Devices and variables Clause Samples

Devices and variables. The VK used in this study was the Keratograph 5M system (Oculus, Optikgerate, Germany), which provides a measure of the non-invasive break-up time (NIBUT) by means of detecting perturbations of the ▇▇▇▇▇▇▇ rings projected on the tear film. Each subject was asked to maintain the eyes opened after blinking two times in a low-light room (1 lux) during the measure with infrared light. For some subjects, the blink can terminate the measurement before a potential break-up of the tear film. In cases like these, the trial was repeated if the system provided the message “too short time” or was accepted, classifying the tear film as stable and recording the blinking time (BT). In the remaining cases, the system provided two variables, the first (NIBUT) and the mean (MNIBUT) non-invasive break-up times. The MNIBUT was calculated considering all broken segments and the stability was classified in a grade scale as stable (level 0: break-up average ≥14s), critical (level 1: break-up average ≥7 bis <14s) or unstable (level 2: break-up average <7s). For uniform classification of ordinal variables with the OQAS, level 0 was considered as grade 1 in this study, and consequently grades with this device were the level offered by the manufacturer plus one (grade = level + 1). The double pass system used was the OQAS HD Analyzer (Visiometrics SL, Terrassa, Spain) which provides a measurement of the optical effect of tear film instability using the double-pass retinal images of a point source and calculating the Ocular Scattering Index (OSI).[12] During the measurement, the subject's refractive error was corrected internally by an optometer (ranging from −8.00 to +5.00 diopters [D] in the instrument) prior to the OSI tear film measurement. Besides that, astigmatism above 0.50 D was corrected using trial lenses. Measurements were taken in a low light room (5 lux) different from the VK. The system allowed the clinician to obtain three types of measures: (1) without blinking (2) after blinking each 3 seconds, “baseline mode” and (3) after blinking each 9 seconds, “stress mode”. With these three measurement modes, the system recorded double-pass images every 0.5 seconds during a 20-second period. Thus, the system recorded 40 images showing the evolution of the eye optical quality during the 20 seconds of measurement. The procedure used in the current study was the “baseline mode”, with the patient blinking each 3 seconds after a beep emitted by the device. The variables provided by ...

Related to Devices and variables

  • Elections and Variables Security Interest for “Obligations”. The term “Obligations” as used in this Annex includes the following additional obligations: With respect to Party A: None. With respect to Party B: None.

  • Processes Any employer, employee, trade union or employer’s association may at any point in time apply for an exemption from any of the provisions of this Collective Agreement. The applicant is required to complete and submit in writing with the relevant office of the Council, a fully and properly completed prescribed application for exemption form, accompanied by all relevant supporting documentation.

  • Interfaces GTE provides the CLECs with choices for access to OSS pre-ordering, ordering, maintenance and repair systems. Availability of the interfaces is fundamental to the CLEC being able to effectively do business with GTE. Additionally, in many instances, CLEC personnel must work with the service personnel of GTE. Measurements in this category assess the availability to the CLECs of systems and personnel at GTE work centers.

  • Details of Data Processing (a) Subject matter: The subject matter of the data processing under this DPA is the Customer Data.

  • Data The statistical, industry-related and market-related data included in the Registration Statement and the Prospectus are based on or derived from sources which the Company reasonably and in good faith believes are reliable and accurate, and such data agree with the sources from which they are derived. The Company has obtained the written consent to the use of such data from such sources to the extent necessary.