The Quantity Measurement clause defines how the amount of goods, materials, or services delivered under a contract will be determined and verified. Typically, it outlines the methods, units of measurement, and procedures for recording and confirming quantities, such as through weigh tickets, delivery receipts, or third-party verification. This clause ensures both parties have a clear, agreed-upon process for measuring deliverables, thereby reducing disputes and providing a reliable basis for payment and performance evaluation.
POPULAR SAMPLE Copied 2 times
Quantity Measurement. 6.1 The invoice quantity shall be determined by DSC based on the reading given by its calibrated flow meters, corrected for temperature.
6.2 DSC shall be responsible for the upkeep and maintenance of its calibrated flow meters.
6.3 DSC shall arrange for the testing and calibration of all its tanks and calibrated flow meters on a regularly scheduled basis.
6.4 If at any time PURCHASER has reasonable grounds to suspect that any measuring equipment is not accurate in any respect, the discrepancy or suspected discrepancy shall be immediately reported to DSC in writing along with any evidence in support of such claim and DSC shall arrange for the testing of the relevant piece of measuring equipment.
6.5 If any piece of measuring equipment fails to register or, upon test, is found not to be within +/- 0.5 percent accuracy then, for the purposes of this Agreement, a reasonable adjustment in accordance with generally accepted engineering practices shall be made correcting all measurements made with that piece of measuring equipment. Such adjustments shall reflect, if determinable, the actual period during which any inaccurate measurements were made. If such period cannot be determined it shall be deemed to be such period as shall be equal to one-half of the time from the date of the previous test of such measurement equipment, provided that the period covered by any such correction shall not exceed 6 months.
Quantity Measurement. The quantity of Ethanol delivered to Cargill shall be established by outbound meter tickets obtained by Producer and expressed in net temperature-corrected gallons in accordance with standards commonly used within the industry in the United States of America. The meter tickets shall be obtained from meters which are certified as of the time of loading and which comply with all applicable laws, rules, and regulations. The outbound meter tickets shall be determinative in absence of manifest error (greater than 0.5% variation) of the quantity of Ethanol for which Cargill is obligated to pay. In the event of manifest error, the Parties will try to resolve such dispute on a commercial level. If the Parties cannot resolve the dispute in such manner, the Parties will resolve the dispute in accordance with Section 7 of the Master Agreement. At Cargill’s request, Producer shall provide Cargill with documentation of the Ethanol Facility’s Ethanol Production.
Quantity Measurement. Quantity measurements shall be taken at HCU 942 meter -------------------- FQ-2251. The following meters shall be used as input to the above calculations: Light Cycle Oil to HCU 942: XX-XXXX EXHIBIT A-19 Heavy Gas Oil from DCU 843 to HCU 942: DCU 843 FE-1000 Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942: HCU 942 FQ-1020 Quality Measurement: Grab samples shall be taken at least (1) time per day and ------------------- analyzed by ▇▇▇▇▇▇▇ and at least (3) times per week and analyzed by gas chromatography. EXHIBIT A-20 Product: Light Naphtha from HCU 942 ------- Target Specification: --------------------- Property Specification Test Method -------- ------------- ----------- Propane 0.17% LV Typical UOP-539 Isobutane 1.59% LV Typical UOP-539 Normal Butane 1.56% LV Typical UOP-539 Butane and Lighter 5.00% LV Maximum UOP-539 ▇▇▇▇ Vapor Pressure @ 100 degrees F 13.5 PSIG Maximum ASTM D-5191 (▇▇▇▇▇▇▇) Quantity: ▇▇▇▇▇ Company shall sell and ▇▇▇▇▇ shall purchase the portion of this -------- Product produced by ▇▇▇▇▇ Company feedstocks in HCU 942. That portion is calculated as follows:
