CONTROL CABLES. 5.3.1 The Producer shall Maintain all control cables necessary for the Company's control, protection and metering purposes, up to the first termination point in the Company equipment. (As a note of clarification, the Producer is responsible for all control cables that run between the power plant and the substation regardless of whether the Company and/or the Producer uses the cables. If trouble occurs, the Party who uses the cable shall be responsible to trouble shoot the line to determine the cause of the problem.)
CONTROL CABLES. 5.3.1 The Producer shall Maintain all control cables between the main plant building and the substation necessary for the Company's control, protection and metering purposes, between the Producer's Purchased Assets and the Company's substation equipment, up to the first terminal point in the Company equipment. (As a note of clarification, the Producer is responsible for all control cables that run between the power plant and the substation regardless of whether the Company and/or the Producer use the cables. If trouble occurs, the Party who uses the cable shall be responsible to trouble shoot the line to determine the cause of the problem.)
CONTROL CABLES. The cables for connection of the control unit, distribution box, flow meter sensor, flow meter display units, pressure transducers and feedback sensor shall be 100% electrically shielded molded male by female cordsets. The cordsets shall have the ability to connect together and total length shall not exceed 40 feet (12 meters). The connections shall be keyed to prevent misconnection and improper system operation. Shielding shall be provided by an aluminized Mylar shield within the PVC outer jacket. A drain wire shall be tied to one of the pins on each end of the cable. No externally attached ferrite beads shall be installed for the purpose of electrical shielding. Coupling nuts on the cordset ends shall be constructed of nickel coated brass. When properly connected the connections shall be sealed to NEMA 4X or equal. A low tank level switch shall be installed in the foam concentrate tank. The low tank level sensor shall be connected to the foam proportioning system to provide protection against dry running of the foam pump. The low tank level sensor shall be mounted on the side of the foam concentrate tank. The low tank level sensor and electrical connections shall be sealed to prevent infusion of foam concentrate into the wiring and possible short circuit of the tank level sensor.
CONTROL CABLES. 1 Type LVT: soft annealed copper conductors, sized as indicated, with thermoplastic insulation, outer covering of thermoplastic jacket, and armour of closely wound aluminum wire. Part 3‌
CONTROL CABLES. 5.3.1 The Producer shall Maintain all control cables within the main plant building necessary for the Company's control, protection and metering purposes, between the Producer's Purchased Assets and the Company's equipment, up to the first terminal point in the Company equipment.
CONTROL CABLES. Control Cables or Control Cabling shall mean any cables or cabling used for control or instrumentation purposes. Control Cables shall have tinned copper conductors with PVC insulation rated for 600 V and PVC overall jacket unless otherwise specified. The use of copper sheathed cables will not be permitted.

Related to CONTROL CABLES

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.2.1 Local circuit switching capability is defined as all line-side and trunk-side facilities, plus the features, functions, and capabilities of the switch. The features, functions, and capabilities of the switch shall include the basic switching function of connecting lines to lines, lines to trunks, trunks to lines, and trunks to trunks. Local circuit switching includes all vertical features that the switch is capable of providing, including custom calling, custom local area signalling service features, and Centrex, as well as any technically feasible customized routing functions. 4.2.2 Notwithstanding BellSouth’s general duty to unbundle local circuit switching, BellSouth shall not be required to unbundle local circuit switching for ▇▇▇▇ when ▇▇▇▇: (1) serves an End User with four (4) or more voice-grade (DS0) equivalents or lines served by BellSouth in Zone 1 of one of the following MSAs: Atlanta, GA;

  • Input Control The possibility to subsequently verify and determine whether, and by whom, personal data was entered into, changed or removed from data processing systems must be ensured. • Definition of entry authorisation • Logging of logins

  • Access Control Supplier will maintain an appropriate access control policy that is designed to restrict access to Accenture Data and Supplier assets to authorized Personnel. Supplier will require that all accounts have complex passwords that contain letters, numbers, and special characters, be changed at least every 90 days, and have a minimum length of 8 characters.

  • Weed Control The tenant shall control all noxious weeds on the subject lands and maintain any summerfallow in a reasonably weed free condition.

  • System Access Control Data processing systems used to provide the Cloud Service must be prevented from being used without authorization.