ROOF STRUCTURE. The Building Shell roof structure shall be constructed using metal columns, girders and joists, with wood framing members, and wood roof decking. Building structure clear height (lowest structural element) shall be 15 feet. The Building Shell roof structure shall be insulated with Code-required rigid insulation and shall remain exposed. Painting of roof structure and supporting elements, if required, is part of tenant improvement work. Metal stud furring and gypsum board for roof columns, if required, are part of tenant improvement work. EXTERIOR ENTRIES AND MAN DOORS: Building Shell doors are included as shown on drawings or exhibits. Doors in aluminum systems include single or double storefront doors with push-pull hardware, crash bar panic hardware and surface- mounted closers.