SERVICE REQUIRMENTS. 4.1 The Contracting QP shall place one (1) Order for each E-LAN Connection. For example, if the Contracting QP wishes to take up two (2) E-LAN Connections, the Contracting QP shall submit two (2) separate Orders. 4.2 When placing an Order for an E-LAN Connection, the Contracting QP shall be required to: (a) Specify one (1) E-LAN Service Port type and the address of the installation location, except that where any such installation location is an NBAP, the Contracting QP is required to provide Global Positioning System (GPS) co- ordinates and description of such installation location. The E-LAN Service Port may be new or then existing and if the latter, the Contracting QP shall be required to specify the Service Port ID in respect of such E-LAN Service Port. The E-LAN Service Port type is either Fast Ethernet (“FE Service Port”) or Gigabit Ethernet (“GE Service Port”). For FE Service Port(s), each E-LAN Connection will have a Symmetrical PIR of 100Mbps. For GE Service Port(s), each E-LAN Connection will have a Symmetrical PIR of 1Gbps. In the case of multiple E-LAN Connections sharing the same E-LAN Service Port, the number of Media Access Control (MAC) addresses that can be configured per E-LAN Connection is two (2). Additional MAC addresses may be configured per E-LAN Connection subject to the availability of Nucleus Connect’s Network resources. (b) Specify the following Network protocol options: (i) VLAN (IEEE 802.1q), VLAN(IEEEQ-in-Q) or without VLAN. In the case of multiple E-LAN Connections sharing the same E-LAN Service Port, the maximum number of VLANs that can be configured per E-LAN Service Port is sixteen (16); and
Appears in 3 contracts
Sources: Service Schedule, Service Schedule, Service Schedule
SERVICE REQUIRMENTS.
4.1 The Contracting QP shall place one (1) Order for each E-LAN Connection. For example, if the Contracting QP wishes to take up two (2) E-LAN Connections, the Contracting QP shall submit two (2) separate Orders.
4.2 When placing an Order for an E-LAN Connection, the Contracting QP shall be required to:
(a) Specify one (1) E-LAN Service Port type and the address of the installation location, except that where any such installation location is an NBAP, the Contracting QP is required to provide Global Positioning System (GPS) co- ordinates and description of such installation location. The E-LAN Service Port may be new or then existing and if the latter, the Contracting QP shall be required to specify the Service Port ID in respect of such E-LAN Service Port. The E-LAN Service Port type is either Fast Ethernet (“FE Service Port”) or Gigabit Ethernet (“GE Service Port”). For FE Service Port(s), each E-LAN Connection will have a Symmetrical PIR of 100Mbps. For GE Service Port(s), each E-LAN Connection will have a Symmetrical PIR of 1Gbps. In the case of multiple E-LAN Connections sharing the same E-LAN Service Port, the number of Media Access Control (MAC) addresses that can be configured per E-LAN Connection is two (2). Additional MAC addresses may be configured per E-LAN Connection subject to the availability of Nucleus Connect’s Network resources.
(b) Specify the following Network protocol options:
(i) VLAN (IEEE 802.1q), VLAN(IEEEQ-in-Q) or without VLAN. In the case of multiple E-LAN Connections sharing the same E-LAN Service Port, the maximum number of VLANs that can be configured per E-LAN Service Port is sixteen (16); and
Appears in 2 contracts
Sources: Service Schedule, Service Schedule