Controller, CTSS Sample Clauses

Controller, CTSS. The supplying of materials, equipment, and software, configuration of controllers and communications equipment, and completing all work described in this section to install a properly functioning and operating CTSS, as well as testing, verification, and validation of the system, including on-site training is paid under CONTROLLER MODIFICATIONS, TYPE CTSS pay item.
Controller, CTSS. Prior to controller equipment procurement, perform a detailed inspection of the existing cabinet wiring and equipment configurations to assist in the switch over to the new equipment and the re-connection of appropriate wiring. Submit an assessment report to the RE for approval detailing the wiring with photos as well as assurances the new equipment can be installed on the existing cabinet. Bring any concerns with the new installation to the attention on the RE immediately upon discovery. Ensure the Controller, Type CTSS provides the integrated operational, functional, and communication capabilities to meet the requirements of the CTSS and the specified CTSS and Traffic Management System. The Department’s existing Traffic Management System is ▇▇▇▇.▇▇▇. Obtain from the RE the Department’s latest version licenses of ▇▇▇▇.▇▇▇ to cover all installations. Ensure the amount of RAM and Flash memory in the controller, and any module hardware/software, meets the requirements of the CTSS, the ATMS. now System, ATC standard version 6.25 or latest version if approve by the Department, the System Detector System, RSU and the Image Detector System. Coordinate with NJOIT as directed by RE to provide all required documents, licenses, and information for installing or integrating CTSS devices, servers, and workstations on the Department’s network. Submit working drawings that include a block wiring diagram that illustrates the interconnections of the CTSS components from the field location to the designated control center. Also, include a cabinet equipment layout diagram. Identify each component by manufacturer and model number.
Controller, CTSS. At least 30 days before beginning of construction, submit working drawings for approval that include a block diagram and cabinet layout diagram for integration of the existing System Detectors in the applicable traffic signal cabinet back panels, the existing Department Traffic Management System, and the CTSS. Identify each component by manufacturer and model number.
Controller, CTSS. Submit working drawings for approval that include a block wiring diagram that illustrates the interconnections of the CTSS components from the field location to the designated control and data centers, and related network architecture necessary for Adaptive CTSS functionality. Also, include a cabinet equipment layout diagram. Identify each component by manufacturer and model number, and include respective manufacturer documents that verify the component meets the requirements. Ensure the working drawings address all components to be integrated with the controller assembly, including any detection and communication systems a. Setup of intersection parameters, coordination parameters, system parameters, and graphics including all GIS shape files and aerials b. Configuration of control operations and coordination c. Development of intersection operational databases d. Configuring and programming local traffic controllers e. Inputting the timing plans into the CTSS software and traffic controller software to be utilized as a fallback backup for intersections that are not running in the adaptive mode f. Field modifications to timing plans, based on Adaptive System configuration g. Integration of the CTSS server, workstations and local traffic controllers with the communication network h. Integration of the Image Detection units and System Detection units with traffic controller. i. Configuration and calibration of Image Detection units and system j. Configuration and calibration of System Detection units and system k. Integration of the Image Detection server and Image Detection units with the communication network l. Integration of the System Detection server and System Detection units with the communication network m. Integration of the Roadside Units if specified under 704.03.14

Related to Controller, CTSS

  • Data Controller The Sponsor shall be the data controller for such personal data except that, if Quintiles deals with any personal data under this Agreement in the manner of a data controller, Quintiles shall be the data controller of such personal data to the extent of such dealings. Quintiles may process "personal data", as defined in the applicable data protection legislation enacted under the same or equivalent/similar national legislation (collectively "Data Protection Legislation"), of the Investigator and Study Staff for study-related purposes and all such processing will be carried out in accordance with the Data Protection Legislation.

  • Other Controller Audit Any other Controller may audit SAP’s control environment and security practices relevant to Personal Data processed by SAP in line with Section 5.1 only if any of the cases set out in Section 5.1 applies to such other Controller. Such audit must be undertaken through and by Customer as set out in Section 5.1 unless the audit must be undertaken by the other Controller itself under Data Protection Law. If several Controllers whose Personal Data is processed by SAP on the basis of the Agreement require an audit, Customer shall use all reasonable means to combine the audits and to avoid multiple audits.

  • Controller The Controller shall be the chief accounting officer of the Company. He shall keep full and accurate accounts of the assets, liabilities, commitments, receipts, disbursements and other financial transactions of the Company; shall cause regular audits of the books and records of account of the Company and supervise the preparation of the Company’s financial statements; and, in general, he shall perform the duties incident to the office of controller of a company (as if the Company were a Delaware corporation) and such other duties as may be assigned to him by the Member or the President or as may be provided by law. If no Controller is elected by the Member, the Treasurer shall perform the duties of the office of controller.

  • Department Chairs The release time required to perform the administrative functions of the Department Chair positions shall be deducted from the total workload of the Department Chair with no less than fifty percent (50%) of this release taken from direct instructional duties.

  • Data Integrity Control Personal Data will remain intact, complete and current during processing activities.