Fire Extinguishing System Sample Clauses

The Fire Extinguishing System clause sets out the requirements for installing and maintaining fire suppression equipment within a property or facility. Typically, it specifies the types of fire extinguishing systems to be used, such as sprinklers or portable extinguishers, and may outline standards for inspection, testing, and compliance with local fire codes. This clause ensures that adequate fire protection measures are in place, thereby reducing the risk of fire damage and enhancing the safety of occupants.
Fire Extinguishing System. From time to time and as often as reasonably required by the Department or any governmental authority having jurisdiction, Tenant shall conduct pressure, water flow, and other appropriate tests of the fire extinguishing system and apparatus, which are maintained by Tenant or any subtenant.
Fire Extinguishing System. Where Sites are not located close to a 24 hours a day, 7 days a week basis security centre allowing rapid intervention of less than 3 minutes in case of fire detection, such Sites will be protected by a halon free extinguishing system (type Argonite, Inergen or other). This system will be connected to a fire detection system which operates automatically after a predetermined time in case of fire detection. The system will generate as a minimum the following alarms which will be remotely monitored by the EGT Network Management Centre: o Fault o Operation
Fire Extinguishing System. The fire extinguishing system will operate automatically by a monitoring system which will operate a sprinkler system on all the areas of the project (parking lots, commercial floors, offices, machine rooms and storage rooms). The project is split into four separate zones for fire fighting: parking and commercial levels round tower, triangle tower, square tower. Each zone will have its own water supply system. A water supply pipe and fire extinguishers are also situated all over the structure.
Fire Extinguishing System. An automated fire extinguishing system controlled by a sophisticated complex control that activates sprinklers throughout the parking areas. Additionally there are water supply pipes and fire extinguishing points throughout as required by the fire department.
Fire Extinguishing System. The electrical installations will be installed in accordance with the strict standards and instructions of the Fire-Fighting Authority, including fire-proof cables for back-up equipment in case of fire, emergency lighting, emergency elevators, exit signboards, etc. A fire detection system will be installed in all the Public Areas with preparation up to the areas of the Leased Premises. An emergency public address system will be installed to cover all the Public Areas with preparation up to the areas of the Leased Premises. A fire extinguisher system will be installed in all the areas at a basic extinguisher level (without flexible piping). A fire-fighting intercom system will be installed. Connections will be installed for activating smoke release, inflation systems, etc. Emergency shut-down systems will be installed as required by the authorities.

Related to Fire Extinguishing System

  • Filing Systems and Equipment A complete and comprehensive catalog of filing systems including vertical and lateral files, bookcases, mobile cabinets and freestanding file cabinets.

  • Functionality Customer is entitled to additional functionality previously purchased or bundled with the software if available in the version or update released on or after the start date of the Agreement. Customer acknowledges that certain functionality in current and previous software versions may not be available in future upgrades. Added functionality may require additional paid services (clinical and technical) to configure and support.

  • Unbundled Network Elements 35.4.1. The charges that CLEC shall pay to Sprint for Unbundled Network Elements are set forth in Table One of this Agreement. 35.5. Collocation 35.5.1. The charges that CLEC shall pay to Sprint for Collocation are set forth in Table Two of this Agreement. 35.6. Call Related Databases 6.1. The charges that CLEC shall pay to Sprint for Call Related Databases purchased pursuant to Part J are set forth in Table One of this Agreement.

  • Sprinkler System TWENTY-SIXTH.--If there now is or shall be installed in said building a "sprinkler system" the Tenant agrees to keep the appliances thereto in the demised premises in repair and good working condition, and if the New York Board of Fire Underwriters or the New York Fire Insurance Exchange or any bureau, department of official of the State or local government requires or recommends that any changes, modifications, alterations or additional sprinkler heads or other equipment be made or supplied by reason of the Tenant's business, or the location of partitions, trade fixtures, or other contents of the demised premises, or if such changes, modifications, alterations, additional sprinkler heads or other equipment in the demised premises are necessary to prevent the imposition of a penalty or charge against the full allowance for a sprinkler system in the fire insurance rate as fixed by said Exchange, or by any Fire Insurance Company, the Tenant will at the Tenant's own expense, promptly made and supply such changes, modifications, alterations, additional sprinkler heads or other equipment. As additional rent hereunder the Tenant will pay to the Landlord, annually in advance, throughout the term $ toward the contract price for sprinkler supervisory service.

  • Customer Equipment “Customer Equipment” means any Customer-owned or provided software, hardware or services that you elect to use in connection with the Service(s). You agree to allow us and our agents the rights to insert CableCARDs and other hardware in the Customer Equipment, send software and/or downloads to the Customer Equipment and install, configure, maintain, inspect and upgrade the Customer Equipment. You warrant you are either the owner of the Customer Equipment or that you have the authority to give us access to the Customer Equipment. You should call Customer Service at ▇-▇▇▇-▇▇▇-▇▇▇▇ to find out if it meets our technical, security and other requirements. We reserve the right to disallow the use of Customer Equipment that we determine is not compatible with our network. We shall have no obligation to provide, maintain, or service Customer Equipment, including, but not limited to, Customer Equipment to which the Company or a third party has sent software or downloads. If you use Customer Equipment, you agree that the following limitation of liability shall apply: THE COMPANY DOES NOT WARRANT THAT CUSTOMER EQUIPMENT WILL ENABLE YOU TO SUCCESSFULLY INSTALL, ACCESS, OPERATE, OR USE THE SERVICE(S). YOU ACKNOWLEDGE THAT ANY SUCH INSTALLATION, ACCESS, OPERATION, OR USE COULD CAUSE CUSTOMER EQUIPMENT TO FAIL TO OPERATE OR COULD CAUSE DAMAGE TO CUSTOMER EQUIPMENT, YOU, YOUR PREMISES OR COMPANY EQUIPMENT. NEITHER THE COMPANY NOR ANY OF ITS AFFILIATES, SUPPLIERS OR AGENTS SHALL HAVE ANY LIABILITY WHATSOEVER FOR ANY SUCH FAILURE OR DAMAGE, INCLUDING LACK OF 911/E911 CAPABILITY OR DIALING ASSOCIATED WITH A SECURITY SYSTEM. YOUR USE OF CUSTOMER EQUIPMENT MAY PREVENT PROVISION OF SERVICE. The foregoing limitation of liability is in addition to and shall not limit any other limitation of liability set forth in this Agreement.