Common use of Developer Responsibilities Clause in Contracts

Developer Responsibilities. DEVELOPER agrees to: I. Provide the Building Official with notice of a minimum of three (3) working days prior to any public event in which the intent is to have the Doors in the open position. II. Provide the Building Official an Inspection Report, as described below on the first working day after any public event in which the Doors are open. a. This Inspection Report for the Doors shall contain the following information: i. Date & time of the report. ii. Report title – “LV Stadium Operable Door Report.” iii. Name & title of individual preparing the report. iv. Forecasted maximum wind speed, actual maximum wind speeds and weather station locations used in determining if the Doors were to remain open or not. v. Actual wind speeds reports at the various weather stations identified in the Doors AMMR. vi. Decisions and actions taken based on data, including names and title of individuals involved in the decision process outlined in the Doors AMMR. III. Provide the Building Official with notice of a minimum of three (3) working days prior to any public event which occurs immediately following the retraction of the Columns. IV. Arrange for the inspection of the Columns to assure that the Columns are fully repositioned and engaged prior to the general public occupying the concourse and seating bowl areas supported by the Columns. a. The costs of the inspection shall be the responsibility of the DEVELOPER. b. The inspection may be performed by either an approved Quality Assurance Agency or by a CCDBFP inspector. If an inspection is conducted by a CCDBFP inspector, the cost shall be based on the actual time of the inspection at the published hourly inspection rate at the time of the inspection and shall be paid within 30 days following the inspection. Should a Building Official or inspector complete an inspection, all reports related to the inspection shall be provided promptly to the DEVELOPER. V. Provide the Building Official with an inspection report certifying that all retractable Columns are fully repositioned and engaged prior to the general public occupying the concourse. This inspection report must be submitted the following work day. a. The inspection report for the Columns shall contain the following information: i. Date & time of the inspection. ii. Name & title of individual performing the inspection. iii. Title of inspection report “LV Stadium Retractable Column Report”. iv. The means and method of the inspection. v. Results of the Inspection. b. If a CCDBFP inspector performs the inspection, the CCDBFP shall provide the DEVELOPER with such a report submitted to the DEVELOPER the following day. VI. The DEVELOPER agrees that in the event that the Doors and Columns inspection reports required to be provided by the DEVELOPER as described above are not submitted to the Building Official as required or that the reports are incomplete, then COUNTY may require that the inspection of the Doors and Columns be performed only by CCDBFP Inspectors for all events.

Appears in 2 contracts

Sources: Operations Agreement, Las Vegas Stadium Door and Columns Operations Agreement

Developer Responsibilities. DEVELOPER agrees Agrees to: I. Provide the Building Official with notice of a minimum of three (3) working days prior to any public event in which the intent is to have the Doors in the open position. II. Provide the Building Official an Inspection Reportinspection report, as described below on the first working day after any public event in which the Doors are open or were intended to be open. a. This Inspection Report inspection report for the Doors shall contain the following information: i. Date & time of the report. ii. Report title – “LV Stadium Operable Door Report.” iii. Name & title of individual preparing the report. iv. Forecasted maximum wind speed, actual maximum wind speeds and weather station locations used Used in determining if the Doors doors were to remain open or not. v. Actual wind speeds reports at the various weather stations identified in the Doors AMMRAMMRs. vi. Decisions and actions taken based on data, including names and title of individuals involved in the decision process outlined outline in the Doors AMMR. III. Provide the Building Official with notice of a minimum of three (3) working days prior to retracting the Columns at any public event which occurs immediately following the retraction of the Columnstime. IV. Arrange for the inspection of the Columns to assure that the Columns are fully repositioned and engaged prior to the general public occupying the concourse and seating bowl areas supported by the Columns. a. The costs of the inspection shall be the responsibility of the DEVELOPER. b. The inspection may be performed by either an approved Quality Assurance Agency or by a CCDBFP inspector. If an inspection is conducted by a CCDBFP CCCDBFP inspector, the cost shall be based on the actual time of the inspection at the published hourly inspection rate at the time of the inspection and shall be paid within 30 days following in advance of the inspection. Should a Building Official or inspector complete an inspection, all reports related to the inspection shall be provided promptly to the DEVELOPER. V. Provide the Building Official with an inspection report certifying that all retractable Columns columns are fully repositioned and engaged prior to the general public occupying the concourseconcourse and that the seating bowl areas supported by the Columns are, in total or in part, fully or partially retracted. This inspection report must be submitted the following work day. a. The inspection report for the Columns shall contain the following information: i. Date & time of the inspection. ii. Name & title of individual performing the inspection. iii. Title of inspection report “LV Stadium Retractable Column Report”. iv. The means and method of the inspection. v. Results of the Inspection. b. If An inspection report is not required if a CCDBFP inspector performs the inspection, the CCDBFP shall provide the DEVELOPER with such a report submitted to the DEVELOPER the following day. VI. The DEVELOPER agrees that in the event that the Doors and Columns inspection reports required to be provided by the DEVELOPER as described above are not submitted to the Building Official as required or that the reports are incomplete, then the COUNTY may require that the inspection of the Doors and Columns be performed only by CCDBFP Inspectors for all events.

Appears in 1 contract

Sources: Operations Agreement