Rack Space. Lessor hereby leases to lessee one (1) standard rack (24 5/16 W x 15 D x 7 H) space for the purpose of installing electronic equipment to permit Lessee to receive and deliver communications traffic to and from Lessor's telecommunications network. Such rack space shall be located within the Customer Interface ("CIF") Room at Lessor's building site (the "Premises") at the address shown below. Delivery of such communications traffic shall be to the Lessor's point of demarcation in the Lessor's equipment room. The point of demarcation shall be a DSX1 or DSX3 as applicable. Signals received at this demarcation shall meet the then current DSX signal specification. Material and installation to the demarcation interconnect shall meet IXC approved technical standards and shall be at the Lessee's expense. Any voice grade facilities (two wire copper) are not typically available and are excluded from installation under this agreement. The equipment installed by the Customer must meet IXC installation standards, as well as all National Electrical Codes (NEC), any local fire and safety codes and any other applicable safety standards and is subject to inspection by IXC personnel. Deficiencies or code violations must be corrected within thirty (30) days of notification or Lessee will be considered in breach of this Agreement. (A copy of IXC Installation Standards will be available upon request). ▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇▇, ▇▇▇▇▇ ▇▇▇▇ ▇▇▇ ▇▇▇▇▇▇▇, ▇▇▇▇▇▇▇▇▇▇ Lessor shall provide (i) twenty (20) amps non-UPS AC power at the above site and provide access to an AC outlet for test equipment and occasional use; (ii) lighting; (iii) heating; and (iv) air conditioning for the Premises (collectively, the "Services").
Appears in 1 contract
Sources: Rack Space Agreement (Startec Global Communications Corp)
Rack Space. Lessor hereby leases to lessee Lessee one (1) standard rack (24 5/16 W w x 15 D x 7 H) space spaces for the purpose of installing electronic equipment to permit Lessee to receive and deliver communications traffic to and from Lessor's telecommunications network. Such rack space shall be located within the Customer Interface ("CIF") Room at Lessor's building site (the "Premises") at the address shown below. Delivery of such communications traffic shall be to the Lessor's point of demarcation in the Lessor's equipment room. The point of demarcation shall be a DSX1 or DSX3 as applicable. Signals received at this demarcation shall meet the then current DSX signal specification. Material and installation to the demarcation interconnect shall meet IXC approved technical standards and shall be at the Lessee's expense. Any voice grade facilities (two wire copper) are not typically available and are excluded from installation under this agreement. The equipment installed by the Customer must meet IXC installation standards, as well as all National Electrical Codes (NEC), any local fire and safety codes and any other applicable safety standards and is subject to inspection by IXC personnel. Deficiencies or code violations must be corrected within thirty (30) days of notification or Lessee will be considered in breach of this Agreement. (A copy of IXC Installation Standards will be available upon request). ▇▇▇▇ ▇▇▇▇▇ ▇▇▇▇▇▇▇ ▇▇▇▇▇▇ ▇▇▇▇▇▇, ▇▇▇▇▇ ▇▇▇▇ ▇▇▇ ▇▇▇▇▇▇▇, ▇▇▇▇▇▇▇▇▇▇ Lessor shall provide (i) twenty (20) amps DC power and twenty (20) amps non-UPS AC power at the above site and provide access to an AC outlet for test equipment and occasional use; (ii) lighting; (iii) heating; and (iv) air conditioning for the Premises (collectively, the "Services").
Appears in 1 contract
Sources: Rack Space Agreement (Startec Global Communications Corp)