Building Standard Improvements. For the purposes of establishing a standard quality and quantity for materials and finishes comprising the Leasehold Improvements, Landlord, in Landlord's sole discretion, has established the following "Building Standard" items (also referred to as "Building Standards"): a) Building Standard Shell Improvements: (i) Heating, Ventilation and Air Conditioning: Installed as per Landlord's engineering design of the Building. (ii) Electrical: Main power and lighting distribution system per applicable building code. (iii) Fire Protection System: Automatic sprinkler system, to the extent required per applicable building code. b) Building Standard Allowance Items (“Allowance Items”)(to be provided using Building Standard materials): (i) Interior Partitions: One layer of 1/2" drywall mounted on each side of 3-5/8" metal studs extending 2" above the finished ceiling height. Taped, finished and painted (two coats) partitioning to be provided with 4" high vinyl baseboard, 1 lineal foot per 12 square feet. (ii) Demising Partitions: Constructed as needed from floor to floor, taped, finished and painted (two (2) coats) consisting of one layer of 5/8" fire-rated drywall mounted on each side of 3 -5/8" metal studs, with 3 - 1/2" layer of insulation. (iii) Entry Doors; Self-closing 3'0" x 9'0" solid core wood doors with lock set. One door per 2,500 square feet, with a maximum of two doors per suite.
Appears in 1 contract
Sources: Lease (Ominto, Inc.)
Building Standard Improvements. For the purposes of establishing a standard quality and quantity for materials and finishes comprising the Leasehold Improvements, Landlord, in Landlord's ’s sole discretion, has established the following "“Building Standard" ” items (also referred to as "“Building Standards"”):
a) Building Standard Shell Improvements:
(i) Heating, Ventilation and Air Conditioning: Installed as per Landlord's ’s engineering design of the Building.
(ii) Electrical: Main power and lighting distribution system per applicable building code.
(iii) Fire Protection System: Automatic sprinkler system, to the extent required per applicable building code.
b) Building Standard Allowance Items (“Allowance Items”)(to to be provided using Building Standard materials):
(i) Interior Partitions: One layer of 1/2" ” drywall mounted on each side of 3-3- 5/8" ” metal studs extending 2" ” above the finished ceiling height. Taped, finished and painted (two coats) partitioning to be provided with 4" ” high vinyl baseboard, 1 lineal foot per 12 square feet.
(ii) Demising Partitions: Constructed as needed from floor to floor, taped, finished and painted (two (2) coats) consisting of one layer of 5/8" ” fire-rated drywall mounted on each side of 3 -5/8" - 5/8” metal studs, with 3 - 3- 1/2" ” layer of insulation.
(iii) Entry Doors; Self-closing 3'0" 3’0” x 9'0" 9’0” solid core wood doors with lock set. One door per 2,500 square feet, with a maximum of two doors per suite.