Common use of Submission of Drawings Clause in Contracts

Submission of Drawings. A. Tenant shall submit for Landlord's review and written approval, complete architectural and engineering drawings, including but not limited to mechanical, electrical, plumbing, sprinkler and structural drawings which fully detail all aspects of the proposed Alterations as follows: - Four (4) complete sets of full-sized 1/8” scale drawings. - Complete set of Architectural and Engineering drawings submitted electronically utilizing AutoCAD format. - All revisions and final “As-Built” drawings are to be provided in AutoCAD format. - Electronic drawings should be sent to ▇▇▇▇▇▇▇▇@▇▇▇▇▇.▇▇▇. B. All drawings submitted for Landlord's review must be prepared, signed and sealed by Tenant's registered architect and professional engineer, licensed to conduct business in the State of New York. C. Tenant’s drawings must include details of connections to all Base Buildings systems and must be accompanied by a statement outlining the total electrical and mechanical loads. D. Landlord reserves the right to refer Tenant’s drawings to Landlord’s consulting engineers for review. All costs incurred by Landlord for any such review, approval and/or inspection of Tenant’s Alteration shall be reimbursed by Tenant. E. Tenant shall provide Landlord, for Landlord’s review and written approval, all revised, modified and/or additional drawings issued in the course of the Alteration, in the quantities and format outlined in (A.) above. F. Landlord’s review and approval of Tenant’s drawings is for consent purposes only and is not a review for compliance with any law, ordinance, code or insurance requirement, nor a review of the adequacy of Tenant’s design. No such approval or comments shall constitute a waiver of the obligation that the Alteration complies with all governmental laws, codes, rules, regulations, or the terms and conditions outlined in this Exhibit. G. Landlord’s approval or disapproval of the Alteration, or required revisions to and re-submission of Tenant’s drawings which incorporate Landlord’s comments shall in no way be construed or considered a delay caused by Landlord. H. Upon the completion of the Alteration, Tenant shall provide Landlord a complete set of final architectural and engineering “As-Built” drawings in the quantities and format outlined in (A.) above.

Appears in 1 contract

Sources: Lease Agreement (Lev Pharmaceuticals Inc)

Submission of Drawings. A. Tenant Tender drawings prepared by Employers are based on preliminary survey. Details and drawings given in Tender document is for indicative purpose only and successful bidder shall undertake confirmatory survey for accuracy and completeness of data. It is in scope of successful Bidder to undertake all Site surveys, Geotechnical investigations, carry out Designing and Drawings for Architectural, Civil, Structural, Electrical and Landscape work and submit the same to client for Landlord's review and written approval, complete architectural Prepare Good for Construction Drawings. The Contractor shall carry out the design and engineering drawingssubmit to the client, including but not limited to mechanical, electrical, plumbing, sprinkler and structural along with all the good for construction drawings which fully detail for all aspects the components of the proposed Alterations work as follows: - Four (4) complete sets of full-sized 1/8” scale drawingsper Employers requirement and submit the same to client for review and approval. - Complete set of Architectural The successful bidder shall have to prepare and Engineering drawings submitted electronically utilizing AutoCAD submit ‘As Built Drawings’ depicting the exact construction carried out on site, in soft and hard copy format. - All revisions Architectural, Civil, Structural and final “As-Built” drawings are to be provided in AutoCAD format. - Electronic drawings should be sent to ▇▇▇▇▇▇▇▇@▇▇▇▇▇.▇▇▇. B. All drawings submitted for Landlord's review must be prepared, signed Services Design and sealed by Tenant's registered architect and professional engineer, licensed to conduct business in the State of New York. C. Tenant’s drawings must include details of connections to all Base Buildings systems and must be accompanied by a statement outlining the total electrical and mechanical loads. D. Landlord reserves the right to refer Tenant’s drawings to Landlord’s consulting engineers for review. All costs incurred by Landlord for any such review, approval and/or inspection of Tenant’s Alteration Drawings shall be reimbursed by Tenant. E. Tenant shall provide Landlord, submitted to RSCL for Landlord’s review and written approval, all revised, modified and/or additional drawings issued in the course of the Alteration, in the quantities and format outlined in (A.) above. F. Landlord’s review and approval within 8 days from commencement of Tenant’s Work. Drawings will be submitted by the agency, which will be got approved from the institutions stated in the tender documents. It has to be ensured by the agency that the drawings are got approved from the institution referred above within Two weeks from the date of its submission. All service plans should be got approved from the concern Authority/department within 8 days from the stipulated date of Commencement. It is for consent purposes only and is not a review for compliance with any law, ordinance, code or insurance requirement, nor a review entirely the responsibility of the adequacy contractor to get the above designs approved and finalized within aforesaid period. Any delay on this account will attract compensation. The contractor(s) shall supply 5 copies of Tenant’s design. No such approval or comments shall constitute a waiver / laminated approved structural drawings/architectural drawings/ services drawings to the Engineer-in-charge for the use of the obligation that RSCL after having approved from the Alteration complies with competent authority within 7 days from the receipt of approval. In addition to above sets of drawings, contractor shall keep necessary sets of drawings required at site for its execution as directed by the Engineer-in-charge. The successful Contractor shall have to prepare and submit ‘As Built Drawings’ depicting the exact construction carried out on site, in soft and hard copy format & get the same approved from Employer/PMC. Within 8 days from the Commencement Date the Contractor shall start submitting drawings, construction documents, etc., for review and approval by the Employer’s Representative. Contractor shall prepare detailed Programme in MS project software and get it approved from EIC/PMC. The Contractor shall submit all governmental laws, codes, rules, regulations, or the terms and conditions outlined in this ExhibitDrawings as per Schedule approved by the Employer. G. Landlord’s approval or disapproval of the Alteration, or required revisions to and re-submission of Tenant’s drawings which incorporate Landlord’s comments shall in no way be construed or considered a delay caused by Landlord. H. Upon the completion of the Alteration, Tenant shall provide Landlord a complete set of final architectural and engineering “As-Built” drawings in the quantities and format outlined in (A.) above.

Appears in 1 contract

Sources: General Conditions of Contract