Quantity Measurement. Quantity measurements shall be taken at HCU 942 meter -------------------- FQ-2575. The following meters shall be used as input to the above calculations: Light Cycle Oil to HCU 942: XX-XXXX Heavy Gas Oil from DCU 843 to HCU 942: DCU 843 FE-1000 Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942: HCU 942 FQ-1020 Quality Measurement: Grab samples shall be taken (3) times per week and analyzed ------------------- for each specification. Product Purchase Agreement Page 35 August 3, 1999 EXHIBIT A-23 Product: Diesel from HCU 942 ------- Target Specification: -------------------- Property Specification Test Method -------- ------------- ----------- API Gravity 30.0 Minimum ASTM D-1298, ASTM D-287, or ASTM D-4052 Corrosion 3 hrs. @ 212 degrees F 1 Maximum ASTM D-130 Viscosity @ 100 degrees F 2.0 cSt Minimum ASTM D-445 Viscosity @ 100 degrees F 3.6 cSt Maximum ASTM D-445 Flash Point 130 degrees F Minimum ASTM D-56 90% 540 degrees F Minimum ASTM D-86 90% 640 degrees F Maximum ASTM D-86 FBP 690 degrees F Maximum ASTM D-86 Color 2.5 Maximum ASTM D-1500 Cloud (September-March) 15 degrees F Maximum ASTM D-2500, ASTM D-5771, or ASTM D-5773 Cloud (April-August) 20 degrees F Maximum ASTM D-2500, ASTM D-5771, or ASTM D-5773 Pour (September-March) 0 degrees F Maximum ASTM D-97, ASTM D-5949, or ASTM D-5950 Pour (April-August) 10 degrees F Maximum ASTM D-97, ASTM D-5949, or ASTM D-5950 Sulfur 0.047 wt% Maximum ASTM D-2622 Cetane Index 42 Minimum ASTM D-976 Ash 0.01 wt% Maximum ASTM D-482 Carbon Residue (Ramsbottom on 10% Bottom) 0.35 Maximum ASTM D-524 BS&W 0.05 Maximum ASTM D-1796 Haze Rating @ 77 degrees F (Procedure 2) 2 Maximum ASTM D-4176 Thermal Stability 90 Minutes 150 degrees C Pad Rating 7 Maximum Dupont Scale OR Oxidation Stability 2.5 mg/100 ml Maximum ASTM D-2274 * Denotes less than Target specifications are based on current fungible transportation diesel fuel namely Colonial 74 Grade Low Sulfur Diesel Fuel. To the extent the specifications change for Colonial 74 Grade Low Sulfur Diesel Fuel the target specifications will be changed accordingly. Quantity: ▇▇▇▇▇ Company shall sell and ▇▇▇▇▇ shall purchase the portion of this -------- Product produced by ▇▇▇▇▇ Company feedstocks in HCU 942. That portion is calculated as follows: ▇▇▇▇▇ Company Diesel = Total Diesel * ( Heavy Gas Oil from AVU 146 to HCU EXHIBIT A-23
Quantity Measurement. The quantity of Ethanol Delivered to Buyer by Seller from the Plant shall be established by outbound meter tickets expressed in net temperature-corrected Gallons in accordance with standards commonly used within the industry in the United States of America. The meter tickets shall be obtained from meters which are certified as of the time of loading and which comply with all applicable laws, rules and regulations. The outbound meter tickets shall be determinative in the absence of manifest error [***] of the quantity of Ethanol for which Buyer is obligated to pay pursuant to Section 10.1.
Quantity Measurement. Quantity measurements shall be taken at DCU 843 meter -------------------- FE-3210. Quality Measurement: Grab samples shall be taken at least (1) time per day and ------------------- analyzed by draeger and at least (3) times per week and analyzed by gas chromatography, MDA Sulfur, and Antek Nitrogen. EXHIBIT A-13 Product: Untreated Naphtha from DCU 843 ------- Target Specification: -------------------- Property Specification Test Method -------- ------------- ----------- FBP 390 degrees F Maximum ASTM D-86 N+A 25.5% LV Typical ASTM D-5134 - Modified to C-15 Existent Washed Gums 1 mg/100 ml Maximum ASTM D-381 Oxygen Stability 360+ Minimum ASTM D-525 Silica 1.5 ppmw Maximum UOP-484 Quantity: For days that Naphtha from DCU 843 is not treated in the Naphtha -------- Hydrotreater 1344, ▇▇▇▇▇ Company shall sell and ▇▇▇▇▇ shall purchase the "▇▇▇▇▇ Company Share" of the Untreated Naphtha from DCU 843 as defined below. The ▇▇▇▇▇ Company Share is defined as the Untreated Naphtha from DCU 843 multiplied by the ▇▇▇▇▇ Company Crude Oil Volume divided by the Total Crude Oil Volume. Untreated Naphtha from DCU 843 = Total Naphtha from DCU 843 - ▇▇▇▇▇ Naphtha to Naphtha Hydrotreater 1344 Price: The arithmetic average of the high/low Oil Price Information Service ----- posting for spot purchases of U. S. Gulf Coast Naphtha (Domestic 40 N+A) for each publication day less 0.15 cents/gallon/N+A number below 40 N+A plus 0.15 cents/gallon/N+A number above 40 N+A less 4.0 cents/gallon. The price for non-publication day deliveries shall be the arithmetic average of the prices for the last proceeding publication day and the next following publication day.
