Compressors Sample Clauses

POPULAR SAMPLE Copied 1 times
Compressors. On compressor houses, manifold compressors or large single unit compressors (750 CFM or more) in the same location: one (1)
Compressors. This Section 07.06.00 shall not apply to the required ▇▇▇▇▇▇▇ on Compressor Houses.
Compressors. Lessor shall provide use of compressors throughout the Leased Premises at 100 PSI. The line from the compressors shall be extended to the production area as directed by Lessee.
Compressors. Since they can create can create a strong visual contrast and create auditory distractions, compressors will not be approved within two miles of the base of the Pumpkin Buttes.
Compressors. When the number of Compressors (excluding compressor house or plant) of the 150 C.F.M. type, gasoline or diesel driven exceed nine
Compressors. Single stage, heavy duty, air-cooled, oil-less air compressors. The air compressors shall be direct driven with 1,725 rpm, 460 volt, 3 phase, 5 hp motor to provide 30 acfm at 100 psi pressure. Motor shall be TEFC high efficient severe duty type in accordance with Section 11060.
Compressors. In no event shall any autoclaves, cage washers, fume hoods, laminar flow hoods or bio-safety cabinets purchased by Landlord or purchased using the TI Allowance or any additional tenant improvement allowance provided to Tenant by Landlord be included as Tenant’s Personal Property.
Compressors. All compressors shall be an oil free design. The compressor shall be capable of operating continuously at the maximum delivery pressure (5000 psig) under environmental conditions specified herein without having to stop for cool-down. The lubricants used shall be of an approved type listed in NAVSEA Technical manual S9086-H7-STM-010/CH-262.
Compressors. The compressors for the open loop heat pump can be seen in Figure 35 and are turbo compressors of the model EA42 with a custom dedicated impeller design for stage 1 and stage 2. The gearbox is cooled internally and the cooling water from the DC motor can be used to cool the gearbox. This is a significant improvement from the former EC38 units which required external oil cooling. Further improvement includes that the inlet and outlet connections from the compressor to the system can be adjusted so that standard industry piping and screw connections can be used. Figure 36 shows the connection pipe work of the EA42 and EC38 compressor, respectively.
Compressors. M▇▇▇▇▇▇▇ shall purchase the Compressors from TOGA for U. S. Two Hundred Thirty-three Thousand Eight Hundred Forty and no/100ths Dollars ($233,840. 00) at a point of delivery in Australia designated by TOGA, on or before September 30, 2002. M▇▇▇▇▇▇▇ shall make all arrangements, and pay all costs, duties, expenses and taxes applicable to the Compressors from the point of delivery. TOGA will provide M▇▇▇▇▇▇▇ an M▇▇▇▇▇▇▇ Drilling Contractors Pty Ltd. Page 4 October 7, 2002 opportunity to inspect the Compressors before the sale date, and M▇▇▇▇▇▇▇ shall accept the Compressors from TOGA “AS IS, WHERE IS AND SUBJECT TO ALL FAULTS”, AND WITHOUT ANY WARRANTIES (WHETHER EXPRESSED, IMPLIED OR STATUTORY) INCLUDING, WITHOUT LIMITATION, CONDITION, QUANTITY, QUALITY, FITNESS FOR A PARTICULAR PURPOSE, CONFORMITY TO THE MODELS OR SAMPLES OF MATERIALS, MERCHANTABILITY, FITNESS FOR ANY PURPOSE OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHTS. To the extent enforceable under applicable laws, TOGA will convey the Compressors to M▇▇▇▇▇▇▇ with full subrogation and substitution of M▇▇▇▇▇▇▇ to all applicable covenants and warranties including, without limitation, contractors’, manufacturers’ and suppliers’ warranties, which have heretofore been made by any third party contractor, manufacturer or supplier with respect to the Compressors.