing of hazardous materials (if any) present on the Site, and remediating hazardous contamination (if any) at the site. 4. An initial plan for restoring the Site, including the removal of structures and foundations and the regrading of the Site, if appropriate. 5. The provision of financial assurances to ensure that funding is available and sufficient for site restoration. Such financial assures will include evidence of pollution liability insurance coverage in an amount not less than ten million dollars ($10,000,000), and a site closure bond or other financial instrument or security in an amount justified in the initial site restoration plan. 6. Provisions for retaining systems owned and operated by the City of Sumas. 7. Provisions for retaining and protecting wetlands mitigation sites. 8. Provisions for restoration of the electrical transmission line and natural gas pipeline. Prior to beginning site preparation, the Certificate Holder must obtain app...

Related to PLANS, APPROVALS AND ACTIONS REQUIRED PRIOR TO CONSTRUCTION

  • No Consents Required No consent, approval, authorization, order, registration or qualification of or with any court or arbitrator or governmental or regulatory authority is required for the execution, delivery and performance by the Company of this Agreement, the issuance and sale of the Shares and the consummation of the transactions contemplated by this Agreement, except for the registration of the Shares under the Securities Act and such consents, approvals, authorizations, orders and registrations or qualifications as may be required by the Financial Industry Regulatory Authority, Inc. (“FINRA”) and under applicable state securities laws in connection with the purchase and distribution of the Shares by the Underwriters.

  • Authorization Required Prior to Parallel Operation 2.2.1 The NYISO, in consultation with the Connecting Transmission Owner, shall use Reasonable Efforts to list applicable parallel Operating Requirements in Attachment 5 of this Agreement. Additionally, the NYISO, in consultation with the Connecting Transmission Owner, shall notify the Interconnection Customer of any changes to these requirements as soon as they are known. The NYISO and Connecting Transmission Owner shall make Reasonable Efforts to cooperate with the Interconnection Customer in meeting requirements necessary for the Interconnection Customer to commence parallel operations by the in-service date. 2.2.2 The Interconnection Customer shall not operate its Small Generating Facility in parallel with the New York State Transmission System or the Distribution System without prior written authorization of the NYISO. The NYISO, in consultation with the Connecting Transmission Owner, will provide such authorization once the NYISO receives notification that the Interconnection Customer has complied with all applicable parallel Operating Requirements. Such authorization shall not be unreasonably withheld, conditioned, or delayed.