CLEC Methods of Interconnection Clause Samples

CLEC Methods of Interconnection. In addition to Collocation in SBC- AMERITECH’s Switch Center or Fiber Meet as currently provided for in the Agreement, CLEC may interconnect with SBC-AMERITECH for purposes of delivering Local Traffic and IntraLATA Toll Traffic originating in CLEC's network for termination on SBC- AMERITECH’s network by using the method of Interconnection described below: 3.3.1 Under this method of Interconnection, CLEC will transport Local Traffic and IntraLATA Toll Traffic to SBC-AMERITECH’s Tandem Offices by using trunks (i.e., DS1's) on existing DS3 access facilities between CLEC's Switch Center POIs and the SBC-AMERITECH Tandem Office POI. Such facilities may be provided by SBC- AMERITECH, CLEC, other vendors used by CLEC or SBC-AMERITECH, or a combination thereof. 3.3.2 If additional capacity is needed for Interconnection under this method, CLEC will provision such facilities: (i) from SBC-AMERITECH under its access tariff, (ii) from SBC-AMERITECH under Article IX of the Agreement, (iii) from CLEC's own facility inventory, or (iv) from an alternative access vendor. 3.3.3 CLEC may interconnect with SBC-AMERITECH at a DS1 bandwidth. SBC-AMERITECH may allow Interconnection at other bandwidths where technically feasible and mutually agreeable at termination charges to be agreed upon by the Parties. SBC-AMERITECH will provide any multiplexing required for DS1 facilities or trunking at their end and CLEC will provide any DS1 multiplexing required for facilities or trunking at their end.
CLEC Methods of Interconnection. In addition to Collocation in SBC ILLINOIS' Switch Center or Fiber Meet as currently provided for in the Agreement, CLEC may interconnect with SBC ILLINOIS for purposes of delivering Local Traffic and IntraLATA Toll Traffic originating in CLEC's network for termination on SBC ILLINOIS' network by using the methods of Interconnection described below: 3.3.1 CLEC will transport Local Traffic and IntraLATA Toll Traffic to SBC ILLINOIS's Tandem Offices by using trunks (i.e., DS1's) on existing DS3 access facilities between CLEC's Switch Center POIs and the SBC ILLINOIS Tandem Office POI. Such facilities may be provided by SBC ILLINOIS, CLEC, other vendors used by CLEC or SBC ILLINOIS, or a combination thereof. 3.3.2 CLEC may obtain facility capacity for network interconnection trunking: (i) from SBC ILLINOIS under its access tariff, (ii) from SBC ILLINOIS under Article 9 of the Agreement, (iii) from CLEC's own facility inventory, or (iv) from an alternative access vendor.
CLEC Methods of Interconnection. In addition to Collocation in SBC- AMERITECH’s Switch Center or Fiber Meet as currently provided for in the Agreement, CLEC may interconnect with SBC-AMERITECH for purposes of delivering Local Traffic 3.3.1 Under this method of Interconnection, CLEC will transport Local Traffic and IntraLATA Toll Traffic to SBC-AMERITECH’s Tandem Offices by using trunks (i.e., DS1's) on existing DS3 access facilities between CLEC's Switch Center POIs and the SBC-AMERITECH Tandem Office POI. Such facilities may be provided by SBC- AMERITECH, CLEC, other vendors used by CLEC or SBC-AMERITECH, or a combination thereof. 3.3.2 If additional capacity is needed for Interconnection under this method, CLEC will provision such facilities: (i) from SBC-AMERITECH under its access tariff, (ii) from SBC-AMERITECH under Article IX of the Agreement, (iii) from CLEC's own facility inventory, or (iv) from an alternative access vendor. 3.3.3 CLEC may interconnect with SBC-AMERITECH at a DS1 bandwidth. SBC-AMERITECH may allow Interconnection at other bandwidths where technically feasible and mutually agreeable at termination charges to be agreed upon by the Parties. SBC-AMERITECH will provide any multiplexing required for DS1 facilities or trunking at their end and CLEC will provide any DS1 multiplexing required for facilities or trunking at their end.
CLEC Methods of Interconnection. In addition to Collocation in AT&T 4- STATE's Switch Center or Fiber Meet as currently provided for in the Agreement, CLEC may interconnect with AT&T 4-STATE for purposes of delivering Local Traffic and IntraLATA Toll Traffic originating in CLEC's network for termination on AT&T 4-STATE's network by using the methods of Interconnection described below: 3.3.1 CLEC will transport Local Traffic and IntraLATA Toll Traffic to AT&T 4- STATE's Tandem Offices by using trunks (i.e., DS1's) on existing DS3 access facilities between CLEC's Switch Center POIs and the AT&T 4-STATE Tandem Office POI. Such facilities may be provided by AT&T 4-STATE, CLEC, other vendors used by CLEC or AT&T 4-STATE, or a combination thereof. 3.3.2 CLEC may obtain facility capacity for network interconnection trunking: (i) from AT&T 4-STATE under its access tariff, (ii) from AT&T 4-STATE under Article 9 of the Agreement, (iii) from CLEC's own facility inventory, or (iv) from an alternative access vendor.