Quantity Measurement. Quantity measurements shall be taken at DCU 843 meter -------------------- FE-3271. Quality Measurement: Grab samples shall be taken at least (1) time per day and ------------------- analyzed by draeger and at least (3) times per week and analyzed by gas chromatography. EXHIBIT A-12 Product: Butane/Butylene Mix from DCU 843 ------- Component Specification Test Method --------- ------------- ----------- H2S 5 ppmw Maximum Draeger Sulfur 50 ppmw Maximum ASTM D-4045 Total Nitrogen 1 ppmw Maximum ASTM D-4629 Propane and Lighter 6.0% LV Maximum ASTM ▇-▇▇▇▇ ▇▇▇▇▇▇▇ and Heavier 5.0% LV Maximum ASTM ▇-▇▇▇▇ ▇▇▇▇▇▇ and Heavier 0.05% LV Maximum ASTM D-2163 Butadiene 0.35% LV Maximum ASTM D-2163 Isobutane 13.0% LV Typical ASTM D-2163 Normal Butane 47.0% LV Typical ASTM D-2163 Butylenes 40.0% LV Typical ASTM D-2163 Quantity: ▇▇▇▇▇ Company shall sell and ▇▇▇▇▇ shall purchase the "▇▇▇▇▇ Company -------- Share" of the total output of this Product. The ▇▇▇▇▇ Company Share is defined as the output of this product multiplied by the ▇▇▇▇▇ Company Crude Oil Volume divided by the Total Crude Oil Volume.
Quantity Measurement. 9.1 Actual measurement of quantities of products delivered and the supplied party's rights to dispute such measurements will be as set out in Schedule "E".
Quantity Measurement. Quantity measurements shall be calculated by changes in -------------------- Unfinished Diesel inventory utilizing standard yield accounting methods. The following meters shall be used as input to the above calculations: Total Light Cycle Oil from FCCU 1241: FCCU 1241 FC-1247 Light Cycle Oil to Cutter: Pump St. 379 FRC-201 Light Cycle Oil to HCU 942: XX-XXXX Diesel Charge to GFU 241: XX-XXXX Diesel from AVU 146: See Attachment I Light Gas Oil from DCU 843: See Attachment II Quality Measurement: Quality measurements for each component is described in ------------------- Attachments I and II below. Attachment I ------------ Component: Diesel from AVU 146 --------- Product Purchase Agreement Page 8 August 3, 1999 EXHIBIT A-5 Target Specification: --------------------- Property Specification Test Method -------- ------------- ----------- 90% 540 Degrees F Minimum ASTM D-86 90% 640 Degrees F Maximum ASTM D-86 FBP 690 Degrees F Maximum ASTM D-86 Flash Point 130 Degrees F Minimum ASTM D-93 Target specifications are based on current fungible transportation diesel fuel namely Colonial 74 Grade Low Sulfur Diesel Fuel. To the extent the specifications change for Colonial 74 Grade Low Sulfur Diesel Fuel the target specifications will be changed accordingly.
Quantity Measurement. Quantity measurements of the Stripper Off Gas from Naphtha -------------------- Hydrotreater 1344 shall be taken at CCR 1344 meter FR-864. The following meters shall be used as input to the above calculations: ▇▇▇▇▇ Naphtha to Naphtha Hydrotreater 1344: CCR FRC-601 Total Naphtha Hydrotreater Feed: CCR FR-677 Quality Measurement: Grab samples shall be taken at least (3) times per week and ------------------- analyzed by gas chromatography. Product Purchase Agreement Page 43 August 3, 1999 EXHIBIT A-26 Product: Treated Naphtha from Naphtha Hydrotreater 1344 ------- Target Specification: -------------------- Component Specification Test Method --------- ------------- ----------- Sulfur 0.5 ppmw ASTM ▇-▇▇▇▇ ▇▇▇▇▇▇▇▇ 0.5 ppmw ASTM D-4629 Doctor Negative ASTM D-4952 Quantity: ▇▇▇▇▇ Company shall sell and ▇▇▇▇▇ shall purchase the portion of this -------- Product produced by ▇▇▇▇▇ Company feedstocks in Naphtha Hydrotreater 1344. That portion is calculated as follows: