INSTALLATION, GENERAL Clause Samples

The 'INSTALLATION, GENERAL' clause outlines the basic requirements and procedures for installing equipment, materials, or systems under a contract. It typically specifies standards for workmanship, compliance with manufacturer instructions, and adherence to relevant codes or regulations. For example, it may require that all installations be performed by qualified personnel and that the work area be left clean and safe upon completion. The core function of this clause is to ensure that installations are performed correctly and safely, thereby reducing the risk of defects, accidents, or non-compliance with legal standards.
INSTALLATION, GENERAL. A. Locate facilities where they will serve Project adequately and result in minimum interference with performance of the Work. Relocate and modify facilities as required by progress of the Work.
INSTALLATION, GENERAL. A. Conceal cables in finished walls, ceilings, and floors unless otherwise indicated. B. Complete raceway installation between conductor and cable termination points according to Section 260533 "Raceways and Boxes for Electrical Systems" prior to pulling conductors and cables. C. Use manufacturer-approved pulling compound or lubricant where necessary; compound used must not deteriorate conductor or insulation. Do not exceed manufacturer's recommended maximum pulling tensions and sidewall pressure values. D. Use pulling means, including fish tape, cable, rope, and basket-weave wire/cable grips, that will not damage cables or raceway. E. Install exposed cables parallel and perpendicular to surfaces of exposed structural members and follow surface contours where possible. F. Support cables according to Section 260529 "Hangers and Supports for Electrical Systems."
INSTALLATION, GENERAL. A. Locate fencing at the direction of Owner’s designated personnel. B. Temporary panel fencing should be installed on concrete or galvanized steel bases for supporting posts. Sand bags are required if galvanized steel bases are used. C. Install panel clamps to secure temporary panel fencing together.
INSTALLATION, GENERAL. A. Set carpentry to required levels and lines, with members plumb, true to line, cut, and fitted. Fit carpentry to other construction; scribe and cope as needed for accurate fit.
INSTALLATION, GENERAL. A. General: Install roof specialties according to manufacturer's written instructions. Anchor roof specialties securely in place, with provisions for thermal and structural movement. Use fasteners, solder, protective coatings, separators, underlayments, sealants, and other miscellaneous items as required to complete roof-specialty systems. 1. Install roof specialties level, plumb, true to line and elevation; with limited oil-canning and without warping, jogs in alignment, buckling, or tool marks.
INSTALLATION, GENERAL. A. Cold-formed metal framing may be shop or field fabricated for installation, or it may be field assembled. B. Install cold-formed metal framing according to AISI's "Standard for Cold-Formed Steel Framing - General Provisions" and to manufacturer's written instructions unless more stringent requirements are indicated. C. Install cold-formed metal framing and accessories plumb, square, and true to line, and with connections securely fastened. 1. Cut framing members by sawing or shearing; do not torch cut. 2. Fasten cold-formed metal framing members by screw fastening, clinch fastening, or riveting. Wire tying of framing members is not permitted. a. Locate mechanical fasteners and install according to Shop Drawings, and complying with requirements for spacing, edge distances, and screw penetration. D. Do not bridge building expansion and control joints with cold-formed metal framing. Independently frame both sides of joints.
INSTALLATION, GENERAL. A. Install roofing system in accordance with manufacturer’s written instructions and approved details. B. NRCA Installation Details: Install roofing system in accordance with applicable NRCA Manual Plates and NRCA recommendations; modify as required to comply with manufacturer's approved details.
INSTALLATION, GENERAL. A. Install conduit as follows: 1. In complete runs before pulling in cables or wires. 2. Flattened, dented, or deformed conduit is not permitted. Remove and replace the damaged conduits with new undamaged material.
INSTALLATION, GENERAL. A. Set rough carpentry to required levels and lines, with members plumb, true to line, cut, and fitted. Fit rough carpentry to other construction; scribe and cope as needed for accurate fit. Locate nailers, blocking, and similar supports to comply with requirements for attaching other construction. B. Framing Standard: Comply with AF&PA's "Details for Conventional Wood Frame Construction," unless otherwise indicated. C. Framing with Engineered Wood Products: Install engineered wood products to comply with manufacturer's written instructions. D. Metal Framing Anchors: Install metal framing to comply with manufacturer's written instructions.
INSTALLATION, GENERAL. A. Coordinate placement of doors with the work of other trades. B. Comply with manufacturer's written instructions for installing all access doors and hatches.