ELECTRICAL POINTS Clause Samples

The 'Electrical Points' clause defines the allocation, installation, and specification of electrical outlets, switches, and related fixtures within a property or project. It typically outlines the number, type, and locations of these points, as well as the standards or codes they must meet. This clause ensures that both parties have a clear understanding of the electrical infrastructure to be provided, preventing disputes over adequacy or placement and ensuring compliance with safety and regulatory requirements.
ELECTRICAL POINTS. Bed rooms : Two light points, one fan point, one multi- plug point (5 Amps) computer points in all bed rooms, only one washing point. Toilets : One light point, one exhaust fan point, 15 Amps, one Geyser point. Living/Dining Room: Two light points, two fan points, one plug point (15 Amps), one T.V. Point and one Refrigerator point.
ELECTRICAL POINTS. (a) Bed Rooms – 2 Light points, 1 Fan points, One 5 Amp. Socket. (b) Dining cum Drawing Room - 3 Light points, 2 Fan points, One 15 Amp. Socket, 1 T.V.
ELECTRICAL POINTS. A. As per electrical drawings and to architects detail.
ELECTRICAL POINTS. Bed rooms - Four light points, one fan point, one plug point (6 Amps), Toilets - One light point, one exhaust fan point, 15 Amps Geyser point (in one toilet) Living/Dining Room - three light points, one fan points, one plug point (6 Amps), one T.V. Point and one Refrigerator point (15 AMP) Kitchen - two light point, one Water filter point and exhaust point and one 15 Amps Microwave point. Stairs/ Common Gallery- One light point in each landing, One bell Point outside of every flat. One plug point (6 Amps) in the balcony. The Purchaser has to pay extra money for any extra work other than what are stated in hereto.
ELECTRICAL POINTS. Telephone connection + 6 ply wiring (Tenant will order the telephone lines).
ELECTRICAL POINTS. A Concealed Copper wiring B Semi modular switches of reputed brand. Calling Bell SWITCH BOARD OUTSIDE THE MAIN DOOR Living-dinning Fan Point, Light Point, TV Point, Cable TV Point, Intercom Point, Phone Point, Distribution Box Kitchen Fridge Point, Exhaust Fan point, Light point, fan point, Aquagurad point Master Bedroom Fan Point, Light Point, TV Point, Cable TV Point, Phone Point, Plug point Other Bedrooms Fan Point, Light Point, Plug point Attached Toilet Exhaust fan Point, Light Point, Geyser Point, Plug point Common Toilet Exhaust fan Point, Light Point, Plug point HVAC Point One point on all Bedrooms Balcony One ceiling Light Point Washing Machine One Point • Badminton court • Indoor Games room • Landscape Garden • Kids play zone • Adda zone • 24 hours water supply • 24 hour Power back-up ALL THAT APARTMENT/UNIT, bearing No. , on the FLOOR in BLOCK NO. , measuring about 590 sq. ft. super built-up area, in the residential building complex named and known as "MAGNOLIA ▇▇▇▇▇▇▇" ALONG WITH undivided proportionate share, right, title and interest in the land underneath the building on which the flat is situated, forming part of the said Land together with common rights in the common areas and facilities of the said building/building complex/said Land. One __________ car parking space being No. ________, measuring __________
ELECTRICAL POINTS. AMENITIES Extras & Deposits:

Related to ELECTRICAL POINTS

  • Electrical Power Corporation shall provide Contractor with convenient access to electrical power required to perform the work. The electrical outlets used by Contractor shall be those designated or approved by Corporation.

  • Electrical Items All electrical items purchased under this Grant Agreement/Contract or used in the performance of approved and eligible grant-funded activities must meet all applicable Occupational Safety and Health Administration (OSHA) standards and regulations, and bear the appropriate listing from Underwriters Laboratory (UL), Factory Mutual Resource Corporation (FMRC), or National Electrical Manufacturers Association (NEMA).

  • Electrical Equipment Residents must use only CSA, UL-approved or Canadian-certified electrical equipment; the rated wattage of light fixtures must never be exceeded; and only replacement bulbs supplied by Waterloo maintenance staff may be used. Do not leave any unattended electrical equipment turned on (i.e. hair straighteners, lights etc.)

  • ELECTRICAL SERVICES The Company must construct and reticulate electrical requirements for all amenities and facilities. The Company must construct sub-station and distribution boards necessary to reticulate power to all Company owned or leased facilities which provide amenities to the public. The electrical installation must be to the design and installation standards of the State Energy Commission of Western Australia. All electrical reticulation must be placed underground.

  • Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 ▇▇▇▇▇ per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts.