Excess Generation. 5.6.1 Any excess generation over and above 10% of declared annual PLF will be purchased by MSEDCL at a 75% of the tariff of the successful bidder. The bidder cannot claim REC for these excess generated units as the same shall be accounted for meeting the RPO target of MSEDCL. 5.7 Generation Compensation in offtake constraint due to transmission: 5.7.1 During the operation of the plant, due to temporary transmission unavailability, if the power is not evacuated, for reasons not attributable to bidder, then the generation loss shall be procured by MSEDCL at the PPA tariff to offset loss in 3 years. The Generation Loss shall be computed as Average Generation per hour x number of hours of grid unavailability.