Storm Sewers. (a) The Developer shall, at no expense to the Town, except as hereinafter provided, construct and install all storm sewers to the 200 mm diameter PVC sanitary main, complete with manholes and other accessories both within and outside the development area which may, in the opinion of the Town, be required to serve the development area and that the servicing works shall include Parts 1, 2, 3, 4 Plan 59R-15974 and Parts 1, 2 and 3 Plan 59R- 15972 and the buildings to be erected thereon, in accordance with Town standards and approved drawings by the Director of Public Works and filed in the Town's offices prior to the issuance of a Building Permit. The design of such services shall be approved by the Director of Public Works prior to commencing construction and installation of the services. (b) If required by the Town, and prior to the execution of this Agreement by the Town, the Developer shall undertake review of the existing downstream storm sewer system to ensure the capacity of the system is sufficient for the increase in flows from the Development Agreement. In the event the downstream system is inadequate for the flow increase from this development, upgrading of those facilities will be the financial responsibility of the Developer and the Work required and/or necessary to upgrade such facilities shall be completed by the Developer as part of development of this Development Agreement to the complete satisfaction of the Director of Public Works. (c) The Developer shall, at no expense to the Town, construct a storm sewer system, including service laterals from the storm main to the property line and other appurtenances, to adequately service the Lands. All storm sewers, including upgrading of downstream facilities if deemed necessary by the Town, shall be constructed according to the approved Plans and specifications. Plans must be approved by the Director of Public Works, the Region of Niagara Public Works Department and the Ministry of the Environment and Climate Control, and the construction and materials used therein shall be in accordance with the Town’s most recent specifications therefore. (d) The location of the storm sewer laterals shall be illustrated on a detailed Site Servicing and Grading Plan drawing including calculations and restoration of affected road and boulevard surfaces. The Site Servicing and Grading Plan (e) Prior to Certificate of final completion, the storm sewer system must be flushed by high pressure flushing equipment and a digital copy of the CCTV Inspection shall be provided to the Town.
Appears in 2 contracts
Sources: Development Agreement, Development Agreement