Demising Walls. Landlord and Tenant shall equally bear the cost of demising walls affecting the Premises. EXHIBIT J BUILDING STANDARD MATERIALS/SPECIFICATIONS A. DOORS, FRAMES & HARDWARE TENANT SUITE ENTRY AND EGRESS DOORS Solid core maple veneer doors in a maple frame with 1'6" X 8'0" sidelight and building standard hardware. Door shall be full height 3'0" X 8'0" X 1 3/4" INTERIOR DOOR Solid core maple veneer doors in a pressed metal frame with building standard hardware. Door shall be full height 3'0" x 8'0" x 1 3/4". STAIN Stain veneer to match architect's (base building) sample. Landlord shall provide a stain veneer sample to Tenant's designer within ten (10) days after execution of the Lease. ENTRY AND EGRESS DOOR HARDWARE _______________________- full mortise, lever dead latch lockset with surface mounted ADA closer, two pair of heavy weighted hinges, Ives door stop and silencer. Metal shall be US 26 Polished Chrome or US32 polished stainless steel. Landlord shall provide the complete desired door hardware specification to Tenant within ten (10) days after execution of the Lease. INTERIOR DOOR HARDWARE Lever hardware with two pair of heavy weight hinges, Ives door stop and silencer. B. BUILDING SAFE FIRE PROTECTION Hydraulically designed, light hazard wet sprinkler system throughout all common and tenant areas. Heads shall be concealed phantom type heads recessed in ceiling and centered in the 2' x 2' ceiling tile. The underground garage will be protected by a dry type sprinkler system. SMOKE DETECTORS, HEAT DETECTORS, REMOTE LED'S Smoke or heat detectors will be installed, where required using CPD-ID module 301-ID by Fire Control Instruments. FIRE ALARM HORN/STROBE Fire alarm strobes will be installed, where required. C. CEILING 117 ACOUSTICAL TILE Acoustic ceiling tile shall be VSG Acoustical Frost 414 with 2' x 2' x 5/8" thick tegular edge. Tenant shall have the right to use an alternate ceiling specification in certain areas of the Premises, subject to Landlord's reasonable approval thereof. SUSPENSION GRID Grid shall be Chicago Metallic 716 white ceiling grid CEILING HEIGHTS 13'8" - slab to slab 9'6" - finished ceiling height in tenant space D. FLOOR COVERINGS CARPET Cut pile option: 32 o▇▇▇▇ "▇▇▇▇▇▇ ▇▇▇▇▇ ▇▇" ▇▇ Shaws; or Loop pile option: 28 ounce "Colonial" by Shaws VINYL COMPOSITION TILE 12" x 12" tile by Arms▇▇▇▇▇ ▇▇▇ndard Excelon Base 4" high resilient base by Nafco or Ropp▇ ▇. PARTITIONS DEMISING PARTITION Framed with 3 5/8", 25 gage metal studs on 16" centers. Partitions shall have one layer of 5/8" gypsum wall board, each side, taped and sanded. Cavity shall have mineral BATT insulation and meet or exceed the Underwriters Laboratory Design U448. Partition shall extend from floor to deck and be sealed, top and bottom. 118 EXHIBIT K CLEANING SPECIFICATIONS
Appears in 2 contracts
Sources: Lease Agreement (Firepond Inc), Lease Agreement (Firepond Inc)