Humidifier Service Clause Samples

Humidifier Service a. Bypass Humidifier 1. Turn water supply on and inspect for leaks. 2. Replace humidifier pad (may be additional cost). 3. Clean any scale build-up on unit. 4. Check/flush drainage pipes. 5. Set humidity control levels. 6. Test operation. 7. Follow manufacturer’s annual service guidelines. b. Steam Humidifier 1. Turn water supply on and inspect for leaks. 2. Replace humidifier steam cartridge (may be an additional cost). 3. Clean any scale build-up on unit. 4. Check/flush drainage pipes and cycle auto drain operation. 5. Inspect steam injection nozzles. 6. Set humidity control levels.

Related to Humidifier Service

  • Electrical Service Electrical service for new construction or a renovated existing building shall be 480/277-volt, 3-phase, 4-wire or approved equal. Service shall be sized for HVAC and other mechanical system(s) loads, lighting, general building services, and dedicated computer based office equipment loads. 5 ▇▇▇▇▇ per square foot shall be provided for lighting and general service receptacles. Size of neutral conductor of 3- phase circuits shall be twice that of phase conductor to accommodate potential harmonic currents associated with computer system electronic power supplies and fluorescent lighting fixtures electronic ballasts.

  • Water Service The Purchase Price for the Property shall include all water rights/water shares, if any, that are the legal source for Seller’s current culinary water service and irrigation water service, if any, to the Property. The water rights/water shares will be conveyed or otherwise transferred to Buyer at Closing by applicable deed or legal instruments. The following water rights/water shares, if applicable, are specifically excluded from this sale:

  • Customer Service A. PRIMARY ACCOUNT REPRESENTATIVE. Supplier will assign an Account Representative to Sourcewell for this Contract and must provide prompt notice to Sourcewell if that person is changed. The Account Representative will be responsible for: • Maintenance and management of this Contract; • Timely response to all Sourcewell and Participating Entity inquiries; and • Business reviews to Sourcewell and Participating Entities, if applicable.

  • Temperature Measurement Temperature will be measured by the nearest automatic Melbourne Bureau of Meteorology Monitoring Station for example (but not limited to): Melbourne, Moorabbin, Dunns Hill, Melbourne Airport, Frankston, and Point ▇▇▇▇▇▇. At the commencement of each project, the onsite management and employee representatives shall agree which is to be the applicable automatic weather monitoring station.

  • CLOUD SERVICE The Cloud Service offering, is described below and is specified in an Order Document for the selected entitled offerings. The Order Document will consist of the Quotation that is provided and the Proof of Entitlement (▇▇▇) you will receive confirming the start date and term of the Cloud Services and when invoicing will commence.