MEASUREMENT, GAS QUALITY, AND FAILURE TO MEET SPECIFICATIONS Sample Clauses

MEASUREMENT, GAS QUALITY, AND FAILURE TO MEET SPECIFICATIONS. 4.1 Biomethane delivered at the Receipt Point Facilities will be measured by NW Natural measurement equipment installed, operated and maintained at or near the Receipt Point Facilities. The unit of volume for the purpose of measurement will be one (1) cubic foot of gas at a base temperature of 60 °F, and at a base pressure of 14.73 psia. Such measured volumes, converted to Mcf, will be multiplied by their gross heating value per cubic foot and divided by 1,000 to determine dekatherms (Dth) received and delivered hereunder. The unit of energy or thermal units for the purpose of balancing total receipts and deliveries of Biomethane hereunder will be one (1) Dth. The volumes of Biomethane measured hereunder will be computed in accordance with determination of thermal units as specified in the Tariff. 4.2 At Producer’s sole cost and expense, all Biomethane delivered by Producer to NW Natural owned and operated facilities will conform to the quality specifications set forth in the Biomethane Quality Specification attached hereto in Exhibit D and made a part hereof. 4.3 If there are multiple quality monitoring devices providing information for the same constituents, the one(s) maintained by NW Natural will be the official measurement source. 4.4 NW Natural may request a deviation from the monitoring equipment and interval requirements where additional measures are necessary to provide reliable service in a safe environment.
MEASUREMENT, GAS QUALITY, AND FAILURE TO MEET SPECIFICATIONS. 4.1 Biomethane delivered at the Receipt Point Facilities shall be measured by NW Natural measurement equipment installed, operated and maintained at or near such Receipt Point Facilities. The unit of volume for the purpose of measurement shall be one (1) cubic foot of gas at a base temperature of 60 °F, and at a base pressure of 14.73 psia. Such measured volumes, converted to Mcf, shall be multiplied by their gross heating value per cubic foot and divided by 1,000 to determine dekatherms (Dth) received and delivered hereunder. The unit of energy or thermal units for the purpose of balancing total receipts and deliveries of Biomethane hereunder shall be one (1) Dth. The volumes of Biomethane measured hereunder shall be computed in accordance with determination of thermal units as specified in the Tariff. NW Natural will perform regular calibration procedures on its measurement equipment at intervals consistent with industry standards and NW Natural will share data from this calibration with Producer at Producer’s request. Shell shall install its own biomethane measurement equipment; and, to the extent NW Natural’s equipment is out of operation, Shell’s measurement equipment will be used in lieu of NW Natural’s equipment to perform the measurement required under this Section 4.1. 4.2 At Producer’s sole cost and expense, all Biomethane delivered by Producer to NW Natural owned and operated facilities shall conform to the quality specifications set forth in the Biomethane Quality Specification attached hereto in Exhibit D and made a part hereof. 4.3 If there are multiple quality monitoring devices providing information for the same constituents, the one(s) maintained by NW Natural will be the official measurement source. 4.4 NW Natural may request a deviation from the monitoring equipment and interval requirements where additional measures are necessary to provide reliable service in a safe environment.

Related to MEASUREMENT, GAS QUALITY, AND FAILURE TO MEET SPECIFICATIONS

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Meteorological Data Reporting Requirement (Applicable to wind generation facilities only)

  • Technical Specifications The purpose of the Technical Specifications (TS), is to define the technical characteristics of the Goods and Related Services required by the Procuring Entity. The Procuring Entity shall prepare the detailed TS consider that:

  • Data Quality 4.1 Each party ensures that the shared Personal Data is accurate. 4.2 Parties will notify each other with undue delay if they become aware of inaccuracies in shared Personal Data.