Water Level Gauges Sample Clauses

Water Level Gauges. The Contractor shall install and maintain suitable automatic water level gauge at an approved location close to the Works. This gauge shall be placed and calibrated at least 30 days before com- mencement of the construction of the Works. The water level gauge should be connected to an established bench mark (30 cm x 30 cm RCC pillar with 30 cm height above ground level) to be erected in the vicinity (within 5 km of the dredging site) by the Contractor, which should be having Reduced Level (RL) with respect to Mean Sea Level (MSL) and Geo Co-ordinates. The RL should be established by transfer of level from a known GTS bench mark by proper levelling. The contractor has to connect the Water level gauge with the Bench mark and establish the Chart datum value on the gauge by proper levelling. Cost of construction of Bench mark, Levelling, Erection of Automatic Water Level gauge and collection of Gauge Readings are to be borne by the Contractor. During Echo sounding, water levels shall be recorded continuously.
Water Level Gauges. The Contractor shall install and maintain suitable automatic water level gauge at an approved location close to the Works. This gauge shall be placed and calibrated at least 30 days before commencement of the construction of the Works. The water level gauge should be connected to an established bench mark (30 cm x 30 cm RCC pillar with 30 cm height above ground level) to be erected in the vicinity (within 5 km of the dredging site) by the Contractor, which should be having Reduced Level (RL) with respect to Mean Sea Level (MSL) and Geo Co-ordinates. The RL should be established by transfer of level from a known GTS bench mark by proper levelling. The Chart Datum values ▇.▇.▇▇ MSL for some locations are available in the DPR. The contractor has to connect the Water level gauge with the Bench mark and establish the Chart datum value on the gauge by proper levelling. Cost of construction of Bench mark, Levelling, Erection of Automatic Water Level gauge and collection of Gauge Readings are to be borne by the Contractor. During Echo sounding, water levels shall be recorded continuously.
Water Level Gauges. Water level gauges are to be erected at every 10 km interval along the canal/river and also at upstream and downstream of Locks, Sluice gates, Barrages, Dams etc. simultaneously. Readings are to be taken at 1 hr interval for 12 hours (6 AM to 6 PM) or for the entire period of survey. The gauges are to be connected to a nearest Bench Mark by leveling and its datum value shall be established ▇.▇.▇▇ MSL & CD. Water level gauges are to be installed temporarily during the survey period.
Water Level Gauges. Water level gauges are to be erected at every 10 km interval along the canal/river and also at upstream and downstream of Locks, Sluice gates, Barrages, Dams etc. simultaneously. Readings are to be taken at 1 hr interval for 12 hours (6 AM to 6 PM) or for the entire period of survey. The gauges are to be connected to a nearest Bench Mark by leveling and its datum value shall be established ▇.▇.▇▇ MSL & CD. Water level gauges are to be installed temporarily during the survey period.

Related to Water Level Gauges

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • Usage Measurement Usage measurement for calls shall begin when answer supervision or equivalent Signaling System 7 (SS7) message is received from the terminating office and shall end at the time of call disconnect by the calling or called subscriber, whichever occurs first.

  • Staffing Levels To the extent legislative appropriations and PIN authorizations allow, safe staffing levels will be maintained in all institutions where employees have patient, client, inmate or student care responsibilities. In July of each year, the Secretary or Deputy Secretary of each agency will, upon request, meet with the Union, to hear the employees’ views regarding staffing levels. In August of each year, the Secretary or Deputy Secretary of Budget and Management will, upon request, meet with the Union to hear the employees’ views regarding the Governor’s budget request.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point ▇▇▇▇▇▇. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • Number Resources, Rate Center Areas and Routing Points 13.1 Nothing in this Agreement shall be construed to limit or otherwise adversely affect in any manner either Party’s right to employ or to request and be assigned any Central Office Codes (“NXX”) pursuant to the Central Office Code Assignment Guidelines and any relevant FCC or Commission orders, as may be amended from time to time, or to establish, by Tariff or otherwise, Rate Center Areas and Routing Points corresponding to such NXX codes. 13.2 It shall be the responsibility of each Party to program and update its own switches and network systems pursuant to information provided on ASRs as well as the LERG in order to recognize and route traffic to the other Party’s assigned NXX codes. Except as expressly set forth in this Agreement, neither Party shall impose any fees or charges whatsoever on the other Party for such activities. 13.3 Unless otherwise required by Commission order, the Rate Center Areas will be the same for each Party. During the term of this Agreement, Onvoy shall adopt the Rate Center Area and Rate Center Points that the Commission has approved for Frontier within the LATA and Tandem serving area. Onvoy shall assign whole NPA-NXX codes to each Rate Center Area unless otherwise ordered by the FCC, the Commission or another governmental entity of appropriate jurisdiction, or the LEC industry adopts alternative methods of utilizing NXXs. 13.4 Onvoy will also designate a Routing Point for each assigned NXX code. Onvoy shall designate one location for each Rate Center Area in which the Onvoy has established NXX code(s) as the Routing Point for the NPA-NXXs associated with that Rate Center Area, and such Routing Point shall be within the same LATA as the Rate Center Area but not necessarily within the Rate Center Area itself. Unless specified otherwise, calls to subsequent NXXs of Onvoy will be routed in the same manner as calls to ▇▇▇▇▇’s initial NXXs. 13.5 Notwithstanding anything to the contrary contained herein, nothing in this Agreement is intended, and nothing in this Agreement shall be construed, to in any way constrain Onvoy’s choices regarding the size of the local calling area(s) that Onvoy may establish for its Customers, which local calling areas may be larger than, smaller than, or identical to Frontier’s local calling areas.