ADDITIONAL SPECIAL CONTRACT CONDITIONS Special Contract Conditions revisions: the corresponding subsections of the Special Contract Conditions referenced below are replaced in their entirety with the following:
Traffic Measurement and Billing over Interconnection Trunks 6.1 For billing purposes, each Party shall pass Calling Party Number (CPN) information on at least ninety-five percent (95%) of calls carried over the Interconnection Trunks. 6.1.1 As used in this Section 6, “Traffic Rate” means the applicable Reciprocal Compensation Traffic rate, Measured Internet Traffic rate, intrastate Switched Exchange Access Service rate, interstate Switched Exchange Access Service rate, or intrastate/interstate Tandem Transit Traffic rate, as provided in the Pricing Attachment, an applicable Tariff, or, for Measured Internet Traffic, the FCC Internet Order. 6.1.2 If the originating Party passes CPN on ninety-five percent (95%) or more of its calls, the receiving Party shall ▇▇▇▇ the originating Party the Traffic Rate applicable to each relevant minute of traffic for which CPN is passed. For any remaining (up to 5%) calls without CPN information, the receiving Party shall ▇▇▇▇ the originating Party for such traffic at the Traffic Rate applicable to each relevant minute of traffic, in direct proportion to the minutes of use of calls passed with CPN information. 6.1.3 If the originating Party passes CPN on less than ninety-five percent (95%) of its calls and the originating Party chooses to combine Reciprocal Compensation Traffic and Toll Traffic on the same trunk group, the receiving Party shall ▇▇▇▇ the higher of its interstate Switched Exchange Access Service rates or its intrastate Switched Exchange Access Services rates for all traffic that is passed without CPN, unless the Parties agree that other rates should apply to such traffic. 6.2 At such time as a receiving Party has the capability, on an automated basis, to use such CPN to classify traffic delivered over Interconnection Trunks by the other Party by Traffic Rate type (e.g., Reciprocal Compensation Traffic/Measured Internet Traffic, intrastate Switched Exchange Access Service, interstate Switched Exchange Access Service, or intrastate/interstate Tandem Transit Traffic), such receiving Party shall ▇▇▇▇ the originating Party the Traffic Rate applicable to each relevant minute of traffic for which CPN is passed. If the receiving Party lacks the capability, on an automated basis, to use CPN information on an automated basis to classify traffic delivered by the other Party by Traffic Rate type, the originating Party will supply Traffic Factor 1 and Traffic Factor
Delivery Conditions Each delivery of the Goods shall be accompanied with a delivery note, which shall be confirmed by both Parties upon handover and takeover of the Goods, and shall be used as the Goods handover protocol. The delivery note shall contain: identification data of the Seller and the Buyer, the number and date of issue of the Delivery Note, position/serial number according to the Contract; contract number; Material code according to IS in STC format; the number of the supplied units without defects with a divided according to individual types, the number of delivered pieces of defective Prelaminates according to paragraph 5 of this article, the total number of Prelaminates delivered, place and date of handover and acceptance (hereinafter the "delivery note") The Seller shall notify the Buyer to the e-mail address: ▇▇▇▇▇▇▇▇▇▇@▇▇▇.▇▇ the expected date and time when the Goods will be delivered to the Buyer's address, at least 2 working days before the day of dispatch from the Seller's plant. In the event that the Seller uses a carrier that allows you to monitor the status of the delivery, the Seller will also send the Buyer the number of the bill of lading. The Seller shall immediately inform the Buyer about expected failure to arrive on time in order to solve this situation. The Seller shall deliver the Goods on business days and during the Buyer's regular working hours, i.e. between 6:00 a.m. and 2:00 p.m., unless stipulated otherwise by the Buyer. Outside these hours, it is only possible to receive Goods following a previous agreement made over the phone between the Seller and the Buyer's representative stated in this Contract. Within a single delivery must not content: a) the number of defective Prelaminates higher than 2% of the total number of Prelaminates delivered, b) no sheet in the format of 3x7 positions, on which the number of defective Prelaminates will be greater than 2, Within one partial delivery, the tolerance of the number of delivered Prelaminates is +/- 3% of the ordered number of Prelaminates. The Seller undertakes to provide the subject of performance for transport and subsequent storage in a manner that is usual for this type of subject of performance in business relations so as to ensure the preservation, protection and quality of the subject of performance. Each delivered consignment will be properly marked with the indication of the subject of performance, the manufacturer and information about its weight. The performance of the Seller is considered fulfilled if it is delivered on time and properly, i.e. free of any defects in quantity in accordance with the agreement of the Parties under paragraph 6 of this article, quality or legal defects, including accompanying written documents. The ownership title to the Goods supplied on the basis of this Contract shall pass on the Buyer at the moment of takeover of the Goods, i.e. at the moment the handover protocol for the Goods (delivery note) is signed by the Buyer. The risk of damage to the Goods shall pass to the Buyer at the same moment.
Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.
Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.