Receipt Point Gas Quality Specifications. Gas delivered by or for the account of Shipper to each Receipt Point shall meet the following specifications (collectively, the “Gas Quality Specifications”): (a) less than [***] mole percent of carbon dioxide; (b) not more than [***] grain H2S per [***] Cubic Feet; (c) not more than [***] grain of mercaptan sulphur per [***] Cubic Feet; (d) a Gross Heating Value per Cubic Foot of not less than [***] BTU; (e) not more than a total of [***] mole percent of total inert or non-hydrocarbon gases (nitrogen, carbon dioxide, etc.); provided that for purposes of the total inert specification, such [***] mole percent total inert specification shall apply based on the aggregate volume weighted average Receipt Point quality; (f) not more than [***] grains of sulfur per [***] cubic feet (including hydrogen sulfide and mercaptan); (g) an oxygen content not in excess of [***]% by volume; provided that the Parties shall use every reasonable effort to keep the gas free from oxygen; (h) a temperature not to exceed [***] degrees Fahrenheit; and (i) free of water, crude and/or Condensate in the liquid phase, impurities and other objectionable substances; provided that to the extent the quality specifications required from time to time by the Downstream Pipelines receiving Residue Gas are more restrictive than any of the foregoing requirements (except for water vapor content, Gross Heating Value and hydrocarbon dew point for such Downstream Pipelines), then the quality specifications required by the Downstream Pipeline shall apply instead of the foregoing applicable specification. Neither Gatherer nor Shipper will propose or support any changes to the Downstream Pipeline specifications that would result in more restrictive specifications. Notwithstanding the foregoing, if Gatherer connects the Facilities to a Downstream Pipeline other than Northern Border or WBI, the more restrictive specifications of such downstream pipeline shall not apply to Shipper without Shipper’s approval.
Appears in 1 contract
Sources: Gas Gathering, Compression, Processing and Gas Lift Agreement (Oasis Midstream Partners LP)
Receipt Point Gas Quality Specifications. Gas delivered by or for the account of Shipper to each Receipt Point shall meet the following specifications (collectively, the “Gas Quality Specifications”):
(a) less than [***] mole percent of carbon dioxide;
(b) not more than [***] grain H2S per [***] Cubic Feetcubic feet;
(c) not more than [***] grain of mercaptan sulphur per [***] Cubic Feetcubic feet;
(d) a Gross Heating Value gross heating value per Cubic Foot of not less than [***] BTU;
(e) not more than a total of [***] mole percent of total inert inerts or non-hydrocarbon gases (nitrogen, carbon dioxide, etc.); provided that for purposes of the total inert specification, such [***] mole percent total inert specification shall apply based on the aggregate volume weighted average Receipt Point quality;
(f) not more than [***] grains of sulfur per [***] cubic feet (including hydrogen sulfide and mercaptan);
(g) an oxygen content not in excess of [***]% by volume; provided that the Parties shall use every reasonable effort to keep the gas free from oxygen;
(h) a temperature not to exceed [***] degrees Fahrenheit; and
(i) free of water, crude and/or Condensate condensate in the liquid phase, impurities and other objectionable substances; provided that to the extent the quality specifications required from time to time by the Downstream Pipelines receiving Residue Gas are more restrictive than any of the foregoing requirements (except for water vapor content, Gross Heating Value gross heating value and hydrocarbon dew point for such Downstream Pipelines), then the quality specifications required by the Downstream Pipeline shall apply instead of the foregoing applicable specification. Neither Gatherer nor Shipper will propose or support any changes to the Downstream Pipeline specifications that would result in more restrictive specifications. Notwithstanding the foregoing, if Gatherer connects the Facilities to a Downstream Pipeline other than Northern Border or WBI, the more restrictive specifications of such downstream pipeline shall not apply to Shipper without Shipper’s approval.
Appears in 1 contract
Sources: Gas Gathering, Compression, Processing and Gas Lift Agreement (Oasis Midstream Partners LP)
Receipt Point Gas Quality Specifications. Gas delivered by or for the account of Shipper to each Receipt Point shall meet the following specifications (collectively, the “Gas Quality Specifications”):
(a) less than [***] two mole percent of carbon dioxide;
(b) not more than [***] 1/4 grain H2S per [***] 100 Cubic Feet, such 1/4 grain H2S per 100 Cubic Feet specification shall apply based on the aggregate volume weighted average Receipt Point quality as calculated upstream of each System Compressor Station [omitted];
(c) not more than [***] 1/4 grain of mercaptan sulphur per [***] 100 Cubic Feet, such 1/4 grain mercaptan sulphur per 100 Cubic Feet specification shall apply based on the aggregate volume weighted average Receipt Point quality as calculated upstream of each System Compressor Station;
(d) a Gross Heating Value per Cubic Foot of not less than [***] 1,100 BTU;
(e) not more than a total of [***] three mole percent of total inert or non-hydrocarbon gases (nitrogen, carbon dioxide, etc.)) and contain no more than 2.0% by volume carbon dioxide; provided that for purposes of the total inert specificationspecification and carbon dioxide, such [***] three mole percent total inert specification and 2.0% carbon dioxide specification shall apply based on the aggregate volume weighted average Receipt Point quality;
(f) not more than [***] two grains of total sulfur per [***] cubic feet 100 Cubic Feet (including hydrogen sulfide and mercaptan), such two grains of total sulfur per 100 Cubic Feet specification shall apply based on the aggregate volume weighted average Receipt Point quality as calculated upstream of each System Compressor Station;
(g) an oxygen content not in excess of [***]0.001% by volume; provided that the Parties shall use every reasonable effort to keep the gas free from oxygen;
(h) a temperature not to exceed [***] 100 degrees Fahrenheit; and
(i) free of water, crude and/or Condensate in the liquid phase, impurities and other objectionable substances; provided that to the extent the quality specifications required from time to time by the Downstream Pipelines receiving Residue Gas are more restrictive than any of the foregoing requirements (except for water vapor content, Gross Heating Value and hydrocarbon dew point for such Downstream Pipelines), then the quality specifications required by the Downstream Pipeline shall apply instead of the foregoing applicable specification. Neither Gatherer nor Shipper will propose or support any changes to the Downstream Pipeline specifications that would result in more restrictive specifications. Notwithstanding the foregoing, if Gatherer connects the Facilities to a Downstream Pipeline other than Northern Border or WBI, the more restrictive specifications of such downstream pipeline shall not apply to Shipper without Shipper’s approval[Omitted].
Appears in 1 contract
Sources: Gas Gathering, Compression and Processing Agreement (Oasis Midstream Partners LP)