Access Following Construction Clause Samples

The "Access Following Construction" clause defines the rights and procedures for parties to access a property after construction work has been completed. Typically, this clause outlines who may enter the premises, under what circumstances, and for what purposes—such as inspections, maintenance, or warranty repairs. For example, it may allow the contractor to return to the site to address defects or for the owner to inspect completed work. Its core practical function is to ensure that necessary post-construction activities can be carried out efficiently while protecting the interests and privacy of the property owner.
Access Following Construction. After the occurrence of the Actual Completion Date [a Phase Actual Completion Date] the Authority shall grant to DBFM Co and DBFM Co Parties, or procure that DBFM Co and DBFM Co Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:
Access Following Construction. After the occurrence of the Actual Completion Date [and the Actual Post Completion Works Date in respect of the Post Completion Works Areas] the Authority shall grant to D&B Co and D&B Co Parties, or procure that D&B Co and D&B Co Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:
Access Following Construction. After the occurrence of the Actual Completion Date [for a Facility] [and the Actual Post Completion Works Date in respect of the [relevant] Post Completion Works Areas of [a]/[the] Facility only] the Authority shall grant to Project Co and Project Co Parties, or procure that Project Co and Project Co Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:
Access Following Construction. After the occurrence of the issue of the Permit to Use [a Phase Actual Completion Date] the Authority shall grant to Project Co and Project Co Parties, or procure that Project Co and Project Co Parties are granted, access to the Site subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:
Access Following Construction. After the occurrence of the Actual Completion Date the Authority shall grant to hubco and hubco Parties or procure that hubco and hubco Parties are granted access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:- carrying out ▇▇▇▇▇'s Post Completion Commissioning during the period permitted therefor and subject to the terms of the Final Commissioning Programme; remedying of Defects pursuant to Clause 17 (Defects) during the Defects Liability Period and the period of [ ] months specified in Clause 17.2; and the carrying out of Snagging Matters during the period specified therefor in Clause 16.13.
Access Following Construction. After the occurrence of the Actual Completion Date [a Phase Actual Completion Date] the Authority shall grant to Sub-hubco and Sub-hubco Parties, or procure that Sub-hubco and Sub-hubco Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of:
Access Following Construction. After the occurrence of the Actual Completion Date [a Phase Actual Completion Date] the Authority shall grant to Project Co and Project Co Parties, or procure that Project Co and Project Co Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of: carrying out the Project Operations (other than those Project Operations for which Project Co is granted rights pursuant to Clause 9.1 (Access During Construction)); remedying Defects and carrying out Snagging Matters [relating to that Phase]; and exercising the Ancillary Rights. Such rights shall terminate on the Expiry Date or (if earlier) the Termination Date.
Access Following Construction. After the occurrence of the Actual Completion Date [a Phase Actual Completion Date] the Authority shall grant to Sub-hubco and Sub-hubco Parties, or procure that Sub-hubco and Sub-hubco Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of: carrying out the Project Operations (other than those Project Operations for which Sub-hubco is granted rights pursuant to Clause 9.1 (Access During Construction)); remedying Defects and carrying out Snagging Matters [relating to that Phase]; and exercising the Ancillary Rights. Such rights shall terminate on the Expiry Date or (if earlier) the Termination Date.
Access Following Construction. After the occurrence of the Actual Completion Date [a Phase Actual Completion Date] the Authority shall grant to DBFM Co and DBFM Co Parties, or procure that DBFM Co and DBFM Co Parties are granted, access to the Facilities subject only to the Reserved Rights, the Title Conditions and the provisions of this Agreement and solely for the purposes of: carrying out the Project Operations (other than those Project Operations for which DBFM Co is granted rights pursuant to Clause 9.1 (Access During Construction)); remedying Defects and carrying out Snagging Matters [relating to that Phase] or exercising its rights under Clause 23.15; and exercising the Ancillary Rights. Such rights shall terminate on the Expiry Date or (if earlier) the Termination Date.

Related to Access Following Construction

  • Law; Construction This Agreement and any claim, counterclaim or dispute of any kind or nature whatsoever arising out of or in any way relating to this Agreement (“Claim”), directly or indirectly, shall be governed by, and construed in accordance with, the internal laws of the State of New York.

  • General Construction 20.2.1. Binding Nature.............................................. 20.2.2. Entire Agreement............................................ 20.2.3. Governing Law............................................... 20.2.4. Indulgences Not Waivers..................................... 20.2.5. Titles Not to Affect Interpretation......................... 20.2.6.

  • DAF Construction The DAF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Developer and Connecting Transmission Owner agree on another mutually acceptable deadline, the Developer shall deliver to the Connecting Transmission Owner and NYISO “as- built” drawings, information and documents for the DAF, such as: a one-line diagram, a site plan showing the Large Generating Facility and the DAF, plan and elevation drawings showing the layout of the DAF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Developer’s step-up transformers, the facilities connecting the Large Generating Facility to the step-up transformers and the DAF, and the impedances (determined by factory tests) for the associated step-up transformers and the Large Generating Facility. The Developer shall provide to, and coordinate with, Connecting Transmission Owner and NYISO with respect to proposed specifications for the excitation system, automatic voltage regulator, Large Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.

  • ICIF Construction The ICIF shall be designed and constructed in accordance with Good Utility Practice. Within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Parties agree on another mutually acceptable deadline, Interconnection Customer shall deliver to Transmission Provider and Transmission Owner “as-built” drawings, information and documents for the ICIF, such as: a one-line diagram, a site plan showing the Generating Facility and the ICIF, plan and elevation drawings showing the layout of the ICIF, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer’s step-up transformers, the facilities connecting the Generating Facility to the step-up transformers and the ICIF, and the impedances (determined by factory tests) for the associated step-up transformers and the Generating Facility. Interconnection Customer shall provide Transmission Provider and Transmission Owner with Interconnection Customer’s specifications for the excitation system, automatic voltage regulator, Generating Facility control and protection settings, transformer tap settings, and communications, if applicable.

  • During Construction Upon request of the Owner the Contractor shall submit written proposals for unit prices to be applied in the event Change Order Work is authorized by the Owner to be performed under Case (b).