Payment Options Paper Invoice - Supplier submits a paper invoice to the organisation as standard for each purchase order received. Embedded Purchase Card - This payment option allows the supplier to charge the cost of the goods/services provided to a VISA/MasterCard electronic Purchasing Card (ePC) belonging to a Contracting Authority. The supplier shall receive payment from VISA/MasterCard therefore negating the need to provide an invoice to the Contracting Authority. Consolidated Electronic Invoice - Supplier submits a single invoice covering multiple purchase orders in an electronic file. Self-Billing - Once the Goods Received Note (GRN) has been entered on PECOS P2P, a payment instruction is automatically sent to the Contracting Authority’s finance system to make payment to the supplier for the goods/services received. Electronic Invoices - Supplier submits an electronic invoice either directly to PECOS P2P/relevant system (cXML) and/or via the SG eInvoicing Solution, which can go again direct to PECOS P2P or a Contracting Authority’s finance system.
Power Factor Design Criteria Developer shall design the Large Generating Facility to maintain an effective power delivery at demonstrated maximum net capability at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all generators in the New York Control Area on a comparable basis. The Developer shall design and maintain the plant auxiliary systems to operate safely throughout the entire real and reactive power design range. The Connecting Transmission Owner shall not unreasonably restrict or condition the reactive power production or absorption of the Large Generating Facility in accordance with Good Utility Practice.
Over Allotment Option (a) For the purposes of covering any over-allotments in connection with the distribution and sale of the Closing Securities, the Representative is hereby granted an option (the “Over-Allotment Option”) to purchase, in the aggregate, up to _______ shares of Common Stock (the “Option Shares”) and Warrants to purchase up to ______ shares of Common Stock (the “Option Warrants” and, together with the Option Shares, the “Option Securities”) which may be purchased in any combination of Option Shares and/or Option Warrants at the Share Purchase Price and/or Warrant Purchase Price, respectively. (b) In connection with an exercise of the Over-Allotment Option, (a) the purchase price to be paid for the Option Shares is equal to the product of the Share Purchase Price multiplied by the number of Option Shares to be purchased, and (b) the purchase price to be paid for the Option Warrants is equal to the product of the Warrant Purchase Price multiplied by the number of Option Warrants to be purchased (the aggregate purchase price to be paid on an Option Closing Date, the “Option Closing Purchase Price”). (c) The Over-Allotment Option granted pursuant to this Section 2.2 may be exercised by the Representative as to all (at any time) or any part (from time to time) of the Option Securities within 45 days after the Execution Date. An Underwriter will not be under any obligation to purchase any Option Securities prior to the exercise of the Over-Allotment Option by the Representative. The Over-Allotment Option granted hereby may be exercised by the giving of oral notice to the Company from the Representative, which must be confirmed in writing by overnight mail or facsimile or other electronic transmission setting forth the number of Option Shares and/or Option Warrants to be purchased and the date and time for delivery of and payment for the Option Securities (each, an “Option Closing Date”), which will not be later than two (2) full Business Days after the date of the notice or such other time as shall be agreed upon by the Company and the Representative, at the offices of EGS or at such other place (including remotely by facsimile or other electronic transmission) as shall be agreed upon by the Company and the Representative. Each Option Closing Date will be as set forth in the notice. Upon exercise of the Over-Allotment Option, the Company will become obligated to convey to the Underwriters, and, subject to the terms and conditions set forth herein, the Underwriters will become obligated to purchase, the number of Option Shares and/or Option Warrants specified in such notice. The Representative may cancel the Over-Allotment Option at any time prior to the expiration of the Over-Allotment Option by written notice to the Company. On each Option Closing Date, if any, each Underwriter shall deliver or cause to be delivered to the Company, via wire transfer, immediately available funds equal to such Underwriter’s Option Closing Purchase Price and the Company shall deliver to, or as directed by, such Underwriter its respective Option Shares and the Company shall deliver the other items required pursuant to Section 2.3 deliverable at the Option Closing. Upon satisfaction of the covenants and conditions set forth in Sections 2.3 and 2.4, the Option Closing shall occur at the offices of EGS or such other location as the Company and Representative shall mutually agree.
Field Trips Orange COUNTY funds may not be used to support any overnight and/or out of Central Florida travel, unless approved by the COUNTY’S Manager of the CCC or designee in advance. The AGENCY must have on file for field trip(s) that each participant, adult or minor, must have a signed release of liability form releasing the COUNTY from any liability. If the participant is a minor, the release must be signed by a parent/guardian. Central Florida is defined as Orange, Osceola, Seminole, Brevard, Lake, Polk, and Volusia Counties.
Power Factor The Power Producer shall maintain the Power Factor as per the prevailing GERC regulations and as may be stipulated / specified by GETCO from time to time. The Power Producer shall provide suitable protection devices, so that the Electric Generators could be isolated automatically when grid supply fails. Connectivity criteria like short circuit level (for switchgear), neutral Grounding, fault clearance time, current unbalance (including negative and zero sequence currents), limit of harmonics etc. shall be as per Grid Code.