Subrecipient Response Clause Samples

The Subrecipient Response clause outlines the obligations and procedures for a subrecipient to reply to requests, directives, or communications from the primary recipient or grantor. Typically, this clause specifies the timeframe within which the subrecipient must respond, the format or method of response, and the types of information or documentation that must be provided. For example, it may require the subrecipient to submit progress reports, financial statements, or compliance certifications within a set number of days after receiving a request. The core function of this clause is to ensure timely and effective communication between parties, thereby promoting accountability and smooth administration of the agreement.
Subrecipient Response. The Subrecipient shall have 30 days from the receipt of a financial or programmatic monitoring visit letter to address any findings or concerns.

Related to Subrecipient Response

  • Incident Response Operator shall have a written incident response plan that reflects best practices and is consistent with industry standards and federal and state law for responding to a data breach, breach of security, privacy incident or unauthorized acquisition or use of any portion of Data, including PII, and agrees to provide LEA, upon request, an executive summary of the written incident response plan.

  • Company’s Response Upon receipt by the Company of a copy of a Purchase Notice, the Company shall as soon as practicable, but in no event later than one (1) Trading Day after receipt of such Purchase Notice, send via facsimile (or otherwise deliver), a confirmation of receipt of such Purchase Notice in the form attached hereto as Exhibit B (a "Company Confirmation of Purchase Notice") to (1) the Buyer and (2) along with a copy of the Purchase Notice, the Company's designated transfer agent (the "Transfer Agent"), which confirmation shall constitute an irrevocable instruction to the Transfer Agent to process such Purchase Notice in accordance with the terms herein. Upon receipt by the Transfer Agent of a copy of the executed Purchase Notice and a copy of the applicable Company Confirmation of Purchase Notice, the Transfer Agent shall, on the first (1st) Trading Day following the date of receipt of the Company Confirmation of Purchase Notice, (A) provided the Transfer Agent is participating in The Depository Trust Company's ("The DTC") Fast Automated Securities Transfer Program, credit such aggregate number of shares of Common Stock to which the Buyer shall be entitled to the Buyer's or its designee's balance account with The DTC through its Deposit Withdrawal At Custodian ("DWAC") system, or (B) if the Transfer Agent is not participating in The DTC Fast Automated Securities Transfer Program and DWAC system, issue and surrender to a common carrier for overnight delivery to the address as specified in the Purchase Notice, a certificate, registered in the name of the Buyer or its designee, for the number of shares of Common Stock to which the Buyer shall be entitled.

  • Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.

  • Client Responsibility For clarity, the parties agree that in reviewing the documents referred to in clause (b) above, Patheon’s role will be limited to verifying the accuracy of the description of the work undertaken or to be undertaken by Patheon. Subject to the foregoing, Patheon will not assume any responsibility for the accuracy of any application for receipt of an approval by a Regulatory Authority. The Client is solely responsible for the preparation and filing of the application for approval by the Regulatory Authority and any relevant costs will be borne by the Client.

  • Timely and Sustained Response Interconnection Customer shall ensure that the Small Generating Facility’s real power response to sustained frequency deviations outside of the deadband setting is automatically provided and shall begin immediately after frequency deviates outside of the deadband, and to the extent the Small Generating Facility has operating capability in the direction needed to correct the frequency deviation. Interconnection Customer shall not block or otherwise inhibit the ability of the governor or equivalent controls to respond and shall ensure that the response is not inhibited, except under certain operational constraints including, but not limited to, ambient temperature limitations, physical energy limitations, outages of mechanical equipment, or regulatory requirements. The Small Generating Facility shall sustain the real power response at least until system frequency returns to a value within the deadband setting of the governor or equivalent controls. An Applicable Reliability Standard with equivalent or more stringent requirements shall supersede the above requirements.