Related to CLEC Methods of Interconnection

  • Methods of Interconnection The Parties will negotiate the facilities arrangement used to interconnect their respective networks. CLEC shall establish at least one (1) physical Point of Interconnection in CenturyLink territory in each LATA CLEC has local End User Customers. CLEC represents and warrants that it is serving End User Customers physically located within each local calling area for which it wishes to exchange traffic within CenturyLink territory. The Parties shall establish, through negotiations, at least one (1) of the following Interconnection arrangements, at any Technically Feasible point: (1) a DS1 or DS3 CenturyLink-provided facility; (2) Collocation; (3) negotiated Mid-Span Meet POI facilities; or (4) other Technically Feasible methods of Interconnection via the Bona Fide Request (BFR) process unless a particular arrangement has been previously provided to a third party, or is offered by CenturyLink as a product. 7.1.2.1 CenturyLink-provided Facility. Interconnection may be accomplished through the provision of a DS1 or DS3 Entrance Facility of CLEC's determination. An Entrance Facility extends from the CenturyLink Serving Wire Center to CLEC's Switch location or any Technically Feasible POI chosen by CLEC. CenturyLink-provided Entrance Facilities may not extend beyond the area served by the CenturyLink Serving Wire Center. The rates for CenturyLink-provided Entrance Facilities are provided in Exhibit A. CenturyLink's private line transport service is available as an alternative to CenturyLink-provided Entrance Facilities, when CLEC uses such private line transport service for multiple services. Entrance Facilities may not be used for Interconnection with Unbundled Network Elements. 7.1.2.2 Collocation. Interconnection may be accomplished through the Collocation arrangements offered by CenturyLink. The terms and conditions under which Collocation will be available are described in Section 8 of this Agreement. 7.1.2.2.1 Expanded Interconnection Channel Termination (EICT) provides the communication path that actually connects the physical space or in the case of virtual collocation, the designated equipment to CenturyLink's direct trunked transport and must be ordered to provision LIS to a collocation. 7.1.2.3 Mid-Span Meet POI. A Mid-Span Meet POI is a negotiated Point of Interface, limited to the Interconnection of facilities between the CenturyLink Serving Wire Center location and the location of the CLEC switch or other equipment located within the area served by the CenturyLink Serving Wire Center. The actual physical Point of Interface and facilities used will be subject to negotiations between the Parties. Each Party will be responsible for its portion of the build to the Mid-Span Meet POI. The Mid-Span Meet POI will be used exclusively as an Interconnection facility and cannot be used for other purposes such as Unbundled Network Elements or Access Services.

  • Network Interconnection Methods 3.1 The Interconnection provided herein may not be used solely for the purpose of originating a Party’s own interexchange traffic.

  • Points of Interconnection and Trunk Types 2.1 Point(s) of Interconnection. 2.1.1 Each Party, at its own expense, shall provide transport facilities to the technically feasible Point(s) of Interconnection on Verizon’s network in a LATA selected by PNG.